n Features:
Ø High AC input:176VAC~265VAC
Ø High Efficiency, and High reliability
Ø Output protections: SCP/OVP/OPP/OLP
Ø Wide operating ambient temperature (-10℃~50℃)
Ø All using 105℃ long life electrolytic capacitors.
Ø 100% full load burn-in test
Ø 2 years warranty
SPECIFICATION
|
MODEL
|
GZM-H100D5+12
|
|
OUTPUT
|
Ouput Number
|
V1
|
V2
|
|
DC Output
|
5.0V
|
12.0V
|
|
Rated Current
|
10.0A
|
4.0A
|
|
Current Range Note 1
|
0 ~10.0A
|
0 ~4.0A
|
|
Ripple and Noise Note 2
|
0~65℃
|
120mV
|
120mV
|
|
-25~0℃
|
240mV
|
240mV
|
|
Voltage Accuracy
|
±1.0%
|
±10.0%
|
|
Line Regulation
|
±0.5%
|
±1.0%
|
|
Load Regulation
|
±3.0%
|
±10.0%
|
|
Set-up Time
|
<1.0S (220Vac input, Full load)
|
|
Hold up Time
|
>20mS(220Vac input, Full load)
|
|
Temperature Coefficient
|
±0.03%/℃
|
±0.03%/℃
|
|
Overshoot and Undershoot
|
<5.0%
|
|
INPUT
|
Voltage Range
|
176Vac~264Vac
|
|
Frequency Range
|
47Hz-63Hz
|
|
Efficiency ( Typical)
|
75%@220Vac,
|
|
AC Current (max.)
|
2.0A
|
|
Inrush Current (Typical)
|
50A@220Vac Cold start
|
|
Leakage Current
|
Input—Output: ≤0.25mA Input—PG: ≤3.5mA
|
|
PROTECTION
|
Over Power
|
105%~150% of rated output current, auto recovery
|
|
Over Current
|
V1:110%~220% of rated output current, auto recovery
|
|
Over Voltage
|
V1:105%~150% of rated output voltage, auto recovery
|
|
Shorted Circuit
|
Long-time; auto recovery
|
|
ENVIRONMENT
|
Operating amb.Temp.& Hum.
|
-10℃~50℃; 20%~90%RH No condensing
|
|
Storage Temp. & Hum.
|
-30℃~85℃; 10%~95%RH No condensing
|
|
SAFETY &EMC
(Note 3)
|
Safety Standards
|
GB4943-2001; EN60950-1:2006
|
|
Withstand Voltage
|
Primary-Secondary:1.5KVac;≤10mA.Primary-PG:1.5KVac;≤10mA.Secondary-PG:0.5KVDC;≤10mA.
|
|
Isolation Resistance
|
≥100M ohms
|
|
EMI Conduction&Radiation
|
Compliance to EN55022(GB9254)ClassB
|
|
Harmonic Current
|
Compliance to EN61000-3-2,ClassA
|
|
EMS Immunity
|
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA
|
|
OTHERS
|
MTBF (MIL-HDBK-217F)
|
More than 200,000Hrs (25℃, Full load)
|
|
Dimension (L*W*H)
|
199×98×40mm
|
|
Cooling method
|
Cooling by free air convection
|
|
NOTE
|
1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor.
3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
|
|