CMG-H150D

n         Features:

Ø         High Efficiency, and High reliability

Ø         Output protections: SCP/OVP/OPP/OLP

Ø         Wide operating ambient temperature (-10~50)

Ø         All using 105 long life electrolytic capacitors.

Ø         100% full load burn-in test

Ø         2 years warranty     

Ø         Isolated Dual Outputs

SPECIFICATION                                                      

MODEL

CMG-H150D12G+24

CMG-H150D24G+12

OUTPUT

DC Output

V1

12.0V

24.0V

V2

24.0V

12.0V

Rated Current

V1

5A

6A        Note 2

V2

6A       Note 1

5A

Current Range  Note 3

V1

0.5~5.0A

0~6.0A

V2

0.6~6.0A

0~5.0A

Ripple and Noise Note4

0~65

V1

120mV

240mV

V2

240mV

120mV

Ripple and Noise

-25~0

V1

240mV

480mV

V2

480mV

240mV

Voltage ADJ.  Range

11.4V~12.6V

22.8V~25.0V

Voltage Accuracy

V1

±1.0%

±1.0%

V2

±10.0%

±10.0%

Line Regulation

V1

±0.5%

V2

±1.0%

Load Regulation

V1

±3.0%

V2

±10.0%

Set-up Time

1.0S (230Vac input, Full load)

Hold up Time

20mS(230Vac input, Full load)

Temperature Coefficient

±0.03%/℃

Overshoot and Undershoot

<5.0%

INPUT

Voltage Range  

176Vac~264Vac

Frequency Range

47Hz--63Hz

Efficiency ( Typical)

80%

80%

AC Current (max.)

2.0A/176VAC

Inrush Current (Typical)

50A@220Vac      Cold start

Leakage Current

Input—output:<0.25mA     Input—PG:<3.5mA

PROTECTION

Over Power

105%~150% of rated output current, auto recovery

Over Current

V1

110%~220%   

Auto recovery

110%~150%   

Auto recovery

Over Voltage

V1: 110%~150% of rated output voltage, auto recovery

Shorted Circuit

Long-term mode, auto recovery

ENVIRONMENT

Operating amb. Temp. & Hum.

-10℃~50℃;  20%~90%RH  No condensing

Storage Temp. & Hum.

-30℃~85℃;  10%~95%RH  No condensing

SAFETY &EMC  

(Note 5)

Safety Standards

GB4943-2001; EN60950-12006

Withstand Voltage

Primary-Secondary:3.0KVac; 10mA .Primary-PG:1.5KVac; 10mA.

Secondary-PG:0.5KVDC;10mA.  Output V1—V2: 0.5KVDC;10mA. Test time:1 min

Isolation Resistance

100M ohms

EMI Conduction&Radiation

Compliance to EN55022(CISPR22)ClassB

Harmonic Current

Compliance to EN61000-3-2,17625.1-2003

EMS Immunity

Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA

OTHERS

MTBF (MIL-HDBK-217F)

More than 100,000Hrs (25℃, Full load)

Dimension  (L*W*H)

199×98×40mm

Packing

0.75Kg/pcs,20PCS/CTN, 15KGS.

Cooling method

Cooling by free air convection

 

NOTE

1.     CMG-H150D12G+24 Total output power can’t exceed 150W, Label is marked by the Max current. Recommend the loading is 12V/5A,24V/3.75A.  

2.     CMG-H150D24G+12Total output power can’t exceed 150W, Label is marked by the Max current. Recommend the loading is 24V/5A,12V/3.0A. 

3.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.

4.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.

5.        The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.