MODEL
|
CMG-H150D12G+24
|
CMG-H150D24G+12
|
|
OUTPUT
|
DC Output
|
V1
|
12.0V
|
24.0V
|
|
V2
|
24.0V
|
12.0V
|
|
Rated Current
|
V1
|
5A
|
6A Note 2
|
|
V2
|
6A Note 1
|
5A
|
|
Current Range Note 3
|
V1
|
0.5~5.0A
|
0~6.0A
|
|
V2
|
0.6~6.0A
|
0~5.0A
|
|
Ripple and Noise Note4
0~65℃
|
V1
|
120mV
|
240mV
|
|
V2
|
240mV
|
120mV
|
|
Ripple and Noise
-25~0℃
|
V1
|
240mV
|
480mV
|
|
V2
|
480mV
|
240mV
|
|
Voltage ADJ. Range
|
11.4V~12.6V
|
22.8V~25.0V
|
|
Voltage Accuracy
|
V1
|
±1.0%
|
±1.0%
|
|
V2
|
±10.0%
|
±10.0%
|
|
Line Regulation
|
V1
|
±0.5%
|
|
V2
|
±1.0%
|
|
Load Regulation
|
V1
|
±3.0%
|
|
V2
|
±10.0%
|
|
Set-up Time
|
<1.0S (230Vac input, Full load)
|
|
Hold up Time
|
>20mS(230Vac input, Full load)
|
|
Temperature Coefficient
|
±0.03%/℃
|
|
Overshoot and Undershoot
|
<5.0%
|
|
INPUT
|
Voltage Range
|
176Vac~264Vac
|
|
Frequency Range
|
47Hz--63Hz
|
|
Efficiency ( Typical)
|
80%
|
80%
|
|
AC Current (max.)
|
2.0A/176VAC
|
|
Inrush Current (Typical)
|
50A@220Vac Cold start
|
|
Leakage Current
|
Input—output:<0.25mA Input—PG:<3.5mA
|
|
PROTECTION
|
Over Power
|
105%~150% of rated output current, auto recovery
|
|
Over Current
|
V1
|
110%~220%
Auto recovery
|
110%~150%
Auto recovery
|
|
Over Voltage
|
V1: 110%~150% of rated output voltage, auto recovery
|
|
Shorted Circuit
|
Long-term mode, auto recovery
|
|
ENVIRONMENT
|
Operating amb. Temp. & Hum.
|
-10℃~50℃; 20%~90%RH No condensing
|
|
Storage Temp. & Hum.
|
-30℃~85℃; 10%~95%RH No condensing
|
|
SAFETY &EMC
(Note 5)
|
Safety Standards
|
GB4943-2001; EN60950-1:2006
|
|
Withstand Voltage
|
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA.
Secondary-PG:0.5KVDC;≤10mA. Output V1—V2: 0.5KVDC;≤10mA. Test time:1 min
|
|
Isolation Resistance
|
≥100M ohms
|
|
EMI Conduction&Radiation
|
Compliance to EN55022(CISPR22)ClassB
|
|
Harmonic Current
|
Compliance to EN61000-3-2,17625.1-2003
|
|
EMS Immunity
|
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA
|
|
OTHERS
|
MTBF (MIL-HDBK-217F)
|
More than 100,000Hrs (25℃, Full load)
|
|
Dimension (L*W*H)
|
199×98×40mm
|
|
Packing
|
0.75Kg/pcs,20PCS/CTN, 15KGS.
|
|
Cooling method
|
Cooling by free air convection
|
|
NOTE
|
1. CMG-H150D12G+24 Total output power can’t exceed 150W, Label is marked by the Max current. Recommend the loading is 12V/5A,24V/3.75A.
2. CMG-H150D24G+12Total output power can’t exceed 150W, Label is marked by the Max current. Recommend the loading is 24V/5A,12V/3.0A.
3. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.
4. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
5. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
|