产品展示
PDF-100

Features:

Ø         Universal AC input/ Full range

Ø         Built-in active PFC function, PF>0.93

Ø         High Efficiency, and High reliability

Ø         Output protections: OLP/OVP/SCP

Ø         All using 105℃ long life electrolytic capacitors.

Ø         100% full load burn-in test

Ø         3 years warranty     

 

 

SPECIFICATION                                                      

MODEL

PDF-100-5

PDF-100-12

PDF-100-15

PDF-100-24

PDF-100-48

OUTPUT

DC Output

5.0V

12V

15V

24V

48V

Rated Current

20A

8.5A

6.7A

4.2A

2.15A

Current Range     Note 1

0~20A

0~8.5A

0~6.7A

0~4.2A

0~2.15A

Ripple and Noise   Note 2

100mV

100mV

100mV

150mV

250mV

Voltage ADJ.  Range

4.0V~5.9V

10V~14V

13.5V~17.0V

20V~28V

43V~55V

Voltage Accuracy

±2.0%

±2.0%

±2.0%

±1.0%

±1.0%

Line Regulation

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load Regulation

±1.0%

±0.5%

±0.5%

±0.5%

±0.5%

Set-up Time

2.0S (230Vac input, Full load)

Hold up Time

20mS(230Vac input, Full load)

Temperature Coefficient

±0.03%/℃

Overshoot and Undershoot

<5.0%

INPUT

Voltage Range  

85Vac~264Vac 120~370VDC

Frequency Range

47Hz--63Hz

Power Factor(Typical)

PF0.98/115VAC    PF0.93/230VAC

Efficiency ( Typical)

120Vac input

78%

83%

83%

83%

84%

230Vac input

80%

85%

85%

86%

87%

AC Current (max.)

1.7A/115VAC  0.8A/230VAC

Inrush Current (Typical)

50A@230Vac      Cold start

Leakage Current

Input—output:<0.25mA     Input—PG:<3.5mA

PROTECTION

Over Load

105%~150% of rated output current, hiccup mode, auto recovery

Over Voltage

110%~150% of rated output voltage, shut down

Short Circuit

Long-term mode, auto recovery

ENVIRONMENT

Operating amb. Temp. & Hum.

-10℃~60℃;  20%~90%RH  No condensing(refer to the derating curve)

Storage Temp. & Hum.

-20℃~85℃;  10%~95%RH  No condensing

SAFETY &EMC  

(Note 3)

Safety Standards

UL60950-1; EN60950-12006

Withstand Voltage

Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA.

Isolation Resistance

≥100M ohms

EMI Conduction&Radiation

Compliance to EN55022(CISPR22)ClassB

Harmonic Current

Compliance to EN61000-3-2,17625.1-2003

EMS Immunity

Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA

OTHERS

MTBF (MIL-HDBK-217F)

More than 100,000Hrs (25℃, Full load)

Dimension  (L*W*H)

194×99×50mm

Packing

20PCS/CTN. G.W: 15.2kgs

Cooling method

Cooling by free air convection

 

NOTE

1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.

2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.

3.  The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.