产品展示
PDF-320

n         Features:

Ø         Universal AC input/ Full range

Ø         High Efficiency, and High reliability

Ø         Output protections: OLP/OTP/OVP/SCP

Ø         Wide operating ambient temperature (-20~65)

Ø         All using 105 long life electrolytic capacitors.

Ø         100% full load burn-in test

Ø         3 years warranty   

 

SPECIFICATION                                                      

MODEL

PDF-320-5

PDF-320-7.5

PDF-320-12

PDF-320-24

PDF-320-32

PDF-320-36

PDF-320-48

OUTPUT

DC Output

5.0V

7.5V

12V

24V

32V

36V

48V

Rated Current

60A

40A

25A

13A

10A

8.8A

6.7A

Current Range     Note 1

0~60A

0~40A

0~25A

0~13A

0~10A

0~8.8A

0~6.7A

Ripple and Noise

Note 2

0-65℃

150mV

150mV

150mV

150mV

200mV

200mV

240mV

-20℃

180mV

150mV

150mV

150mV

200mV

200mV

240mV

Voltage ADJ.  Range

±10% of rated output voltage

Voltage Accuracy

±2.0%

±2.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

Line Regulation

±0.5%

±0.5%

±0.3%

±0.5%

±0.2%

±0.2%

±0.2%

Load Regulation

±1.0%

±1.0%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Set-up Time

1.2S (230Vac input, Full load), 2.5S (115Vac input, Full load)

Hold up Time

5V14mS  7.5V/15V/24V/32V/36V/48V16mS/ (230Vac input, Full load)

Temperature Coefficient

±0.05%/℃

Overshoot and Undershoot

<5.0%

INPUT

Voltage Range  

88Vac~264Vac

Frequency Range

47Hz--63Hz

Power Factor(Typical)

PF0.98/115VAC    PF0.93/230VAC

Efficiency ( Typical)

79%

83%

86%

87%

87%

87%

88%

AC Current (max.)

4.0A

Inrush Current (Typical)

<45A@230Vac   <23A@115Vac      Cold start

Leakage Current

Input—output: 0.1mA     Input—PG: 0.75mA

PROTECTION

Over Load

105%~135% of rated output current, hiccup mode,auto recovery

Over Temperture

85+5(detect on heatsink of power transistor);shut down,auto recovery after the temperature goes down

Over Voltage

110%~150% of rated voltage; Shut down

Short Circuit

Long-term mode, auto recovery

ENVIRONMENT

Operating amb. Temp. & Hum.

-20℃~65℃;  20%~90%RH  No condensing

Storage Temp. & Hum.

-40℃~85℃;  10%~95%RH  No condensing

SAFETY &EMC   

(Note 3)

Safety Standards

GB4943-2001; EN60950-12006

Withstand Voltage

Primary-Secondary:3.0KVac; 10mA .Primary-PG:1.5KVac; 10mA. Secondary-PG:0.5KVac;10mA.

Isolation Resistance

100M ohms

EMI Conduction&Radiation

Compliance to EN55022(CISPR22)ClassB

Harmonic Current

Compliance to EN61000-3-2,17625.1-2003

EMS Immunity

Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA

OTHERS

MTBF (MIL-HDBK-217F)

More than 100,000Hrs (25℃, Full load)

Dimension  (L*W*H)

226.5×115×50mm

Packing

10PCS/CTN, GW:11.6kgs

Cooling method

Fored air cooling(Built-in fan)

NOTE

1.      All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.

2.      Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.

3.  The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.