other
Search
Home Search
  • PD-H35SX power supply
    PD-H35SX
    Ø  No Load power consumption<0.5W Ø  High AC input Ø  Miniature size,high power density,high efficiency,long life and high reliability Ø  Withstand 300VA surge input for 5 sec. Ø  Output protections: OLP/OVP/SCP/OPP Ø  Wide operating ambient temp (-25℃~70℃),100% @50℃、70%@70℃ Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Suitable for critical applications Ø  3 years warranty     SPECIFICATION                                              MODEL PD-H35S12 OUTPUT DC Output   Rated Current 2.6A Current Range      0~2.6A Ripple and Noise  Note 2 -25~70℃   Voltage ADJ.  Range 11.4~12.6V Voltage Accuracy ±2.0% Line Regulation ±1.0% Load Regulation ±2.0% Set-up Time <1.0S (230Vac input, Full load) Hold up Time >20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range     Frequency Range 47Hz~63Hz Efficiency ( Typical) 82% AC Current (max.) 0.7A 2.5A Inrush Current (Typical) <40A@230Vac      Cold start Leakage Current Input—output:<3.5mA     Input—PG:<0.25mA PROTECTION Over Load   Over power 37.8~54W, constant power Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum.   Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards   Withstand Voltage Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022 ClassB; FCC PART15 B EMS Immunity Compliance to EN61000-4-2,4,5,8,11; OTHERS MTBF (MIL-HDBK-217F)   Dimension  (L*W*H) 94.5×51.5×29.5mm Packing 48PCS/CTN, 10.42KGS, 0.03CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. 4. Powerld offer accessories for Din-35 rail bar. Please contact sales staff for details. We are professional manufacturer engaged in the research, development, production, sale and service of Industrial power supply,We sincerely look forward to cooperating with you and creating the future together!
  • PD-H60SX power supply
    PD-H60SX
    Ø  No Load power consumption<0.5W Ø  High AC input range Ø  Miniature size,high power density,high efficiency,long life and high reliability Ø  Withstand 300VA surge input for 5 sec. Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temp (-25℃~70℃),100% @50℃、70%@70℃ Ø  Operating altitude up to5000M Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Easy assembling from top side Ø  PCB soldering side with conformal coating Ø  Suitable for critical applications Ø  3 years warranty      SPECIFICATION                                              MODEL PD-H60S12 OUTPUT DC Output 12V Rated Current 5.0A CurrentRange     0~5.0A Ripple and Noise   (-25℃~70℃)Note 2 ≤120mVp-p Voltage ADJ. Range 11.4~13.2V Voltage Accuracy ±3% Line Regulation ±0.5% Load Regulation ±1% Set-up Time <1.5S (230Vac input, Full load) Hold up Time >50mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   176Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) ≥84% AC Current (max.) <1.3A Inrush Current (Typical) <40A@230Vac     Cold start Leakage Current Input—output:<3.5mA    Input—PG:<0.25mA PROTECTION Over Load 5.25~7.5A, constant power Over power 63~90W, constant power Over Voltage 13.8~18V, Constant Voltage Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022 / FCC PART15 ClassB EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 99×82×35mm Packing 40PCS/CTN, 12.8KGS, 0.043CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. 4. Powerld offer accessories for Din-35 rail bar. Please contact sales staff for details. We are professional industrial power supply manufacturer,can offer kinds of industrial power supply and custom service.call us now!
  • PD-H75SX power supply
    PD-H75SX
    Ø  No Load power consumption<0.5W Ø  High AC input Ø  Miniature size,high power density,high efficiency,long life and high reliability Ø  Withstand 300VA surge input for 5 sec. Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temp (-25℃~70℃),100% @50℃、70%@70℃ Ø  Operating altitude up to5000M Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Easy assembling from top side Ø  PCB soldering side with conformal coating Ø  Suitable for critical applications Ø  3 years warranty      SPECIFICATION                                              MODEL PD-H75S24 OUTPUT DC Output 24V Rated Current 3A CurrentRange     0~3A Ripple and Noise note2 0℃~70℃ ≤200mV -25℃~0℃ ≤400mV Voltage ADJ. Range 22.8~26V Voltage Accuracy ±3.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <1.5S (230Vac input, Full load) Hold up Time >50mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   176Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 87% AC Current (max.) <1.3A Inrush Current (Typical) <40A@230Vac     Cold start Leakage Current Input—output:<3.5mA    Input—PG:<0.25mA PROTECTION Over Load 3.15~4.5A, constant power Over power 75.6~108W, constant power Over Voltage 27.6~36V, Constant Voltage Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022 / FCC PART15 ClassB EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 99×82×35mm Packing 40PCS/CTN, 12.8KGS, 0.043CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. 4. Powerld offer accessories for Din-35 rail bar. Please contact sales staff for details. We are professional industrial power supply manufacturer,can offer kinds of industrial power supply and custom service.call us now!
    A total of

    1

    pages
#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #