other
Search
Home Search
  • PD-50-X Power Supply
    PD-50-X
    Ø  No Load power consumption<0.5W Ø  Universal AC input range (88~264Vac) Ø  Miniature size, high power density, high efficiency, long life and high reliability Ø  Withstand 300VA surge input for 5 sec. Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temp (-25℃~70℃) Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Easy assembling from top side Ø  PCB soldering side with conformal coating Ø  Suitable for critical applications Ø  3 years warranty      MODEL PD-50-5 PD-50-12 PD-50-15 PD-50-24 PD-50-48 OUTPUT DC Output 5V 12V 15V 24V 48V Rated Current 8A 4.2A 3.4A 2.2A 1.12A Current Range      0~8A 0~4.2A 0~3.4A 0~2.2A 0~1.12A Ripple and Noise   Note 2 0~70℃ <80mV <120mV <120mV <200mV <200 mV -25-0℃ <80mV <200mV <200mV <300mV <500mV Voltage ADJ.  Range 4.75~5.5V 11.4~13.2V 14.25~15V 22.8~26.4V 45.6~52.8V Voltage Accuracy ±3.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <1.5S (230Vac input, Full load) Hold up Time >50mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   88Vac~264Vac,127~370Vdc Frequency Range 47Hz~63Hz Efficiency ( Typical) 115Vacinput 79% 82.5% 83.5% 85% 86.5% 230Vacinput 80% 84.5% 85.5% 87% 88.5% AC Current (max.) <1.3A Inrush Current (Typical) <45A@230Vac      Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA    (input 264Vac, 63Hz) PROTECTION Over Load  8.4~12A 4.41~6.3A 3.57~5.1A 2.31~3.3A 1.155~1.65A Protection type: 5V is hiccup mode, rest are constant power, auto recovery Over Voltage 5.75~7.5V 13.8~18V 17.25~22.5V 27.6~36V 55.2~72V Protection type: constant voltage, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards UL62368-1 ; IEC62368-1; EN62368-1 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 100M ohms EMC Emission Compliance to EN55032 Class B EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 99×82×35mm Packing 40PCS/CTN, 12.8KGS, 0.043CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • PD-50-X-D power supply
    PD-50-X-D
    Ø  No Load power consumption<0.5W Ø  Universal AC input range Ø  Miniature size,high power density,high efficiency,long life and high reliability Ø  Withstand 300VA surge input for 5 sec. Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temp (-25℃~70℃),100% @50℃、70%@70℃ Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Easy assembling from top side Ø  PCB soldering side with conformal coating Ø  Suitable for critical applications Ø  3 years warranty      MODEL PD-50-5-D PD-50-12-D PD-50-24-DII OUTPUT DC Output 5V 12V 24V Rated Current 8A 4.2A 2.2A Current Range      0~8A 0~4.2A 0~2.2A Ripple and Noise    (-25℃~70℃) Note 2 <80mV <120mV <200mV Voltage ADJ.  Range 4.75~5.5V 11.4~13.2V 22.8V-26.4V Voltage Accuracy ±3.0% ±3.0% ±3.0% Line Regulation ±0.5% ±0.5% ±0.5% Load Regulation ±1.0% ±1.0% ±1.0% Set-up Time <1.5S (230Vac input, Full load) Hold up Time >50mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   90Vac~264Vac,127~370Vdc Frequency Range 47Hz~63Hz Efficiency ( Typical) 80% 84.5% 87% AC Current (max.) <1.3A Inrush Current (Typical) <40A@230Vac      Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Load 105%~150% of rated output current, constant power Over power 105%~150% of rated output current, constant power Over Voltage 115%~150% of rated output voltage, Constant Voltage Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards UL62368-1; IEC62368-1; EN62368-1 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance ≥100M ohms EMC Emission Compliance to EN55032 Class B EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 99×82×35mm Packing 40PCS/CTN, 12.8KGS, 0.043CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
    A total of

    1

    pages
#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #