DG-U75SX
Ø Universal AC input range(90~264Vac) Ø Long life, high reliability and high efficiency Ø Built-in current limiting circuit Ø Output protections: OVP/OLP/SCP/OTP Ø Wide operating ambient temp (-20℃~70℃) Ø Can be installed on TS-35/7.5 or TS-35/15 Ø 100% full load burn-in test Ø Suitable for critical applications Ø Ultra-slim,45mm width Ø 3 years warranty SPECIFICATION MODEL DG-U75S12 DG-U75S24 OUTPUT DC Output 12V 24V Rated Current 6.25A 3.2A CurrentRange Note 1 0~6.25A 0~3.2A Ripple and Noise Note 2 0~70℃ ≤120mV ≤120mV -20℃ ≤240mV ≤240mV Voltage ADJ. Range 12~14V 24~28V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <1.5S@230Vac ; <3.0mS@115Vac Hold up Time ≥10mS@115Vac; ≥20mS@230Vac Full load Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange 90Vac~264Vac, 127Vdc-370Vdc FrequencyRange 47Hz~63Hz Efficiency ( Typical) 82% 87% AC Current (max.) <2.0A/115VAC ; <1.0A/230VAC Inrush Current (Typical) 20A/115Vac ; 35A/230Vac Cold start Leakage Current Input—output:<0.25mA Input—PG:<3.5mA (264Vac input, 63Hz) PROTECTION Over Load 7.0~9.5A 5.25~6.5A Protection type: Constant current Over voltage 15~18V 29~33V Protection type: Shut down, re-power on. Over temperature 100±5℃, detect on heat sink of power transistor; shut down O/P, re-power on. Short Circuit Long-term mode, auto recovery Operating amb. Temp. & Hum. -20℃~70℃; 20%~90%RH No condensing (pls refer to derating curve) ENVIRONMENT Storage Temp. & Hum. -40℃~85℃; 5%~95%RH No condensing Safety Standards UL508, UL60950, EN60950 SAFETY &EMC Note 3 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG: 2.0KVac/10mA. Secondary-PG: 0.5KVac/10mA. Isolation Resistance 10Mohms EMC Emission Compliance to EN55022, EN55024, FCC PART 15 Class B Harmonic Current Compliance to EN61000-3-2, CLASS A EMC Immunity Compliance to EN61000-4-2,3,4,5,6,11; heavy industry level MTBF (MIL-HDBK-217F) More than 500,000Hrs (25℃, Full load) OTHERS Dimension (L*W*H) 124*119*45mm Packing 24pcs/CTN,15.0Kg, 0.04cbm Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com. We have a complete DIN rail power supply product catalog, providing reliable quality DIN rail power supply and affordable prices, fast delivery, customizable, please leave a message for consultation.