other
Search
Home Search
  • PD-20-X power supply
    PD-20-X
    Ø  Universal AC input/ Full range Ø  High Efficiency, and High reliability Ø  Ultra-miniature size, low profile Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temperature (-25℃~70℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  3 years warranty MODEL PD-20-3.3 PD-20-5 PD-20-12 PD-20-15 PD-20-24 PD-20-48 OUTPUT DC Output 3.3V 5V 12V 15V 24V 48V Rated Current 4A 4A 1.67A 1.34A 0.84A 0.42A Current Range     Note 1 0~4A 0~4A 0~1.67A 0~1.34A 0~0.84A 0~0.42A Ripple and Noise  Note 2 0~60℃ <50mV <50mV <50mV <50mV <50mV <100mV -20~0℃ <75mV <75mV <75mV <75mV <75mV <100mV Voltage ADJ.  Range 3.1~3.6V 4.4~5.6V 11.1~13.1V 13.7~16.1V 22.0~25.4V 45.6~50.4V Voltage Accuracy ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% Load Regulation ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% Set-up Time <2.0S (115Vac input, Full load); <1.0S (230Vac input, Full load) Hold up Time >10mS(115Vac input, Full load); >20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   85Vac~264Vac,120Vdc~370Vdc Frequency Range 47Hz~63Hz Efficiency ( Typical) 115Vacinput 69% 76% 79% 80% 80% 80% 230Vacinput 68% 75% 78% 79% 79% 79% AC Current (max.) 0.4A 0.5 0.5A 0.5A 0.5A 0.5A Inrush Current (Typical) Cold start  20A@115Vac    40A@230Vac      Leakage Current Input—output:<0.35mA     Input—PG:<0.75mA PROTECTION Over Load 105%~150% rated output power; Hiccup mode, auto recovery Over Voltage 110%~140% of rated output voltage, Constant Voltage.  Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃;  20%~90%RH  No condensing(refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY & EMC Note 3 Safety Standards UL60950-1; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVa;≤10mA .Primary-PG:1.5KVac;≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100Mohms EMI Conduction&Radiation Compliance to EN55022(CISPR22)ClassB Harmonic Current Compliance to EN61000-3-2,17625.1-2003 EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 89×51×20mm Packing 60PCS/CTN, 7.6KGS, 0.017CBM Cooling method Cooling by free air convection NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.        The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. We are Industrial power supply manufacturer with competitive price and good quality,which are widely recognized and trusted by users and can meet social needs.
  • PD-H75SX power supply
    PD-H75SX
    Ø  No Load power consumption<0.5W Ø  High AC input Ø  Miniature size,high power density,high efficiency,long life and high reliability Ø  Withstand 300VA surge input for 5 sec. Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temp (-25℃~70℃),100% @50℃、70%@70℃ Ø  Operating altitude up to5000M Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Easy assembling from top side Ø  PCB soldering side with conformal coating Ø  Suitable for critical applications Ø  3 years warranty      SPECIFICATION                                              MODEL PD-H75S24 OUTPUT DC Output 24V Rated Current 3A CurrentRange     0~3A Ripple and Noise note2 0℃~70℃ ≤200mV -25℃~0℃ ≤400mV Voltage ADJ. Range 22.8~26V Voltage Accuracy ±3.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <1.5S (230Vac input, Full load) Hold up Time >50mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   176Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 87% AC Current (max.) <1.3A Inrush Current (Typical) <40A@230Vac     Cold start Leakage Current Input—output:<3.5mA    Input—PG:<0.25mA PROTECTION Over Load 3.15~4.5A, constant power Over power 75.6~108W, constant power Over Voltage 27.6~36V, Constant Voltage Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022 / FCC PART15 ClassB EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 99×82×35mm Packing 40PCS/CTN, 12.8KGS, 0.043CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. 4. Powerld offer accessories for Din-35 rail bar. Please contact sales staff for details. We are professional industrial power supply manufacturer,can offer kinds of industrial power supply and custom service.call us now!
  • DG-30-SX power supply
    DG-30-SX
    Ø  Universal AC input range(90~264Vac) Ø  High efficiency, long life and high reliability Ø  Output protections: OVP/OLP/SCP Ø  Wide operating ambient temp (-25℃~70℃) Ø  Can be installed on TS-35/7.5 or 35/15 Ø  100% full load burn-in test Ø  PCB with conformal coating Ø  Suitable for critical applications Ø  Cooling by free air convection Ø  3 years warranty SPECIFICATION MODEL DG-30-S12 DG-30-S24 OUTPUT DC Output 12V 24V Rated Current 2.5A 1.25A CurrentRange    Note 1 0~2.5A 0~1.25A Ripple and Noise  Note 2 10~50℃ ≤50mV ≤70mV -25~10℃ ≤100mV ≤140mV Voltage ADJ. Range 12~14V 24~28V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1% Set-up Time <1.5S @230Vac Full load Hold up Time ≥20mS @230Vac Full load Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac, 127VDC-370VDC(input V+ connect L, input V- connect N) FrequencyRange 47Hz~63Hz Efficiency ( Typical) 82% @230Vac input, full load 85% @230Vac input, full load AC Current (max.) <0.8A Inrush Current (Typical) 50A/230Vac  Cold start Leakage Current Input—output:≤0.25mA  Input—PE: ≤3.5mA  (264Vac input, 63Hz) PROTECTION Over Load 3~4.0A, hiccup mode, auto recovery 1.5~2.5A, hiccup mode, auto recovery Over voltage 15.0~16.8V, Constant voltage, auto recovery 28.8~31.2V, Constant voltage, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 5%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards UL60950, EN60950 Withstand Voltage Primary-Secondary: 3KVac/10mA; Primary-PE: 1.5KVac/10mA; Secondary-PE: 0.5KVac/10mA Isolation Resistance >10Mohms EMC Emission Compliance to EN55022, EN55024 Class B Harmonic Current Compliance to EN61000-3-2,CLASS A EMC Immunity Compliance to EN61000-4-2,3,4,5,6,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) 590,000Hrs (25℃, Full load) Dimension (L*W*H) 103.7*32*97.5mm Packing 36pcs/CTN, 8Kgs/CTN, 0.04cbm Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttps://www.powerld.com. DIN rail power supply is a kind of switching power supply, which can convert unstable input voltage into stable output voltage. We can meet all industry standards of DIN rail power supply. Learn more, follow us, and leave us a message.
  • PSF-200-X power supply
    PSF-200-X
    Ø  Universal AC input/ Full range Ø  Built-in Active PFC function Ø  Withstand 300Vac surge input for 5 sec. Ø  High efficiency up to 90%(typ) Ø  Output protections: OLP/OVP/SCP/OPP Ø  Wide operating ambient temperature (-20℃~70℃) Ø  All using105℃long life electrolytic capacitors. Ø  Free air convection for 150W and 200W with 20.5CFM forced air Ø  100% full load burn-in test Ø 5’’*3’’ compact size Ø  3 years warranty MODEL PSF-200-12 GZM-H25S12II PSF-200-24 PSF-200-27 PSF-200-48 OUTPUT DC Output 12V 8.5V 12V 12V 24V 27V 48V Rated Current 16.6A 3A 10.5A 2 A 8.4A 7.4A 4.167A CurrentRange(convection)    0~12.5A 0~3A 0~10.5A 0~2A 0~6.25A 0~5.5A 0~3.13A CurrentRange(20.5CFM fan) 0~16.6A 0~8.4A 0~7.4A 0~4.167A Ripple and Noise Note 20<Ta≤70℃ 0<Ta≤70℃ 120mVp-p 85mV 100mV 120mV 200 mVp-p 100 mVp-p 120 mVp-p -20≤Ta≤0℃ 200 mVp-p 200 mVp-p 150 mVp-p 240 mVp-p Voltage ADJ. Range ±10% of rated output voltage Voltage Accuracy ±1.0% ±3.0% ±5.0% ±2.0% ±2.0% Line Regulation ±0.5% ±0.5% ±1.0% ±0.5% ±0.5% Load Regulation ±1.0% ±2.0% ±1.0% ±2.0% ±2.0% Set-up Time ≤2S (230VAC input, Full load)& ≤4S (115VAC input, Full load) Hold up Time ≥16mS/150W 10mS/200W(115 / 230VAC IN AT FULL LOAD) Temperature Coefficient ±0.03%/℃ Overshootand Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac,127Vdc~370Vdc FrequencyRange 47Hz--63Hz Power Factor(Typical) PF>0.98/115VAC   PF>0.95/230VAC Efficiency ( Typical) ≥89% ≥89% ≥89% ≥90% AC Current (max.) <3A 2.5A 1.5A 0.3A 1.5A 1.5A 1.5A 1.5A Inrush Current (Typical) <50A@230Vac  <30A@115Vac  Cold start Leakage Current ≤3.5mA PROTECTION Over Current 105%~150% of rated output current, hiccup mode, auto recovery Over Power 105%~150% of rated output current, hiccup mode, auto recovery Over Voltage 125%~150% of rated output voltage, hiccup mode, auto recovery Short Circuit Long-term, Auto recovery ENVIRONMENT OperatingambTemp& Hum -20℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   Note 3 Safety Standards UL60950-1; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA .Secondary-PG:0.5KVDC;≤10mA . Isolation Resistance 100M ohms EMI Conduction&Radiation Compliance to EN55022,EN55024 ClassB Harmonic Current Compliance to EN61000-3-2,-3 EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11;EN55024,EN61000-6-2heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 128×76.5×34.6mm(5’’*3’’) Packing 21PCS/CTN, 8.46KGS, 0.015CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. We focus on your industrial power supply project needs, Offering reliable quality and high cost-effective products is always our top priority. Effective Communication within 24 hours.
  • PWF-100L-X Power Supply
    PWF-100L-X
    Ø  Universal AC input range (85~264Vac) Ø  Built-in Active PFC function, PF>0.93 Ø  Miniature size, high power density ,high efficiency, long life and high reliability Ø  Output protections: OLP/SCP/OPP Ø  Wide operating ambient temp (-20℃~65℃) Ø  Operating altitude up to5000M Ø  100% full load burn-in test Ø  Easy assembling from top side Ø  PCB soldering side with conformal coating Ø  Suitable for critical applications Ø  3 years warranty       SPECIFICATION                                              MODEL PWF-100L-12 PWF-100L-24 PWF-100L-36 PWF-100L-48 OUTPUT DC Output 12V 24V 36V 48V Rated Current 8.5A 4.2A 2.75A 2.15A CurrentRange    Note 1 0~8.5A 0~4.2A 0~2.75A 0~2.15A Ripple and Noise  Note 2 0~65℃ ≤100mV ≤150mV ≤250mV ≤250mV -20~0℃ ≤200mV ≤300mV ≤500mV ≤500mV Voltage ADJ. Range ±10% of rated output voltage Voltage Accuracy ±2.0% ±1.0% ±1.0% ±1.0% Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% Load Regulation ±0.5% ±0.5% ±1.0% ±0.5% Set-up Time ≤2S   (230Vac input, full load) Hold up Time ≥20mS (230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   85Vac~264Vac FrequencyRange 47Hz~63Hz Power factor (typical) PF>0.93@230Vac Efficiency (Typical)230Vac input ≥85% ≥86% ≥86% ≥87% Efficiency (Typical)120Vac input ≥83% ≥83% ≥83% ≥84% AC Current (max.) 1.7A/115Vac 0.8A/230Vac Inrush Current (Typical) <50A@230Vac     Cold start Leakage Current Input—output: ≤0.25mA   Input—PG: ≤3.5mA PROTECTION Over Load 105%~200% of rated output current, hiccup mode, auto recovery Over power 105%~200% of rated output current, hiccup mode, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -20℃~65℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -20℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1 2ndEd; IEC 60950-1:2005(2ndEd) ;EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance 100Mohms EMSEmission Compliance to EN55022, EN55024, FCC PART 15 CLASS B Harmonic Current Compliance to EN61000-3-2, Class D EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 199×99×38mm Packing 20PCS/CTN, 14.5KGS, 0.04CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com Powerld enterprises is specialized in switching power supply since 1991, obtained ISO9001 certificate in 2002, ISO14001 certificate in 2006.As a professional switching power supply manufacturer,Powerld can supply a broad range of power supply,we can not only supply our customers with high quality products,but also our best service and fast delivery time.
  • GST-H150SX-M power supply
    GST-H150SX-M
    Ø  High Efficiency, and High reliability Ø  Output protections: OCP/OPP/SCP Ø  Wide operating ambient temperature (-10℃~50℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  1 years warranty SPECIFICATION MODEL GST-H150S8.5-M GST-H150S12-M GST-H150S24-M GST-H150S28-M GST-H150S36-M GST-H150S48-M OUTPUT DC Output 8.5V 12V 24V 28V 36V 48V Rated Current 17.5A 12.5A 6.0A 5.5A 4A 3.0A CurrentRange    0~17.5A 0~12.5A 0~6.0A 0~5.5A 0~4.0A 0~3.0A Ripple and Noise  Note 2 100Mv 120mV 200mV 200mV 200 mV 200mV Voltage ADJ. Range ±5% of rated output voltage Voltage Accuracy ±2.0 Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <=1.0S (220Vac input, Full load) Hold up Time >=20mS(220Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange  176Vac~265Vac FrequencyRange 47Hz~63Hz Efficiency (Typical) 220Vac 76% 80% 81% 82% 85% 85% AC Current (max.) 4.0A 2.0A 1.9A 2A 2.0A 1.8A 0.50A Inrush Current (Typical) 40A@220Vac  Cold start Leakage Current <3.5mA PROTECTION Over Current 105%~150% of rated output current, auto recovery Over Power 105%~150% of rated output current, auto recovery Shorted Circuit Long-term mode,auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -10℃~50℃; 20%~90%RH No condensing Storage Temp. & Hum. -25℃~85℃; 10%~95%RH No condensing SAFETY &EMC   Safety Standards EN60950-1 Withstand Voltage Primary-Secondary:1.5KVac; Primary-PG:1.5KVac; Secondary-PG:0.5KVDC Isolation Resistance 100M ohms OTHERS MTBF (MIL-HDBK-217F) More than 100,000Hrs (25℃, Full load) Dimension (L*W*H) 199×98×40mm Connection 7P/8.025mm barrier terminal block Cooling method Cooling by free air convection NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. Powerld enterprises is specialized in switching power supply since 1991, obtained ISO9001 certificate in 2002, ISO14001 certificate in 2006.As a professional switching power supply manufacturer,Powerld can supply a broad range of power supply,we can not only supply our customers with high quality products,but also our best service and fast delivery time.
  • VAT260UPXAA
    VAT260UPXAA
    Ø  Universal AC input (90~264Vac) Ø  With Active PFC, PF>0.95 Ø  Stand-by power consumption: 0.35W Ø  High Efficiency, long life and High reliability Ø  Output protections: OCP/OVP/SCP/OTP Ø  Wide operating ambient temperature (-30℃~65℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Fanless, quiet working Ø  PCB with conformal coating Ø  Low profile, 23mm Ø  3 years warranty    Ø  UL/CE/CCC/CB approved MODEL VAT260UP4.2AA VAT260UP5AA OUTPUT DC Output 4.2V 5V Rated Current 50A 50A CurrentRange    Note 1 0~50A 0~50A Ripple and Noise  Note 2 0~65℃ ≤250mV ≤300mV -30~0℃ ≤500mV ≤600mV Voltage Accuracy ±3% Set-up Time @25℃ ≤4S (220Vac input, 50A) Temperature Coefficient ±0.03%/℃ Overshoot ≤5.0% INPUT Voltage Range 90Vac~264Vac Rated input voltage range 100~240Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 90% @220Vac input, 50A ( 91% @220Vac, 60% load) AC Current (max.) <3.5A Inrush Current (Typical) <80A@220Vac     Cold start Power Factor @25℃ >0.95 (input 220Vac, 50A) Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA  (input 264Vac, 63Hz) Input Protection Under voltage protection point 55Vac~85Vac, shut down Under voltage recovery point 60Vac-90Vac, auto recovery, return difference≥5V Output PROTECTION Over Current ≥55A , auto recovery Over Voltage 4.6~6.5V, auto recovery 5.5~7V, auto recovery Over Temperature Test at40A Ambient temp. Protection when ambient temp. is over 65℃; auto recovery when ambient temp. is lower than 50℃ Housing temp. Protection when temp. of upper housing is over 85℃; auto recovery when it is less than 70℃ Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -30℃~65℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 4) Safety Standards IEC 62368-1, UL62368-1, EN62368-1 approved Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVdc/10mA. Isolation Resistance 10Mohms EMI Conduction & Radiation Compliance to EN55032  Class A EMSImmunity Compliance toEN61000-4-2,4,5,11; OTHERS MTBF >100000Hrs (25℃, Full load),MIL-217 Method 2 Components Stress Method Dimension (L*W*H) 165*55*23mm Packing 24pcs/CTN, 9.2Kgs/CTN Cooling method Power supply fixed on the aluminum plate of 450*450*3mm. NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttp://www.powerld.com.cn.
  • VAT-UP200S-X-P
    VAT-UP200S-X-P
    Ø  Universal AC input (90~264Vac) Ø  With Active PFC, PF>0.95 Ø  Surge 300Vac for 60S Ø  High Efficiency, long life and High reliability Ø  Output protections: OLP/OVP/SCP/OTP/OPP Ø  1+1 parallel function, current sharing Ø  Wide operating ambient temperature (-40℃~65℃) Ø  Operating altitude up to5000m Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Fanless, quiet working Ø  PCB with conformal coating        Ø  3 years warranty MODEL VAT-UP200S-4.6-P VAT-UP200S-5-P OUTPUT DC Output 4.6V 5V Rated Current 40A 40A CurrentRange    Note 1 0~40A 0~40A Peak load 50A(50mS, 220Vac input) 48A(50mS, 220Vac input) Ripple and Noise  Note 2 0~65℃ ≤150mV ≤150mV Voltage Accuracy@-20~65C ±3% ±3% Line Regulation/ ±0.5% Load Regulation ±2% Set-up Time @25℃ ≤2S (220Vac input,40A) Hold up Time ≥5mS (220Vac input,32A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% Parallel (current sharing) Current-unbalance< 10% (single PS drive40Aload, the voltage of current share bus is 5~6V) INPUT VoltageRange  Note 3 90Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 110Vac 87% 89% 220Vac 88% 90% AC Current (max.) <3.5A Inrush Current (Typical) <15A@220Vac     Cold start Power Factor @25℃ >0.95 (input 220Vac,40A) Stand by power consumption <4W (input 220Vac) Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA  (input 264Vac, 63Hz) PROTECTION Over Load 44~65A, hiccup mode, auto recovery 45~55A, hiccup mode, auto recovery Over Power 193~299W, hiccup mode, auto recovery 225~275W, hiccup mode, auto recovery Over Voltage 5.1~7V, hiccup mode, auto recovery 5.2~6.5V, hiccup mode, auto recovery Over Temperature 105℃+10℃(detect on temperature controller of PFC);shut down, auto recovery after the temperature goes down to75℃ Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~65℃; 20%~90%RH No condensing(refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 4) Safety Standards UL60950-1 2ndEd; IEC 60950-1:2005(2ndEd) ;EN60950-1:2006 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 10Mohms EMI Conduction&Radiation Compliance to EN55022, EN55024, FCC PART 15 CLASS B Harmonic current Compliance toEN61000-3-2CLASSD EMSImmunity Compliance toEN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) >200000h (25℃, Full load) Dimension (L*W*H) 210*50*29mm Packing 28PCS/CTN, 0.04CBM Power Good Signal Working properly: 3.3V Working abnormally: <0.7V Reverse voltage start 4.6V output When output reverse voltage is 5~5.1V, PS starts normally. 5V output When output reverse voltage is 5~10V, PS starts normally. Cooling method Cooling by free air convection NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and 25℃of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttp://www.powerld.com.cn.
    A total of

    2

    pages
#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #