  • CMG-H150D5G+12-M
    CMG-H150D5G+12-M
    Features: Ø  High AC voltage input (176~264Vac) Ø  High Efficiency, and High reliability Ø  Output protections: SCP/OVP/OPP/OLP Ø  Wide operating ambient temperature (-25℃~65℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  2 years warranty              Ø  Isolated Dual Outputs MODEL CMG-H150D5G+12-M OUTPUT DC Output V1 V2 5V 12V Rated Current 10A 8A 1~10A 0.8~8A Ripple and Noise Note2 0~65℃ ≤50mV ≤120mV -25℃ ≤100mV ≤240mV Voltage ADJ.  Range 4.6~5.4V / Voltage Accuracy ±1.0% ±10.0% Line Regulation ±0.5% ±1.0% Load Regulation ±3.0% ±10.0% Set-up Time <1.5S (220Vac input, Full load) Hold up Time >20mS(220Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   176Vac~264Vac Frequency Range 47Hz--63Hz Efficiency ( Typical) 75% AC Current (max.) <1.9A Inrush Current (Typical) <50A@220Vac      Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Power 175~225W, Hiccup mode, auto recovery Over Current V1: 11~22A, hiccup mode, auto recovery Over Voltage V1: 5.25~7.5V, Hiccup mode, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~65℃;  20%~90%RH  No condensing Storage Temp. & Hum. -30℃~85℃;  10%~95%RH  No condensing SAFETY &EMC   (Note 5) Safety Standards GB4943/EN60950 Withstand Voltage Primary-Secondary: 3.0KVac/10mA ; Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA.  Output V1—V2: 0.5KVDC/10mA. Test time:1 min Isolation Resistance 10M ohms EMI Conduction&Radiation Compliance to EN55022 Class B Harmonic Current Compliance to EN61000-3-2, Class A EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 199×99×38mm Packing 20PCS/CTN, 15KGS, 0.04CBM Cooling method Cooling by free air convection NOTE   1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.  The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • GS-25-12II
    GS-25-12II
    Ø  Universal AC input range(90~264Vac) Ø  Miniature size, high power density, high efficiency, long life and high reliability Ø  Output protections: OLP/OPP/SCP Ø  Wide operating ambient temp (-10℃~45℃) Ø  Altitude up to5000m Ø  100% full load burn-in test Ø  1 year warranty     SPECIFICATION                                              MODEL GS-25-12II OUTPUT DC Output 12V Rated Current 2A Current Range      0~2A Ripple and Noise  Note 2 0~45℃ <100mV -10~0℃ <120mV Voltage ADJ.  Range 10.8~13.2V Voltage Accuracy ±3.0% Line Regulation ±0.25% Load Regulation ±3.0% Set-up Time ≤1.0S (220Vac input, Full load) Hold up Time >20mS(220Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   90Vac~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) 220Vac,full load ≥78% AC Current (max.) <0.8A 2.5A 0.7A 0.7A 0.7A Inrush Current (Typical) <50A@220Vac      Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Load 2.1~3A, hiccup mode, auto recovery Over power 25.2~36W, hiccup mode, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -10℃~45℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -25℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards GB4943/EN60950 Withstand Voltage Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance 100M ohms EMC Emission Compliance to EN55022 Class B EMC Immunity Compliance to EN61000-4-2,4,5,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 115×49×29mm Packing 72PCS/CTN, 16.0KGS, 0.04CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn. We always can deliver high-end quality industrial power supply to our customers on time.Welcome you to contact us for more power supply information and look forward to working with you!
  • GS-35-12 Power Supply
    GS-35-12
    Ø  Universal AC input range(90~264Vac) Ø  High efficiency, long life and high reliability Ø  Output protections: OLP/SCP/OPP Ø  Wide operating ambient temp (0℃~50℃) Ø  Altitude up to5000m Ø  100% full load burn-in test Ø  1 years warranty SPECIFICATION                                                           MODEL            GS-35-12             DC Output         12V         Rated Current          3A         Current Range     Note 1          0~3A         Ripple and Noise          Note 2          0~50℃         <120mV         Voltage ADJ.  Range         11.4V-12.6V         Voltage Accuracy         ±1.0%         Line Regulation           ±0.5%         Load Regulation         ±0.5%         Set-up Time         ≤1S (230Vac input, Full load) ; ≤2S (115Vac input, Full load)         Hold up Time         ≥20mS(230Vac input, Full load) ; ≥10mS(115Vac input, Full load)         Temperature Coefficient         ±0.03%/℃         Overshoot and Undershoot         <5.0%         INPUT         Voltage Range           90Vac~264Vac         Frequency Range         47Hz~63Hz         Efficiency ( Typical)     ≥82%         AC Current (max.)      <1 A         2.5A         Inrush Current (Typical)     ﹤45A@230Vac max   Cold start         Leakage Current         Input—output:<0.25mA     Input—PG:<3.5mA         PROTECTION         Over Load         3.3A~4.5A, Hiccup mode, auto recovery         Over power         110%~150% of rated power, hiccup mode, auto recovery         Shorted Circuit         Long-term mode, auto recovery         ENVIRONMENT         Operating amb. Temp. & Hum.         0℃~50℃;  20%~90%RH  No condensing         Storage Temp. & Hum. -       40℃~85℃;  10%~95%RH  No condensing         SAFETY &EMC   Note 3         Safety Standards         EN60950/UL60950         Withstand Voltage         Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-                            PG:0.5KVDC;≤10mA.         Isolation Resistance     ≥100M ohms         EMC Emission         Compliance to EN55022 Class B         EMC Immunity         Compliance to EN61000-4-2,3,4,5,6,8,11;         OTHERS         MTBF (MIL-HDBK-217F)         More than 200,000Hrs (25℃, Full load)         Dimension  (L*W*H)           98×81×35mm         Packing         45PCS/CTN, 17.2KGS, 0.04CBM         Cooling method         Cooling by free air convection          NOTE         1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature.         2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor.         3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn. We alwa...
  • GS-60-12Power Supply
    GS-60-12
    MODEL GS-60-12 ABS-75-12 ABS-75-24 ABS-75-48 OUTPUT DC Output 12V 12V 24V 48 Rated Current 5A 6A 3.2A 1.62A Current Range     Note 1 0~5A 0~6A 0~3.2A 0~1.62A Ripple and Noise  Note 2 0~50℃ <120mV Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±0.5% Set-up Time ≤1S /230Vac input, Full load) Hold up Time ≥20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   90Vac~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) ≥82% ≥84% ≥86.5% ≥88% AC Current (max.) <1.3 A 2.5A Inrush Current (Typical) ﹤45A@230Vac   Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Load 5.5~7.5A, hiccup mode, auto recovery Over power 110%~150% of rated power, hiccup mode, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. 0℃~50℃;  20%~90%RH  No condensing Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards EN60950 Withstand Voltage Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100M ohms EMC Emission / EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 99*82*35mm Packing 45PCS/CTN, 17.2KGS, 0.04CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. We always can deliver high-end quality industrial power supply to our customers on time.Welcome you to contact us for more power supply information and look forward to working with you!
  • GS-240-12Power Supply
    GS-240-12
    SPECIFICATION                                                MODEL GS-240-12 ABS-100-12 ABS-100-24 ABS-100-48 OUTPUT DC Output 12V 12V 24V 48 Rated Current 20A 8.5A 4.5A 2.3A Current Range     Note 1 0~20A 0~8.5A 0~4.5A 0~2.3A Ripple and Noise  Note 2 0~45℃ <120mV Voltage ADJ.  Range 10.8V-13.2V 10.8V-13.2V 21.6V-26.4V 43.2~52.8V Voltage Accuracy ±2.0% ±1.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2S /230Vac input, Full load) Hold up Time ≥10mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   180Vac~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) ≥85% ≥81% ≥85% ≥86% AC Current (max.) <3 A 2.5A Inrush Current (Typical) ﹤50A@220Vac   Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Load 21~30A, hiccup mode, auto recovery Over power 252~360W, hiccup mode, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -10℃~45℃;  20%~90%RH  No condensing Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards EN60950 Withstand Voltage Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100M ohms EMC Emission / Harmonic Current Compliance to EN61000-3-2, Class D EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 199×99×38mm Packing 20pcs/CNT, 13.6Kgs/CTN, 0.04cbm Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. We always can deliver high-end quality industrial power supply to our customers on time.Welcome you to contact us for more power supply information and look forward to working with you!
  • PDF-800-C12 Power Supply
    PDF-800-C12
    MODEL PDF-800-C12 OUTPUT DC Output 12V 5.0V 4812V 32V Rated Current (90~175Vac) 54A Rated Current (176~264Vac) 67A Ripple and Noise Note 2 0~50℃ ≤100mV -20~0℃ ≤100mV Voltage ADJ.  Range 11.4~12.6V Voltage Accuracy ±2% ±2.0% ±2.0% ±1.0% ±1.0% ±2.0% ±1.0% Line Regulation ±0.5% ±0.5% ±0.5% ±0.3% ±0.2% ±0.2% ±0.2% Load Regulation ±2% ±1.0% ±1.0% ±0.5% ±0.5% ±1.0% ±0.5% Set-up Time ≤8S (220Vac input, Full load) Hold up Time ≥5mS (220Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   90Vac~264Vac Frequency Range 47Hz--63Hz Power Factor(Typical) PF≥0.98/230VAC     PF≥0.99/115VAC     Full Load Efficiency ( Typical) 85% @230Vac,67A. AC Current (max.) ≤10 A Inrush Current (Typical) <30A@230Vac       Cold start Leakage Current Input—output: ≤0.25mA     Input—PG: ≤3.5mA PROTECTION Over Load 74~87A, Constant current, auto recovery Over power 900~980W, Constant current, auto recovery Over Voltage 14~16V, Constant voltage, auto recovery Over Temperature 105℃+5℃(detect on Mosfet temperature);shut down,auto recovery after the temperature goes down to85℃ Short Circuit Long-term mode, constant current, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -20℃~60℃;  20%~90%RH  No condensing  (refer to derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC    (Note 3) Safety Standards UL60950, EN60950 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVac/10mA. Isolation Resistance 10M ohms EMI Conduction&Radiation Compliance to EN55022 Class A Harmonic Current Compliance to EN61000-3-2,Class D EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) DC OK 4V-6V Dimension  (L*W*H) 226×116.5×41mm Packing 12PCS/CTN, 16.8KGS, 0.04CBM Cooling method Fored air cooling(Built-in fan,the fan speed is controlled by load and internal temp.) NOTE 1.      All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.      Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn. We always can deliver high-end quality industrial power supply to our customers on time.Welcome you to contact us for more power supply information and look forward to working with you!