  • VAT-UP200S-X-60L-AII power supply
    VAT-UP200S-X-60L-AII
    l  AC input: 90VAC ~ 264VAC l  Built-in Active PFC, PF>0.95 l  High efficiency, long life and high reliability l  Output protections: OLP/SCP l  No fan suitable for quiet environment l  Wide operating ambient temperature  (-40℃~65℃) l  100% full load burn-in test l  Conformal coating l  3 years warranty MODEL VAT-UP200S-5-60L-AII OUTPUT DC Output 5V Output Pre set voltage 4.95-5.05V (220Vac input, load 0A) Rated Current 40A  ( PSU bottom fixed on heat sink of square > 250*250*2mm aluminum plate) CurrentRange    Note 1 0~40A Ripple and Noise 25~65℃ ≤150mV 0~25C ≤200mV Voltage Adj. Range 4.15~5.10V Voltage Accuracy ±2.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤1.0S (220Vac input, Full load) & ≤2.5S (110VAC input, Full load) Hold up Time ≥10mS(220Vac input , 80% load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5% INPUT VoltageRange 90Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 89%(220Vac input ,full load) AC Current (max.) <2.5A Inrush Current (Typical) <80A@220Vac     Cold start Power factor PF>0.95/110VAC   &   PF>0.93/220VAC  (at full load) PROTECTION Over Power 225W~300W, Hiccup, auto recovery Over Current 45A~60A, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~65℃; 20%~90%RH No condensing  (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Leakage Current Input—output: ≤0.25mA    Input—PG: ≤3.5mA (264Vac input,) Isolation Resistance 10Mohms EMI Conduction & Radiation Compliance to EN55022, EN55024, FCC PART 15  CLASS B Harmonic Current Compliance to EN61000-3-2 CLASS D EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25C, full load) Dimension (L*W*H) 208*60*30mm Packing TBD Cooling method Free air convection NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 100uF parallel capacitor. 3. he SPS is considered a component which will be installed into final equipment. We cannot guarantee that the final equipment will meet EMC directives, Final product manufactures must be re-confirm that their product meets EMC directives. We provide high-quality LED power supplies for indoor and outdoor, and a variety of specifications and models of LED power supplies are optional, suitable for specific lighting applications in multiple fields.
  • VAT-UP300S-X-60L-A power supply
    VAT-UP300S-X-60L-A
    l   AC input: 90 ~ 264Vac l   Built-in active PFC function, PF>0.95 l  High efficiency, long life and high reliability l   Output protections: OCP/SCP /OTP l   Wide operating ambient temperature (-40℃~65℃) l   Operating altitude up to 3000m l   100% full load burn-in test l   Conformal coating l   No fan suitable for quiet environment l   3 years warranty MODEL VAT-UP300S-5-60L-A VAT-UP300S-4.6-60L-A OUTPUT DC Output 5V 4.6V Rated Current 60A 60A CurrentRange    Note 1 0~60A 0~60A Peak load 70A, last 50mS at 220Vac Ripple and Noise 25~65℃ ≤150mV 0~25℃ ≤200mV Voltage Adj. Range 3.3~5.10V Voltage Accuracy ±2.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2.0S (220Vac input, Full load) Hold up Time ≥5mS(220Vac ,80% load) Temperature Coefficient ±0.03%/℃ Overshoot <5% INPUT VoltageRange 90Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 90% 90% AC Current (max.) <5A Inrush Current (Typical) <60A@220Vac     Cold start Power factor >0.95(220Vac input ,full load) PROTECTION Over Power 325W~450W, Hiccup mode, auto recovery Over Current 65A~90A, Hiccup mode, auto recovery Shorted Circuit Long-term mode, auto recovery Over Temperature 115℃+5℃(detect on L4/C1);shut down, auto recovery after the temperature goes down ENVIRONMENT Operating amb. Temp. & Hum. -40℃~65℃; 20%~90%RH No condensing  (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Leakage Current Input—output: ≤0.25mA    Input—PG: ≤3.5mA (264Vac input, 63Hz) Isolation Resistance 10Mohms EMI Conduction&Radiation Compliance toEN55022, EN55024, FCC PART 15  Class B Harmonic Current Compliance toEN61000-3-2 Class D EMSImmunity Compliance toEN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs(25℃, Full load) Dimension (L*W*H) 208*60*30mm Packing 32pcs/CTN Cooling method Free air flow(PSU fixed to aluminum heat-sink of 400mm*400mm*2mm) NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 100uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. We cannot guarantee that the final equipment will meet EMC directives, Final product manufactures must be re-confirm that their product meets EMC directives. We provide high-quality LED power supplies for indoor and outdoor, and a variety of specifications and models of LED power supplies are optional, suitable for specific lighting applications in multiple fields.
    A total of

    1

    pages
#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #