PDF-800-C12
MODEL PDF-800-C12 OUTPUT DC Output 12V 5.0V 4812V 32V Rated Current (90~175Vac) 54A Rated Current (176~264Vac) 67A Ripple and Noise Note 2 0~50℃ ≤100mV -20~0℃ ≤100mV Voltage ADJ. Range 11.4~12.6V Voltage Accuracy ±2% ±2.0% ±2.0% ±1.0% ±1.0% ±2.0% ±1.0% Line Regulation ±0.5% ±0.5% ±0.5% ±0.3% ±0.2% ±0.2% ±0.2% Load Regulation ±2% ±1.0% ±1.0% ±0.5% ±0.5% ±1.0% ±0.5% Set-up Time ≤8S (220Vac input, Full load) Hold up Time ≥5mS (220Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range 90Vac~264Vac Frequency Range 47Hz--63Hz Power Factor(Typical) PF≥0.98/230VAC PF≥0.99/115VAC Full Load Efficiency ( Typical) 85% @230Vac,67A. AC Current (max.) ≤10 A Inrush Current (Typical) <30A@230Vac Cold start Leakage Current Input—output: ≤0.25mA Input—PG: ≤3.5mA PROTECTION Over Load 74~87A, Constant current, auto recovery Over power 900~980W, Constant current, auto recovery Over Voltage 14~16V, Constant voltage, auto recovery Over Temperature 105℃+5℃(detect on Mosfet temperature);shut down,auto recovery after the temperature goes down to85℃ Short Circuit Long-term mode, constant current, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -20℃~60℃; 20%~90%RH No condensing (refer to derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC (Note 3) Safety Standards UL60950, EN60950 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVac/10mA. Isolation Resistance 10M ohms EMI Conduction&Radiation Compliance to EN55022 Class A Harmonic Current Compliance to EN61000-3-2,Class D EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) DC OK 4V-6V Dimension (L*W*H) 226×116.5×41mm Packing 12PCS/CTN, 16.8KGS, 0.04CBM Cooling method Fored air cooling(Built-in fan,the fan speed is controlled by load and internal temp.) NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn. We always can deliver high-end quality industrial power supply to our customers on time.Welcome you to contact us for more power supply information and look forward to working with you!