other
Search
Home Search
  • VA-UP200-X-G
    VA-UP200-X-G
    l  AC input: 100 ~ 264Vac l  Built-in Active PFC, PF>0.95 l  Withstand input 300Vac for 60s l  High efficiency, long life and high reliability l  Output protections: OCP/SCP/OPP/OTP l  Wide operating ambient temperature  (-40℃~60℃) l  No fan suitable for quiet environment l  100% full load burn-in test l  PCB with conformal coating l 3 years warranty MODEL VAT-UP200-5-G OUTPUT DC Output 5V Rated Current 50A CurrentRange    Note 1 0~50A Ripple and Noise  Note 2 0~55℃ ≤150mV -40~0℃ ≤400mV Voltage Accuracy 4.9~5.2V Line Regulation 4.9~5.2V Load Regulation 4.9~5.2V Set-up Time ≤2.0S (220Vac input, Full load) Hold up Time ≥5mS(220Vac input, load32A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <±5% INPUT VoltageRange 100Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 88%(220Vac input ,load 50A)    AC Current (max.) <3.5A Inrush Current (Typical) <60A@220Vac     Cold start Power factor >0.95(220Vac input ,40A) Standby power <4W Leakage Current Input—output: ≤0.25mA    Input—PG: ≤3.5mA (264Vac input, 63Hz) PROTECTION Over Power 225~300W @ 100~170Vac input; 275~300W @ 180~264Vac, Hiccup, auto recovery  Over Current 45A-60A @100-170Vac; 55-70A @ 180-264Vac, Hiccup, auto recovery  Shorted Circuit Long-term mode, auto recovery Over Temperature 115℃+5℃(detect on PFC inductance);shut down, auto recovery after the temperature goes down ENVIRONMENT Operating amb. Temp. & Hum. -40℃~60℃; 20%~90%RH No condensing  (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 10Mohms EMI Conduction & Radiation Compliance toEN55022 Class B Harmonic Current Compliance toEN61000-3-2,CLASS D EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 145*60*30mm Packing 36pcs/CTN Cooling method Free air convection NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2.    Measured at 100MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 100uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
    A total of

    1

    pages
#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #