other
Search
Home Search
  • VAT-UP200U-X
    VAT-UP200U-X
    Ø  Universal AC input Ø  Built-in active PFC,PF>0.95 Ø  High efficiency, long life and high reliability Ø  Output protection: SCP/OLP/OVP/OPP Ø  Wide operating ambient temperature (-20~65℃) Ø  All using105℃long life electrolytic capacitor Ø  100% full load burn-in test Ø  3 years warranty MODEL VAT-UP200U-5 OUTPUT DC Output 5.0V Rated Current 40A CurrentRange    Note 1 0~40A Peak load 45A (50mS, 220Vac input) Ripple and Noise  Note 2 0~65℃ ≤250mV -20℃ ≤300mV Voltage ADJ. Range / Voltage Accuracy ±4.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2S (220VAC input, 40A) Hold up Time ≥5mS (220Vac input, 32A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac FrequencyRange 47Hz--63Hz Power Factor(Typical) PF>0.95/230VAC   full load Efficiency ( Typical) ≥89%(220VAC, 40A)    ≥87%(110VAC, 30A) AC Current (max.) <2A Inrush Current (Typical) <60A@230Vac Cold start Leakage Current Input—output:<0.25mA    Input—PG:<3.5Ma (264Vac, 63Hz) PROTECTION Over Load 44~65A, Hiccup mode, auto recovery Over power 220~320W, hiccup mode, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -20℃~65℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing Vibration 10 ~ 500Hz,2G10min./1cycle, period for 60min. each along X,Y, Z axes Withstand Voltage Primary-Secondary: 3.0KVac; ≤10mA .Primary-PG: 1.5KVac; ≤10mA. Secondary-PG: 0.5KVDC; ≤10mA. Isolation Resistance 10Mohms SAFETY&EMC (Note 3) EMI Conduction & Radiation Compliance to EN55022, EN55024, FCC PART 15  CLASS B Harmonic Current Compliance to EN61000-3-2, Class D EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 100,000Hrs (25℃, Full load) Dimension (L*W*H) 210×31.5×30mm Packing 49PCS/CTN, 15KGS, 0.04CBM Cooling method Cooling by air NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttp://www.powerld.com.cn.
    A total of

    1

    pages
#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #