other
Search
Home Search
  • LPD-350-X Power Supply
    LPD-350-X
    Ø  AC input selectable by switch (115Vac/230Vac) Ø  High efficiency, long life and high reliability Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temp (-25℃~70℃) Ø  Altitude up to 5000m Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  3 years warranty SPECIFICATION MODEL LPD-350-12 LPD-350-24 OUTPUT DC Output 12V 24V Rated Current 29.17A 14.58A Current Range     0~29.17A 0~14.58A Ripple and Noise  Note 2 0~70℃ ≤150mV ≤150mV -25℃ ≤300mV ≤300mV Voltage ADJ. Range 10.2~13.8V 21.6~28.8V Voltage Accuracy ±1.5% ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% ±0.5% Set-up Time ≤2.3S Full load Hold up Time ≥12mS/115Vac input, Full load; ≥16mS/230Vac input, Full load Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT VoltageRange   90Vac~132Vac/180Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency @230Vac input ≥85% ≥87% AC Current (max.) <6.8A/115Vac ; <3.4A/230Vac 2.5A Inrush Current ﹤60A@ 115Vac/230Vac  Cold start Leakage Current Input—output:<0.25mA    Input—PG:<2.0mA (Input 240Vac) PROTECTION Over Load 30.63~43.75A 15.31~21.88A Protection type: Hiccup mode, auto recovery Over Power 367.5~525W 367.5~525W Protection type: Hiccup mode, auto recovery Over voltage 13.8~16.2V 28.8~33.6V Protection type: Constant voltage, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards GB4943 / EN60950 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:2.0KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance 10M ohms EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 190*99*30mm Packing TBD Cooling method Cooling by forced air (Built-in DC fan) NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com
  • VAT-UP200U-X
    VAT-UP200U-X
    Ø  Universal AC input Ø  Built-in active PFC,PF>0.95 Ø  High efficiency, long life and high reliability Ø  Output protection: SCP/OLP/OVP/OPP Ø  Wide operating ambient temperature (-20~65℃) Ø  All using105℃long life electrolytic capacitor Ø  100% full load burn-in test Ø  3 years warranty MODEL VAT-UP200U-5 OUTPUT DC Output 5.0V Rated Current 40A CurrentRange    Note 1 0~40A Peak load 45A (50mS, 220Vac input) Ripple and Noise  Note 2 0~65℃ ≤250mV -20℃ ≤300mV Voltage ADJ. Range / Voltage Accuracy ±4.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2S (220VAC input, 40A) Hold up Time ≥5mS (220Vac input, 32A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac FrequencyRange 47Hz--63Hz Power Factor(Typical) PF>0.95/230VAC   full load Efficiency ( Typical) ≥89%(220VAC, 40A)    ≥87%(110VAC, 30A) AC Current (max.) <2A Inrush Current (Typical) <60A@230Vac Cold start Leakage Current Input—output:<0.25mA    Input—PG:<3.5Ma (264Vac, 63Hz) PROTECTION Over Load 44~65A, Hiccup mode, auto recovery Over power 220~320W, hiccup mode, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -20℃~65℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing Vibration 10 ~ 500Hz,2G10min./1cycle, period for 60min. each along X,Y, Z axes Withstand Voltage Primary-Secondary: 3.0KVac; ≤10mA .Primary-PG: 1.5KVac; ≤10mA. Secondary-PG: 0.5KVDC; ≤10mA. Isolation Resistance 10Mohms SAFETY&EMC (Note 3) EMI Conduction & Radiation Compliance to EN55022, EN55024, FCC PART 15  CLASS B Harmonic Current Compliance to EN61000-3-2, Class D EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 100,000Hrs (25℃, Full load) Dimension (L*W*H) 210×31.5×30mm Packing 49PCS/CTN, 15KGS, 0.04CBM Cooling method Cooling by air NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttp://www.powerld.com.cn.
  • VAT-HP260-X-C
    VAT-HP260-X-C
    Ø  High voltage input (176~264Vac) Ø  With Active PFC, PF>0.95 Ø  Surge 300Vac for 60S Ø  High Efficiency, long life and High reliability Ø  Output protections: OCP/SCP/OPP/OTP Ø  Wide operating ambient temperature (-40℃~50℃) Ø  Operating altitude up to5000m Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Fanless, quiet working Ø  PCB with conformal coating Ø  Low profile, 30mm        Ø  3 years warranty MODEL VAT-HP260-5.2-C OUTPUT DC Output 5.2V Rated Current 40A Current Range     Note 1 0~50A Peak load 55A Ripple and Noise  Note 2 0~50℃ ≤150mV -40~0℃ ≤400mV Voltage Accuracy@-40~50C ±3% Line Regulation ±0.5% Load Regulation ±2% Set-up Time @25℃ ≤2S (220Vac input,40A) Hold up Time ≥5mS (220Vac input,32A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <±5% INPUT Voltage Range   Note 3 176~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) 92%  (220Vac input,40A) AC Current (max.) <3.5A Inrush Current (Typical) <60A@220Vac      Cold start Power Factor @25℃ >0.95  (input 220Vac,40A) Stand by power consumption <4W Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA   (input 264Vac, 63Hz) PROTECTION Over Current 55~80A , hiccup mode, auto recovery Over Power 286~416W, hiccup mode, auto recovery Over Temperature 115℃+5℃(detect on temperature protector);shut down, auto recovery after ambient temperature goes down to 50℃(temperature protector goes down to 85℃+15℃) Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~50℃;  20%~90%RH  No condensing(refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC   (Note 3) Safety Standards GB4943 / EN60950 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 10M ohms EMI Conduction&Radiation Compliance to EN55022, EN55024, FCC PART 15   CLASS B Harmonic current Compliance to EN61000-3-2, Class D EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) >200000h (25℃, Full load) Dimension  (L*W*H) 133*55*30mm Packing 49PCS/CTN, 15KGS, 0.04CBM Cooling method Cooling by free air convection NOTE 1.   All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.   Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
    A total of

    1

    pages
#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #