other
Search
Home Search
  • LPD-50-X Power Supply
    LPD-50-S
    Ø  No Load power consumption≤0.3W Ø  Universal AC input range (90~264Vac) Ø  Withstand 300Vac surge input for 5 sec. Ø  High efficiency, long life and high reliability Ø  Efficiency up to 90% Ø  Output protections: OCP/OVP/OPP/SCP Ø  Wide operating ambient temp (-30℃~70℃) Ø  Operating altitude up to 5000m Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  3 years warranty      MODEL LPD-50-S5 LPD-50-S12 LPD-50-S15 LPD-50-S24 LPD-50-S36 LPD-50-S48 OUTPUT DC Output 5V 12V 15V 24V 36V 48V Rated Current 10A 4.2A 3.4A 2.2 1.45A 1.1A Current Range      0~10A 0~4.2A 0~3.4A 0~2.2A 0~1.45A 0~1.1A Rated Power 50W 50.4W 51W 52.8W 52.2W 52.8W Ripple and Noise   note2 0~70℃ 80mV 120mV 120mV 200mV 200mV 200mV -30~0℃ 120mV 300mV 360mV 360mV 360mV 500mV Voltage ADJ.  Range 4.5~5.5V 10.8~13.2V 13.5~16.5V 21.6~26.4V 32.4~39.6V 43.2~52.8V Voltage Accuracy ±3.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time ≤1S (230Vac input, Full load) Hold up Time ≥30mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT Voltage Range   90Vac~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) 83% 86% 85% 88% 89% 90% AC Current (max.) <1.0A @ 115Vac Inrush Current (Typical) 60A@230Vac      Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Current 11~18A 4.62~7.5A 3.74~6A 2.42~3.75A 1.6~2.5A 1.21~1.875A Protection type: hiccup mode, auto recovery Over power 55~90W 55.5~90W 56.1~90W 58~90W 57.4~90W 58~90W Protection type: hiccup mode, auto recovery Over Voltage 5.75~6.9V 13.8~16.2V 18.75~21.75V 28.8~33.6V 41.4~48.6V 55.2~64.8V Protection type: hiccup mode, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Amb. Temp. & Hum. -30℃~70℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards GB4943/IEC62368  EN60335-1, EN61558-1/-2-16,CCC GB4943 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance 100M ohms EMC Emission Compliance to EN55032 Class B(Note 3) EMC Immunity Compliance to EN61000-4-2, 3, 4, 5, 6, 11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 99*82*30mm Packing 36pcs/CTN Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. Power supply is installed on a baseplate of 360*360*1mm for EMC test.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • LPD-100-X Power Supply
    LPD-100-X
    Ø        Universal AC input: 90~ 264Vac Ø        Can bear 300Vac for 5s Ø        No load power consumption<0.5W Ø        High efficiency, long life and high reliability Ø        Output protections: OCP/OVP/SCP Ø        Wide operating ambient temperature (-30℃~70℃) Ø        Altitude up to 5000m Ø        All using 105℃ long life electrolytic capacitors. Ø        100% full load burn-in test Ø        1 U low profile Ø        3 years warranty MODEL LPD-100-5 LPD-100-12 LPD-100-15 LPD-100-24 LPD-100-36 LPD-100-48 OUTPUT DC Output 5V 12V 15V 24V 36V 48V Rated Current 18A 8.5A 7A 4.5A 3A 2.3A Current Range 0~18A 0~8.5A 0~7A 0~4.5A 0~3A 0~2.3A Rated Power 90W 102W 105W 108W 108W 110.4W Ripple and Noise (note1) 120 mV 150mV 150mV 200mV 200mV 200mV Voltage ADJ.  Range 4.5~5.5V 10.8~13.2V 13.5~16.5V 21.6~26.4V 32.4~39.6V 43.2~52.8V Voltage Accuracy ±30% ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time ≤500mS  (230Vac/115Vac, Full load) Hold up Time ≥20mS(230Vac, Full load)  ≥10mS(115Vac, Full load) Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT Voltage Range   Note 3 90Vac~264Vac Frequency Range 47Hz-63Hz Efficiency ( Typical) 230Vac input 86% 87% 88 % 90% 90.5% 91% AC Current (max.) <1.9A@115Vac  <1.2A@230Vac Inrush Current (Typical) <65A@230Vac      Cold start PROTECTION Over Power 110%~180% rated power, hiccup mode, auto recovery Over Current 110%~160% of rated current, hiccup mode, auto recovery Over Voltage 5.75~6.9V 13.8~16.2V 18.75~21.75V 28.8~33.6V 41.4~48.6V 55.2~64.8V Protection type: Constant voltage, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -30℃~70℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC   (Note 4) Safety Standards UL62368-1, IEC/EN62368-1 Withstand Voltage Primary-Secondary:3..0KVac/10mA.; Primary-PE:1.5KVac/10mA; Secondary-PE:0.5KVdc/10mA . Leakage Current Input—output:<0.25mA     Input—PE:<0.75mA  (@240Vac/63Hz) Isolation Resistance 100M ohms EMI Conduction&Radiation Compliance to EN55032 Class B Harmonic Current Compliance to EN61000-3-2,CLASS A EMS Immunity Compliance to EN61000-4-2,3,4,6,8,11 OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 129*97*30mm Packing 30pcs/CTN Cooling method Cooling by free air flow NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • LPD-150-X Power Supply
    LPD-150-X
    Ø  Universal AC input (90~264Vac) Ø  No load power consumption < 0.5W Ø  High efficiency, long life and high reliability Ø  Withstand 300Vac surge input for 5s Ø  Output protections: OLP/SCP/OVP/OPP Ø  Wide operating ambient temp (-30℃~70℃) Ø  Altitude up to 5000m Ø  All using 105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  1U low profile Ø  3 years warranty MODEL LPD-150-12 LPD-150-15 LPD-150-24 LPD-150-36 LPD-150-48 OUTPUT DC Output 12V 15V 24V 36V 48V Rated Current 12.5A 10A 6.25A 4.17A 3.125A Current Range     Note 1 0~12.5A 0~10A 0~6.25A 0~4.17A 0~3.125A Rated Power 150W 150W 150W 150W 150W Ripple and Noise @25C Note 2 150mV 150mV 200mV 200mV 200mV Voltage ADJ.  Range 10.8~13.2V 13.5~16.5V 21.6~26.4V 32.4~39.6V 43.2~52.8V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±0.5% Set-up Time ≤600ms/30ms (230Vac/115Vac input, Full load) Hold up Time ≥20mS(230Vac input, Full load)     Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT Voltage Range   90~264Vac  120-370VDC Frequency Range 47Hz~63Hz Efficiency ( Typical) @230Vac 84% 86% 88% 88% 89% AC Current (max.) ≤3A(115Vac)  /  ≤1.7A(230Vac) Inrush Current (Typical) ≤40A@220Vac   Cold start Leakage Current Input—output:<0.25mA ; Input—PG:<0.75mA   (Input 240Vac, 63Hz) PROTECTION Over current 120%~180% of rated current, Hiccup mode, auto recovery Over power 120%~180% of rated power, Hiccup mode, auto recovery Over voltage 120%~150% of rated output voltage, constant voltage, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -30℃~70℃;  20%~90%RH  No condensing Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards UL62368-1, IEC/EN62368-1 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance 100M ohms EMC Emission Compliance to EN55032 Class B EMC Immunity Compliance to EN61000-4-2,3,4,6,8,11 OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 159*97*30mm Packing 20pcs/CTN Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • LPD-200-X Power Supply
    LPD-200-X
    Ø  AC input selectable by switch (115Vac/230Vac) Ø  High efficiency, long life and high reliability Ø  Output protections: OLP/SCP/OVP/OPP Ø  Wide operating ambient temp (-25℃~70℃) Ø  100% full load burn-in test Ø  Altitude up to 5000m Ø  1U low profile Ø  Cooling by free air convection Ø  3 years warranty MODEL LPD-200-12 LPD-200-24 LPD-200-36 LPD-200-48 OUTPUT DC Output 12V 24V 36V 48V Rated Current 16.67A 8.33A 5.56A 4.17A Current Range     Note 1 0~16.67A 0~8.33A 0~5.56A 0~4.17A Rated Power 200W 200W 200W 200W Ripple and Noise  Note 2 0~70℃ ≤150mV ≤150mV ≤200mV ≤200mV -25℃ ≤300mV ≤300mV ≤400mV ≤400mV Voltage ADJ.  Range 10.2~13.8V 21.6~28.8V 32.4~39.6V 43.2~52.8V Voltage Accuracy ±1.5% ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% ±0.5% Set-up Time ≤2.0S/50mS (230/115Vac input, Full load) Hold up Time ≥16mS(230Vac input, Full load)    ≥12mS(115Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT Voltage Range   90Vac~132Vac/180Vac~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) @230Vac ≥86.5% ≥88.5% ≥89% ≥89.5% AC Current (max.) <4.0 A@ 115Vac   ;   <2.2A @ 230Vac 2.5A Inrush Current (Typical) <60A@ 115/230Vac   Cold start Leakage Current Input—output:<0.25mA ; Input—PG:<2.0mA   (Input 240Vac) PROTECTION Over current 18.33~30.0A 9.17~15.0A 6.11~10A 4.58~7.5A Protection type: Hiccup mode, auto recovery Over power 220~360W 220~360W 220~360W 220~360W Protection type: Hiccup mode, auto recovery Over voltage 13.8~16.2V 28.8~33.6V 41.4~46.8V 55.2~64.8V Protection type: Constant voltage, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃;  20%~90%RH  No condensing Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards UL62368-1, IEC/EN62368-1 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:2.0KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance 10M ohms EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11 OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 190*99*30mm Packing 20pcs/CTN Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • LPD-350-X Power Supply
    LPD-350-X
    Ø  AC input selectable by switch (115Vac/230Vac) Ø  High efficiency, long life and high reliability Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temp (-25℃~70℃) Ø  Altitude up to 5000m Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  3 years warranty SPECIFICATION MODEL LPD-350-12 LPD-350-24 OUTPUT DC Output 12V 24V Rated Current 29.17A 14.58A Current Range     0~29.17A 0~14.58A Ripple and Noise  Note 2 0~70℃ ≤150mV ≤150mV -25℃ ≤300mV ≤300mV Voltage ADJ. Range 10.2~13.8V 21.6~28.8V Voltage Accuracy ±1.5% ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% ±0.5% Set-up Time ≤2.3S Full load Hold up Time ≥12mS/115Vac input, Full load; ≥16mS/230Vac input, Full load Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT VoltageRange   90Vac~132Vac/180Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency @230Vac input ≥85% ≥87% AC Current (max.) <6.8A/115Vac ; <3.4A/230Vac 2.5A Inrush Current ﹤60A@ 115Vac/230Vac  Cold start Leakage Current Input—output:<0.25mA    Input—PG:<2.0mA (Input 240Vac) PROTECTION Over Load 30.63~43.75A 15.31~21.88A Protection type: Hiccup mode, auto recovery Over Power 367.5~525W 367.5~525W Protection type: Hiccup mode, auto recovery Over voltage 13.8~16.2V 28.8~33.6V Protection type: Constant voltage, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards GB4943 / EN60950 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:2.0KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance 10M ohms EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 190*99*30mm Packing TBD Cooling method Cooling by forced air (Built-in DC fan) NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com
  • PSF-550S industry power supply
    PSF-550S
    Ø  Universal input 80~264Vac or 113~370Vdc Ø  Built-in Active PFC, PF≥0.95 Ø  400W convention, 550W forced air Ø  No load power consumption<0.5W by PS­_ON/OFF Ø  Extremely low leakage current≤0.1mA Ø  12V/0.5A fan supply Ø  Output protections: SCP/OVP/OCP/OTP Ø  Wide operating ambient temperature (-40℃~70℃) Ø  Operating altitude up to 5000m Ø  5’’*3’’ Compact size Ø  Meet medical safety(2*MOPP) Ø  Fit for Class I & Class II configuration Ø  3 years warranty MODEL PSF-550S-12 PSF-550S-24 PSF-550S-36 PSF-550S-48 PSF-550S-54 OUTPUT DC Output 12V 24V 36V 48V 54V Rated Current (Convection) 33.4A 16.7A 11.1A 8.34A 7.4A Rated Current (16CFM forced air) 41.7A 22.9A 15.3A 11.46A 10.2A Rate Power(Convection) 400.8W 400.8W 399.6W 400.3W 399.6W Rate Power(16CFM forced air) 500.4W 549.6W 550.8W 550W 550.8W Ripple and Noise @25℃ Note 2 ≤200mVp-p Voltage ADJ.  Range 11.4~12.6V 22.8~25.2V 34.2~37.8V 45.6~50.4V 50.5~54V Voltage Accuracy ±2% Line Regulation ±1.0% Load Regulation ±1.0% Set-up Time ≤1.0S (230Vac input, Full load) Hold up Time 8mS @115/230Vac input   Full load Temperature Coefficient ±0.02%/℃ Overshoot <5.0% INPUT Voltage Range   Note 3 80~264Vac or 113~370Vdc Rated input voltage range 100~240Vac Frequency Range 47Hz-63Hz Efficiency ( Typical) 93.5% 94% 94% 94% 94% Power Factor(Typical) ≥0.95 @ 100~240Vac  full load AC Current (max.) <6.5A Inrush Current (Typical) <40A@115Vac ; <80A @ 230Vac      Cold start Leakage Current Touch current ≤0.1mA   @ ac input to dc output PROTECTION Over Current 110%~150%, hiccup mode, recovers automatically after fault condition is removed Over Voltage 110%~130%, constant voltage, recovers automatically after fault condition is removed Over temperature Shut down o/p voltage, recovers automatically after temperature goes down Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~70℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing Operating altitude (Note 3) 5000 meters SAFETY &EMC   (Note 4) Safety Standards IEC62368 / IEC60601 Withstand Voltage Primary-Secondary: 4KVac/5mA; Primary to PG: 2.0KVac/5mA; Secondary-PG: 1.5Vac/5mA Isolation Resistance 100M ohms EMI Conduction&Radiation Compliance to EN55032 Class B(Class I); Harmonic Current Compliance to EN61000-3-2, Class A EMS Immunity Compliance to EN61000-4-2,3,4,6,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃) 5V standby 5V/1A,tolerance ±2%, ripple : 120mVp-p(max.) PS_ON/OFF Power ON: PS-ON/OFF, "Hi" or " > 2 ~ 5V" ; Power OFF: PS-ON/OFF,"Low" or " < 0 ~ 0.5V" POWER GOOD / POWER FAIL 500ms>PG>10ms ; The TTL signal goes high with 10ms to 500ms delay after power set up ; The TTL signal goes low at least 1ms before Vo below 90% of rated value Dimension  (L*W*H) 127*76.2*40.5mm (5’’*3’’*1.59’’ inch) Packing TBD Cooling method 400W free air convection; 550W with 16CFM forced air NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.     The ambient temperature derating of 0.5℃/100m for operating altitude higher than 2000m. 4. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 
    A total of

    1

    pages
#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #