PD-50-X-D
Ø No Load power consumption<0.5W Ø Universal AC input range Ø Miniature size,high power density,high efficiency,long life and high reliability Ø Withstand 300VA surge input for 5 sec. Ø Output protections: OLP/OVP/SCP Ø Wide operating ambient temp (-25℃~70℃),100% @50℃、70%@70℃ Ø All using105℃long life electrolytic capacitors. Ø 100% full load burn-in test Ø Easy assembling from top side Ø PCB soldering side with conformal coating Ø Suitable for critical applications Ø 3 years warranty MODEL PD-50-5-D PD-50-12-D PD-50-24-DII OUTPUT DC Output 5V 12V 24V Rated Current 8A 4.2A 2.2A Current Range 0~8A 0~4.2A 0~2.2A Ripple and Noise (-25℃~70℃) Note 2 <80mV <120mV <200mV Voltage ADJ. Range 4.75~5.5V 11.4~13.2V 22.8V-26.4V Voltage Accuracy ±3.0% ±3.0% ±3.0% Line Regulation ±0.5% ±0.5% ±0.5% Load Regulation ±1.0% ±1.0% ±1.0% Set-up Time <1.5S (230Vac input, Full load) Hold up Time >50mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range 90Vac~264Vac,127~370Vdc Frequency Range 47Hz~63Hz Efficiency ( Typical) 80% 84.5% 87% AC Current (max.) <1.3A Inrush Current (Typical) <40A@230Vac Cold start Leakage Current Input—output:<0.25mA Input—PG:<3.5mA PROTECTION Over Load 105%~150% of rated output current, constant power Over power 105%~150% of rated output current, constant power Over Voltage 115%~150% of rated output voltage, Constant Voltage Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards UL62368-1; IEC62368-1; EN62368-1 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance ≥100M ohms EMC Emission Compliance to EN55032 Class B EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 99×82×35mm Packing 40PCS/CTN, 12.8KGS, 0.043CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.