LPD-100-X
Ø Universal AC input: 90~ 264Vac Ø Can bear 300Vac for 5s Ø No load power consumption<0.5W Ø High efficiency, long life and high reliability Ø Output protections: OCP/OVP/SCP Ø Wide operating ambient temperature (-30℃~70℃) Ø Altitude up to 5000m Ø All using 105℃ long life electrolytic capacitors. Ø 100% full load burn-in test Ø 1 U low profile Ø 3 years warranty MODEL LPD-100-5 LPD-100-12 LPD-100-15 LPD-100-24 LPD-100-36 LPD-100-48 OUTPUT DC Output 5V 12V 15V 24V 36V 48V Rated Current 18A 8.5A 7A 4.5A 3A 2.3A Current Range 0~18A 0~8.5A 0~7A 0~4.5A 0~3A 0~2.3A Rated Power 90W 102W 105W 108W 108W 110.4W Ripple and Noise (note1) 120 mV 150mV 150mV 200mV 200mV 200mV Voltage ADJ. Range 4.5~5.5V 10.8~13.2V 13.5~16.5V 21.6~26.4V 32.4~39.6V 43.2~52.8V Voltage Accuracy ±30% ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time ≤500mS (230Vac/115Vac, Full load) Hold up Time ≥20mS(230Vac, Full load) ≥10mS(115Vac, Full load) Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT Voltage Range Note 3 90Vac~264Vac Frequency Range 47Hz-63Hz Efficiency ( Typical) 230Vac input 86% 87% 88 % 90% 90.5% 91% AC Current (max.) <1.9A@115Vac <1.2A@230Vac Inrush Current (Typical) <65A@230Vac Cold start PROTECTION Over Power 110%~180% rated power, hiccup mode, auto recovery Over Current 110%~160% of rated current, hiccup mode, auto recovery Over Voltage 5.75~6.9V 13.8~16.2V 18.75~21.75V 28.8~33.6V 41.4~48.6V 55.2~64.8V Protection type: Constant voltage, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -30℃~70℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC (Note 4) Safety Standards UL62368-1, IEC/EN62368-1 Withstand Voltage Primary-Secondary:3..0KVac/10mA.; Primary-PE:1.5KVac/10mA; Secondary-PE:0.5KVdc/10mA . Leakage Current Input—output:<0.25mA Input—PE:<0.75mA (@240Vac/63Hz) Isolation Resistance 100M ohms EMI Conduction&Radiation Compliance to EN55032 Class B Harmonic Current Compliance to EN61000-3-2,CLASS A EMS Immunity Compliance to EN61000-4-2,3,4,6,8,11 OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 129*97*30mm Packing 30pcs/CTN Cooling method Cooling by free air flow NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.