PS-60-X
Ø Universal AC input/ Full range Ø High Efficiency, low power consumption Ø No load power comsumption<=0.5W Ø Output protections: SCP/OVP/ OLP Ø Wide operating ambient temperature (-25℃~70℃) Ø All using 105℃ long life electrolytic capacitors. Ø 100% full load burn-in test Ø 3 years warranty MODEL PS-60-5 PS-60-12 PS-60-15 PS-60-24 PS-60-48 OUTPUT DC Output 5.0V 12.0V 15.0V 24.0V 48.0V Rated Current 8.0A 4.5A 3.6A 2.5 A 1.25A Ripple and Noise Note 2 0~70℃ <50mV <120mV <120mV <120mV <240mV -25℃~0℃ <200mV <300mV <300mV <300mV <360mV Voltage ADJ. Range -5% ~ +10% of rated voltage Voltage Accuracy ±3.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤1.0S (230Vac input, Full load) Hold up Time ≥20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange Note 3 90Vac~264Vac, 127Vdc~370Vdc FrequencyRange 47Hz-63Hz Efficiency ( Typical) 115Vac input 78% 83% 84% 87% 85% 230Vac input 82% 85% 85% 87% 88% AC Current (max.) <1.5A Inrush Current (Typical) <30A@120Vac <60A@230Vac Cold start Leakage Current <0.25mA PROTECTION Over Load 105%~180% of rated output current, hiccup mode,auto recovery Over Voltage 110%~150% of rated output voltage, Constant voltage, Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC (Note 4) Safety Standards UL60950-1; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA . Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022, ClassB Harmonic Current Compliance to EN61000-3-2,-3 EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 101.6×50.8×30mm Packing 60PCS/CTN, 12KGS, 0.024CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. We focus on your industrial power supply project needs, Offering reliable quality and high cost-effective products is always our top priority. Effective Communication within 24 hours.