other
Search
Home Search
  • PS-60-X power supply
    PS-60-X
    Ø  Universal AC input/ Full range Ø  High Efficiency, low power consumption Ø  No load power comsumption<=0.5W Ø  Output protections: SCP/OVP/ OLP Ø  Wide operating ambient temperature (-25℃~70℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø 3 years warranty  MODEL PS-60-5 PS-60-12 PS-60-15 PS-60-24 PS-60-48 OUTPUT DC Output 5.0V 12.0V 15.0V 24.0V 48.0V Rated Current 8.0A 4.5A 3.6A 2.5 A 1.25A Ripple and Noise  Note 2 0~70℃ <50mV <120mV <120mV <120mV <240mV -25℃~0℃ <200mV <300mV <300mV <300mV <360mV Voltage ADJ. Range -5% ~ +10% of rated voltage Voltage Accuracy ±3.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤1.0S (230Vac input, Full load) Hold up Time ≥20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange  Note 3 90Vac~264Vac, 127Vdc~370Vdc FrequencyRange 47Hz-63Hz Efficiency ( Typical) 115Vac input 78% 83% 84% 87% 85% 230Vac input 82% 85% 85% 87% 88% AC Current (max.) <1.5A Inrush Current (Typical) <30A@120Vac   <60A@230Vac     Cold start Leakage Current <0.25mA PROTECTION Over Load 105%~180% of rated output current, hiccup mode,auto recovery Over Voltage 110%~150% of rated output voltage, Constant voltage, Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 4) Safety Standards UL60950-1; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA . Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022, ClassB Harmonic Current Compliance to EN61000-3-2,-3 EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 101.6×50.8×30mm Packing 60PCS/CTN, 12KGS, 0.024CBM Cooling method Cooling by free air convection NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.   We focus on your industrial power supply project needs, Offering reliable quality and high cost-effective products is always our top priority. Effective Communication within 24 hours.
  • PSF-125-X power supply
    PSF-125-X
    Ø  Universal AC input/ Full range Ø  High power density,High effiency and reliability Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temperature (-20℃~70℃) Ø  Build-in remote sense function Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  3 years warranty MODEL PSF-125-5 GZM-H25S8.5 PSF-125-12 GZM-H25S12II PSF-125-15 PSF-125-24 PSF-125-36 PSF-125-48 OUTPUT DC Output 5V 8.5V 12V 12V 15V 24V 36V 48V Rated Current 20A 3A 10.5A 2 A 8.4A 5.2A 3.5A 2.6A CurrentRange   Note 1 0~20A 0~3A 0~10.5A 0~2A 0~8.4A 0~5.2A 0~3.5A 0~2.6A Ripple and Noise Note 2 100mV 85mV 100mV 120mV 100mV 100 mV 120 mV 150 mV Voltage ADJ. Range ±10% of rated output voltage Voltage Accuracy ±2.0% ±3.0% ±2.0% ±5.0% ±2.0% ±2.0% ±2.0% ±2.0% Line Regulation ±0.5% ±0.5% ±0.5% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% Load Regulation ±2.0% ±2.0% ±2.0% ±1.0% ±2.0% ±2.0% ±2.0% ±2.0% Set-up Time <=1200mS (230Vac input, Full load)   <=2500mS (115Vac input, Full load) Hold up Time >=17mS(115/230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshootand Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac,127Vdc~370Vdc FrequencyRange 47Hz--63Hz Power Factor(Typical) PF>0.98/115VAC   PF>0.93/230VAC Efficiency ( Typical) 82%/115Vac 85%/115Vac 85%/115Vac 85%/20Vac 86%/115Vacin 86%/115Vac 84%/230Vac 87%/230Vac 87%/230Vac 87%/230Vac 88%/230Vac 88%/230Vac AC Current (max.) 1.5A 0.5A 2.5A 1.5A 0.3A 1.5A 1.5A 1.5A 1.5A Inrush Current (Typical) 60A@230Vac  30A@115Vac  Cold start Leakage Current <3.5mA PROTECTION Over Current 105%~150% of rated output current, hiccup mode, auto recovery Over Voltage 120%~150% of rated output voltage,hiccup mode Short Circuit Auto recovery ENVIRONMENT OperatingambTemp& Hum -20℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   Note 3 Safety Standards GB4943-2011; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA .Secondary-PG:0.5KVDC;≤10mA . Isolation Resistance 100M ohms EMI Conduction&Radiation Compliance to EN55022(CISPR22)ClassB Harmonic Current Compliance to EN61000-3-2,-3 EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA OTHERS MTBF (MIL-HDBK-217F) More than 100,000Hrs (25℃, Full load) Dimension (L*W*H) 127×76×30.5mm Packing 21PCS/CTN, 8.46KGS, 0.015CBM Cooling method Cooling by free air convection NOTE 1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com Focus on the development of Industrial power supply for many years,make efforts to meet customers' requirements and search for long-term cooperation.24 hours online service affiliates you to contact us.
    A total of

    1

    pages
#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #