  • PD-H35SX power supply
    PD-H35SX
    Ø  No Load power consumption<0.5W Ø  High AC input Ø  Miniature size,high power density,high efficiency,long life and high reliability Ø  Withstand 300VA surge input for 5 sec. Ø  Output protections: OLP/OVP/SCP/OPP Ø  Wide operating ambient temp (-25℃~70℃),100% @50℃、70%@70℃ Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Suitable for critical applications Ø  3 years warranty     SPECIFICATION                                              MODEL PD-H35S12 OUTPUT DC Output   Rated Current 2.6A Current Range      0~2.6A Ripple and Noise  Note 2 -25~70℃   Voltage ADJ.  Range 11.4~12.6V Voltage Accuracy ±2.0% Line Regulation ±1.0% Load Regulation ±2.0% Set-up Time <1.0S (230Vac input, Full load) Hold up Time >20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range     Frequency Range 47Hz~63Hz Efficiency ( Typical) 82% AC Current (max.) 0.7A 2.5A Inrush Current (Typical) <40A@230Vac      Cold start Leakage Current Input—output:<3.5mA     Input—PG:<0.25mA PROTECTION Over Load   Over power 37.8~54W, constant power Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum.   Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards   Withstand Voltage Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022 ClassB; FCC PART15 B EMS Immunity Compliance to EN61000-4-2,4,5,8,11; OTHERS MTBF (MIL-HDBK-217F)   Dimension  (L*W*H) 94.5×51.5×29.5mm Packing 48PCS/CTN, 10.42KGS, 0.03CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. 4. Powerld offer accessories for Din-35 rail bar. Please contact sales staff for details. We are professional manufacturer engaged in the research, development, production, sale and service of Industrial power supply,We sincerely look forward to cooperating with you and creating the future together!
  • DG-75-X din rail power supply
    DG-75-X
    Ø  Universal AC input range(85~264Vac) Ø  Support 1+1 or N+1 redundant system(suggest to use redundancy modules.) Ø  Built-in active PFC,PF>0.95 Ø  High efficiency up to 91% Ø  Built-in current sharing function Ø  Built-in current limiting circuit Ø  Output protections: OVP/OLP/SCP/OTP Ø  Wide operating ambient temp (-25℃~70℃) Ø  150% peak load capacity Ø  Easy Fuse Tripping due to High Overload Current Ø  Excellent Partial Load Efficiency Ø  Built-in DC OK relay contact Ø  Can be installed on TS-35/7.5 or TS-35/15 Ø  100% full load burn-in test Ø  Suitable for critical applications Ø  Ultra-slim, 32mm width Ø  3 years warranty SPECIFICATION                                               MODEL DG-75-12 DG-75-24 DG-75-48 OUTPUT DC Output 12V 24V 48V Rated Current 6.3A  3.2A 1.6A CurrentRange    Note 1 0~6.3A 0~3.2A 0~1.6A Ripple and Noise  Note 2 0~70℃ ≤100mV ≤120mV ≤120mV -25℃ ≤200mV ≤240mV ≤240mV Voltage ADJ. Range 12~14V 24~28V 48~56V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <250mS@230Vac ; <500mS@100Vac Hold up Time ≥20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   85Vac~264Vac, 127Vdc-360Vdc FrequencyRange 47Hz~63Hz Power Factor (typical) 0.99/100Vac    0.95/230Vac Efficiency ( Typical) 88% 91% 91% AC Current (max.) <0.95 A/100Vac       <0.45A/230Vac Inrush Current (Typical) <30A/100Vac     <60A/230Vac  Cold start Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA PROTECTION Over Load 110%~150% of rated current, Constant power limiting for some time(150% of rated current, last 3S) then PS stop working for 7S,after 7S,if the load <=rated current, PS will work normally, auto recovery Over voltage 15~18V 29~33V 58~65V Protection type: Hiccup mode, Auto recovery Over temperature 100±5℃, detect on heat sink of power transistor; shut down O/P, auto recovery after temperature goes down. Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 5%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards meet UL508, UL60950, EN60950 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:2.5KVac;≤10mA. Secondary-PG:0.5KVac≤10mA. Isolation Resistance ≥100M ohms EMC Emission Compliance to EN55022, EN55024, FCC PART 15 Class B Harmonic Current Compliance to EN61000-3-2, CLASS A EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 300,000Hrs (25℃, Full load) Dimension (L*W*H) 124*119*32mm Packing 28pcs/CTN,17.6Kg, 0.04cbm Cooling method Cooling by free air convection Additional function Power boost 150% of rated current DC OK V On: when output voltage is up to 90% of rated output voltage V Off: when output voltage is down to 80% of rated output voltage DC OK relay contact rating Max 30V/1Aor 60V/0.3Aor 30Vac/0.3AResistive load Parallel function support NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com DIN rail power supply is a kind of switching power supply, which can convert unstable input voltage into stable output voltage. We can meet all industry standards of DIN rail power supply. Learn more, follow us, and leave us a message.
  • PSF-200-X power supply
    PSF-200-X
    Ø  Universal AC input/ Full range Ø  Built-in Active PFC function Ø  Withstand 300Vac surge input for 5 sec. Ø  High efficiency up to 90%(typ) Ø  Output protections: OLP/OVP/SCP/OPP Ø  Wide operating ambient temperature (-20℃~70℃) Ø  All using105℃long life electrolytic capacitors. Ø  Free air convection for 150W and 200W with 20.5CFM forced air Ø  100% full load burn-in test Ø 5’’*3’’ compact size Ø  3 years warranty MODEL PSF-200-12 GZM-H25S12II PSF-200-24 PSF-200-27 PSF-200-48 OUTPUT DC Output 12V 8.5V 12V 12V 24V 27V 48V Rated Current 16.6A 3A 10.5A 2 A 8.4A 7.4A 4.167A CurrentRange(convection)    0~12.5A 0~3A 0~10.5A 0~2A 0~6.25A 0~5.5A 0~3.13A CurrentRange(20.5CFM fan) 0~16.6A 0~8.4A 0~7.4A 0~4.167A Ripple and Noise Note 20<Ta≤70℃ 0<Ta≤70℃ 120mVp-p 85mV 100mV 120mV 200 mVp-p 100 mVp-p 120 mVp-p -20≤Ta≤0℃ 200 mVp-p 200 mVp-p 150 mVp-p 240 mVp-p Voltage ADJ. Range ±10% of rated output voltage Voltage Accuracy ±1.0% ±3.0% ±5.0% ±2.0% ±2.0% Line Regulation ±0.5% ±0.5% ±1.0% ±0.5% ±0.5% Load Regulation ±1.0% ±2.0% ±1.0% ±2.0% ±2.0% Set-up Time ≤2S (230VAC input, Full load)& ≤4S (115VAC input, Full load) Hold up Time ≥16mS/150W 10mS/200W(115 / 230VAC IN AT FULL LOAD) Temperature Coefficient ±0.03%/℃ Overshootand Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac,127Vdc~370Vdc FrequencyRange 47Hz--63Hz Power Factor(Typical) PF>0.98/115VAC   PF>0.95/230VAC Efficiency ( Typical) ≥89% ≥89% ≥89% ≥90% AC Current (max.) <3A 2.5A 1.5A 0.3A 1.5A 1.5A 1.5A 1.5A Inrush Current (Typical) <50A@230Vac  <30A@115Vac  Cold start Leakage Current ≤3.5mA PROTECTION Over Current 105%~150% of rated output current, hiccup mode, auto recovery Over Power 105%~150% of rated output current, hiccup mode, auto recovery Over Voltage 125%~150% of rated output voltage, hiccup mode, auto recovery Short Circuit Long-term, Auto recovery ENVIRONMENT OperatingambTemp& Hum -20℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   Note 3 Safety Standards UL60950-1; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA .Secondary-PG:0.5KVDC;≤10mA . Isolation Resistance 100M ohms EMI Conduction&Radiation Compliance to EN55022,EN55024 ClassB Harmonic Current Compliance to EN61000-3-2,-3 EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11;EN55024,EN61000-6-2heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 128×76.5×34.6mm(5’’*3’’) Packing 21PCS/CTN, 8.46KGS, 0.015CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. We focus on your industrial power supply project needs, Offering reliable quality and high cost-effective products is always our top priority. Effective Communication within 24 hours.
  • LPD-150-X Power Supply
    LPD-150-X
    Ø  Universal AC input (90~264Vac) Ø  No load power consumption < 0.5W Ø  High efficiency, long life and high reliability Ø  Withstand 300Vac surge input for 5s Ø  Output protections: OLP/SCP/OVP/OPP Ø  Wide operating ambient temp (-30℃~70℃) Ø  Altitude up to 5000m Ø  All using 105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  1U low profile Ø  3 years warranty MODEL LPD-150-12 LPD-150-15 LPD-150-24 LPD-150-36 LPD-150-48 OUTPUT DC Output 12V 15V 24V 36V 48V Rated Current 12.5A 10A 6.25A 4.17A 3.125A Current Range     Note 1 0~12.5A 0~10A 0~6.25A 0~4.17A 0~3.125A Rated Power 150W 150W 150W 150W 150W Ripple and Noise @25C Note 2 150mV 150mV 200mV 200mV 200mV Voltage ADJ.  Range 10.8~13.2V 13.5~16.5V 21.6~26.4V 32.4~39.6V 43.2~52.8V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±0.5% Set-up Time ≤600ms/30ms (230Vac/115Vac input, Full load) Hold up Time ≥20mS(230Vac input, Full load)     Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT Voltage Range   90~264Vac  120-370VDC Frequency Range 47Hz~63Hz Efficiency ( Typical) @230Vac 84% 86% 88% 88% 89% AC Current (max.) ≤3A(115Vac)  /  ≤1.7A(230Vac) Inrush Current (Typical) ≤40A@220Vac   Cold start Leakage Current Input—output:<0.25mA ; Input—PG:<0.75mA   (Input 240Vac, 63Hz) PROTECTION Over current 120%~180% of rated current, Hiccup mode, auto recovery Over power 120%~180% of rated power, Hiccup mode, auto recovery Over voltage 120%~150% of rated output voltage, constant voltage, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -30℃~70℃;  20%~90%RH  No condensing Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards UL62368-1, IEC/EN62368-1 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance 100M ohms EMC Emission Compliance to EN55032 Class B EMC Immunity Compliance to EN61000-4-2,3,4,6,8,11 OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 159*97*30mm Packing 20pcs/CTN Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • LPD-350-X Power Supply
    LPD-350-X
    Ø  AC input selectable by switch (115Vac/230Vac) Ø  High efficiency, long life and high reliability Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temp (-25℃~70℃) Ø  Altitude up to 5000m Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  3 years warranty SPECIFICATION MODEL LPD-350-12 LPD-350-24 OUTPUT DC Output 12V 24V Rated Current 29.17A 14.58A Current Range     0~29.17A 0~14.58A Ripple and Noise  Note 2 0~70℃ ≤150mV ≤150mV -25℃ ≤300mV ≤300mV Voltage ADJ. Range 10.2~13.8V 21.6~28.8V Voltage Accuracy ±1.5% ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% ±0.5% Set-up Time ≤2.3S Full load Hold up Time ≥12mS/115Vac input, Full load; ≥16mS/230Vac input, Full load Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT VoltageRange   90Vac~132Vac/180Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency @230Vac input ≥85% ≥87% AC Current (max.) <6.8A/115Vac ; <3.4A/230Vac 2.5A Inrush Current ﹤60A@ 115Vac/230Vac  Cold start Leakage Current Input—output:<0.25mA    Input—PG:<2.0mA (Input 240Vac) PROTECTION Over Load 30.63~43.75A 15.31~21.88A Protection type: Hiccup mode, auto recovery Over Power 367.5~525W 367.5~525W Protection type: Hiccup mode, auto recovery Over voltage 13.8~16.2V 28.8~33.6V Protection type: Constant voltage, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards GB4943 / EN60950 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:2.0KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance 10M ohms EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 190*99*30mm Packing TBD Cooling method Cooling by forced air (Built-in DC fan) NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com
  • DG-360-X Din rail power supply
    DG-360-X
    Ø  Universal AC input range(85~264Vac) Ø  Support 1+1 or N+1 redundant system(suggest to use redundancy modules.) Ø  Built-in active PFC,PF>0.95 Ø  High efficiency up to 93% Ø  Built-in current sharing function Ø  Built-in current limiting circuit Ø  Output protections: OVP/OLP/SCP/OTP Ø  Wide operating ambient temp (-25℃~70℃) Ø  150%(540W) peak load capacity Ø  Excellent Partial Load Efficiency Ø  Built-in DC OK relay contact Ø  Can be installed on TS-35/7.5 or TS-35/15 Ø  100% full load burn-in test Ø  Suitable for critical applications Ø  Ultra-slim, 50mm width Ø  Free air convection Ø  3 years warranty SPECIFICATION MODEL DG-360-24 DG-360-36 DG-360-48 OUTPUT DC Output 24V 36V 48V Rated Current 15A 10A 7.5A CurrentRange    Note 1 0~15A 0~10A 0~7.5A Ripple and Noise  Note 2 0~70℃ ≤240mV ≤240mV ≤480mV -25℃ ≤480mV ≤480mV ≤720mV Voltage ADJ. Range 24~28V 34~37.5V 48~56V Voltage Accuracy ±3.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <3S@230Vac  Hold up Time ≥20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   85Vac~264Vac, 127Vdc-375Vdc FrequencyRange 47Hz~63Hz Power Factor (typical) 0.99/110Vac    0.95/230Vac  full load Efficiency ( Typical) at 230Vac ≥93% ≥92.5% ≥92.5% AC Current (max.) <5A/100Vac     <2.5A/230Vac Inrush Current (Typical) <20A/110Vac,<40A/230Vac  Cold start Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA PROTECTION Over Load 110%~150% of rated current, Constant current limiting for some time(150% of rated current, last 3S) then PS stop working for 7S,after 7S,if the load <=rated current, PS will work normally, auto recovery Over voltage 29~33V, constant voltage, Auto recovery 39~43V, constant voltage Auto recovery 58~63V, constant voltage Auto recovery Over temperature 115±5℃, detect on heat sink of power transistor; shut down O/P, auto recovery after temperature goes down. Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 5%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards meet UL508, UL60950, EN60950 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:2.5KVac/10mA. Secondary-PG: 0.5KVac/20mA. Output-DC/OK: 0.5KVac/1mA Isolation Resistance 10Mohms EMC Emission Compliance to EN55022, EN55024, FCC PART 15 Class B Harmonic Current Compliance to EN61000-3-2, CLASS A EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 300,000Hrs (25℃, Full load) Dimension (L*W*H) 50*124*127mm Packing 12pcs/CTN, 11Kgs/CTN, 0.04cbm Cooling method Cooling by free air convection Additional function Power boost 150% of rated current Parallel function support DC-OK V On: when output voltage is up to 90% of rated output voltage V Off: when output voltage is down to 80% of rated output voltage DC-OK relay contact rating Max 30V/1Aor 60V/0.3Aor 30Vac/0.3AResistive load NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com. DIN rail power supply is a kind of switching power supply, which can convert unstable input voltage into stable output voltage. We can meet all industry standards of DIN rail power supply. Learn more, follow us, and leave us a message.
  • VAT-A200L-X-D power supply
    VAT-A200L-X-D
    Ø  High AC input (180-264Vac) Ø  High Efficiency up to 86% Ø  Output protections: SCP/OLP/OPP Ø  Wide operating ambient temperature (-40℃~65℃) Ø  Operating altitude up to5000m Ø  All using105℃long life electrolytic capacitors. Ø  Can work @-40℃, 220Vac input, full load Ø  100% full load burn-in test Ø  1 year warranty MODEL VAT-A200L-5-D OUTPUT DC Output 5V Rated Current 40A CurrentRange    Note 1 0~40A Peak load 44A (last 100mS, 220Vac input) Ripple and Noise  Note 2 25~65℃ ≤150mV 0~25℃ ≤200mV Voltage ADJ. Range 3.3~5.0V Voltage Accuracy ±2.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2S (220Vac input, full load) Hold up Time ≥10mS (220Vac input, full load) Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT VoltageRange   180Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) ≥86%(220Vac input, 80% load) AC Current (max.) <3A Inrush Current (Typical) <50A@220Vac     Cold start Leakage Current Input—output:<0.25mA    Input—PG:<3.5 mA (264Vac input, 63Hz) PROTECTION Over Power 210~300W, hiccup mode, auto recovery Over Current 42~60A, hiccup mode, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~65℃; 20%~90%RH No condensing (pls refer to derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards GB4943/ EN60950 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 10Mohms EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11 OTHERS MTBF (MIL-HDBK-217F) More than 100,000Hrs (25℃, Full load) Dimension (L*W*H) 190×84×30mm Packing 24pcs/CTN Cooling method Free air convection NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and 25℃of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. We provide high-quality LED power supplies for indoor and outdoor, and a variety of specifications and models of LED power supplies are optional, suitable for specific lighting applications in multiple fields.
  • GST-H150SX-M power supply
    GST-H150SX-M
    Ø  High Efficiency, and High reliability Ø  Output protections: OCP/OPP/SCP Ø  Wide operating ambient temperature (-10℃~50℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  1 years warranty SPECIFICATION MODEL GST-H150S8.5-M GST-H150S12-M GST-H150S24-M GST-H150S28-M GST-H150S36-M GST-H150S48-M OUTPUT DC Output 8.5V 12V 24V 28V 36V 48V Rated Current 17.5A 12.5A 6.0A 5.5A 4A 3.0A CurrentRange    0~17.5A 0~12.5A 0~6.0A 0~5.5A 0~4.0A 0~3.0A Ripple and Noise  Note 2 100Mv 120mV 200mV 200mV 200 mV 200mV Voltage ADJ. Range ±5% of rated output voltage Voltage Accuracy ±2.0 Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <=1.0S (220Vac input, Full load) Hold up Time >=20mS(220Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange  176Vac~265Vac FrequencyRange 47Hz~63Hz Efficiency (Typical) 220Vac 76% 80% 81% 82% 85% 85% AC Current (max.) 4.0A 2.0A 1.9A 2A 2.0A 1.8A 0.50A Inrush Current (Typical) 40A@220Vac  Cold start Leakage Current <3.5mA PROTECTION Over Current 105%~150% of rated output current, auto recovery Over Power 105%~150% of rated output current, auto recovery Shorted Circuit Long-term mode,auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -10℃~50℃; 20%~90%RH No condensing Storage Temp. & Hum. -25℃~85℃; 10%~95%RH No condensing SAFETY &EMC   Safety Standards EN60950-1 Withstand Voltage Primary-Secondary:1.5KVac; Primary-PG:1.5KVac; Secondary-PG:0.5KVDC Isolation Resistance 100M ohms OTHERS MTBF (MIL-HDBK-217F) More than 100,000Hrs (25℃, Full load) Dimension (L*W*H) 199×98×40mm Connection 7P/8.025mm barrier terminal block Cooling method Cooling by free air convection NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. Powerld enterprises is specialized in switching power supply since 1991, obtained ISO9001 certificate in 2002, ISO14001 certificate in 2006.As a professional switching power supply manufacturer,Powerld can supply a broad range of power supply,we can not only supply our customers with high quality products,but also our best service and fast delivery time.