other
Search
Home Search
  • PS-120-X power supply
    PS-120-X
    Ø  Universal input 80~264Vac or 113~370Vdc Ø  84W free air convection, 120W with 10CFM forced air Ø  High Efficiency, long life, high reliability Ø  Output protections: SCP/OVP/OCP/OPP Ø  Wide operating ambient temperature (-30℃~70℃) Ø  Operating altitude up to 4000m Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Meet Class I and Class II(no ground required) device Ø  No load power consumption ≤0.35W Ø  Built-in 12V/0.5A auxiliary output Ø  4’’*2’’ Compact size Ø 3 years warranty   MODEL PS-120-24 OUTPUT DC Output 24V Rated Current (free air convection) 3.5A (84W) Rated Current (10CFM forced air) 5A (120W) Ripple and Noise  Note 2 0~70℃ ≤100mV -30℃~0℃ ≤150mV Voltage ADJ. Range 22.8~25.2V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time ≤0.5S (110/220Vac input, Full load) Hold up Time ≥10Ms @110Vac input ; ≥40Ms @220Vac input  Full load Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <±5.0% INPUT VoltageRange  Note 3 80Vac~264Vac; 113~370Vdc Rated input voltage range 100~240Vac; 133~308Vdc FrequencyRange 47Hz-63Hz Efficiency ( Typical) 90% AC Current (max.) ≤2.5 A/110VAC  ≤1.5 A/220VAC Inrush Current (Typical) ≤30 A/110VAC  ≤60A/220Vac     Cold start Leakage Current Input to PG: ≤1mA   Input to output: ≤0.5mA (264Vac input, 63Hz) PROTECTION Over Current 5.75~7.5A, hiccup mode, auto recovery Over Power 138~180W, hiccup mode, auto recovery Over Voltage 26.4~31.2V, Constant voltage, auto recovery Shorted Circuit Long-term mode, auto recovery Function Fan Supply 12V @ 0.5A for driving a fan; tolerance ±15% ENVIRONMENT Operating amb. Temp. & Hum. -30℃~70℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 3) Safety Standards Meet UL62368, EN62368 Withstand Voltage Primary-Secondary:4KVac/5mA; Primary to PG: 2KVac/5mA; Secondary-PG: 1.5Vac/5mA Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55032 Class B Harmonic Current Compliance to EN61000-3-2, Class A EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 101.6×50.8×29mm (4’’*2’’*1.14’’) Packing 45PCS/CTN, 15.2KGS, 0.023CBM Cooling method 84W free air convection; 120W with 10CFM forced air NOTE 1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com Focus on the development of Industrial power supply for many years,make efforts to meet customers' requirements and search for long-term cooperation.24 hours online service affiliates you to contact us.
  • VAT-UP200U-X
    VAT-UP200U-X
    Ø  Universal AC input Ø  Built-in active PFC,PF>0.95 Ø  High efficiency, long life and high reliability Ø  Output protection: SCP/OLP/OVP/OPP Ø  Wide operating ambient temperature (-20~65℃) Ø  All using105℃long life electrolytic capacitor Ø  100% full load burn-in test Ø  3 years warranty MODEL VAT-UP200U-5 OUTPUT DC Output 5.0V Rated Current 40A CurrentRange    Note 1 0~40A Peak load 45A (50mS, 220Vac input) Ripple and Noise  Note 2 0~65℃ ≤250mV -20℃ ≤300mV Voltage ADJ. Range / Voltage Accuracy ±4.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2S (220VAC input, 40A) Hold up Time ≥5mS (220Vac input, 32A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac FrequencyRange 47Hz--63Hz Power Factor(Typical) PF>0.95/230VAC   full load Efficiency ( Typical) ≥89%(220VAC, 40A)    ≥87%(110VAC, 30A) AC Current (max.) <2A Inrush Current (Typical) <60A@230Vac Cold start Leakage Current Input—output:<0.25mA    Input—PG:<3.5Ma (264Vac, 63Hz) PROTECTION Over Load 44~65A, Hiccup mode, auto recovery Over power 220~320W, hiccup mode, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -20℃~65℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing Vibration 10 ~ 500Hz,2G10min./1cycle, period for 60min. each along X,Y, Z axes Withstand Voltage Primary-Secondary: 3.0KVac; ≤10mA .Primary-PG: 1.5KVac; ≤10mA. Secondary-PG: 0.5KVDC; ≤10mA. Isolation Resistance 10Mohms SAFETY&EMC (Note 3) EMI Conduction & Radiation Compliance to EN55022, EN55024, FCC PART 15  CLASS B Harmonic Current Compliance to EN61000-3-2, Class D EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 100,000Hrs (25℃, Full load) Dimension (L*W*H) 210×31.5×30mm Packing 49PCS/CTN, 15KGS, 0.04CBM Cooling method Cooling by air NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttp://www.powerld.com.cn.
  • VAT-HP260-X-C
    VAT-HP260-X-C
    Ø  High voltage input (176~264Vac) Ø  With Active PFC, PF>0.95 Ø  Surge 300Vac for 60S Ø  High Efficiency, long life and High reliability Ø  Output protections: OCP/SCP/OPP/OTP Ø  Wide operating ambient temperature (-40℃~50℃) Ø  Operating altitude up to5000m Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Fanless, quiet working Ø  PCB with conformal coating Ø  Low profile, 30mm        Ø  3 years warranty MODEL VAT-HP260-5.2-C OUTPUT DC Output 5.2V Rated Current 40A Current Range     Note 1 0~50A Peak load 55A Ripple and Noise  Note 2 0~50℃ ≤150mV -40~0℃ ≤400mV Voltage Accuracy@-40~50C ±3% Line Regulation ±0.5% Load Regulation ±2% Set-up Time @25℃ ≤2S (220Vac input,40A) Hold up Time ≥5mS (220Vac input,32A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <±5% INPUT Voltage Range   Note 3 176~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) 92%  (220Vac input,40A) AC Current (max.) <3.5A Inrush Current (Typical) <60A@220Vac      Cold start Power Factor @25℃ >0.95  (input 220Vac,40A) Stand by power consumption <4W Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA   (input 264Vac, 63Hz) PROTECTION Over Current 55~80A , hiccup mode, auto recovery Over Power 286~416W, hiccup mode, auto recovery Over Temperature 115℃+5℃(detect on temperature protector);shut down, auto recovery after ambient temperature goes down to 50℃(temperature protector goes down to 85℃+15℃) Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~50℃;  20%~90%RH  No condensing(refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC   (Note 3) Safety Standards GB4943 / EN60950 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 10M ohms EMI Conduction&Radiation Compliance to EN55022, EN55024, FCC PART 15   CLASS B Harmonic current Compliance to EN61000-3-2, Class D EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) >200000h (25℃, Full load) Dimension  (L*W*H) 133*55*30mm Packing 49PCS/CTN, 15KGS, 0.04CBM Cooling method Cooling by free air convection NOTE 1.   All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.   Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
    A total of

    3

    pages
#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #