  • PS-45-SX power supply
    PS-45-SX
    Ø  Universal AC input/ Full range (90~264Vac) Ø  High Efficiency, long life and high reliability Ø  Output protections: SCP/OVP/ OLP/OPP Ø  Wide operating ambient temperature (-10℃~60℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  3 years warranty  MODEL PS-45-S12 PS-45-S24 PS-45-S48 OUTPUT DC Output 12V 24V 48V Rated Current 3.7A 1.9A 1A Ripple and Noise  Note 2 0~60℃ ≤120mV ≤120mV ≤120mV -10℃~0℃ ≤200mV ≤200mV ≤200mV Voltage ADJ. Range 11.4~13.2V 22.8~26.4V 45.6~52.8V Voltage Accuracy ±3.0% Line Regulation ±1.0% Load Regulation ±3.0% Set-up Time ≤0.8S @ 230Vac   full load Hold up Time ≥60mS @ 230Vac  full load Temperature Coefficient ±0.05%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange  Note 3 90Vac~264Vac FrequencyRange 47Hz-63Hz Efficiency ( Typical) 220Vac input ≥82% ≥85% ≥86% AC Current (max.) <1A(115VAC)  <0.6A(230VAC) Inrush Current (Typical) <20A@115Vac   <45A@230Vac     Cold start Leakage Current Input to Output:≤0.25mA ; Input to PG:≤3.5mA PROTECTION Over Load 3.9~6.2A 2.0~3.2A 1.1~1.56A Protection type: Hiccup mode, auto recovery Over Voltage 13.8~16.2V 27.6~32.4V 55.2~64.8V Protection type: Constant voltage, Auto recovery Over Power 46.8~75W 48~75W 53~75W Protection type: Hiccup mode, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -10℃~60℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -25℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 4) Safety Standards UL60950-1; EN60950-1:2006 Withstand Voltage Input-Output:3.0KVac/10mA ; Output-PG: 1.5KVac/10mA;Output-PG: 0.5KVdc/10mA Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022 Class B EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 101.6×51×28mm Packing 60PCS/CTN, 11KGS, 0.024CBM Cooling method Cooling by free air convection NOTE 1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.   We are Industrial power supply manufacturer with competitive price and good quality,which are widely recognized and trusted by users and can meet social needs.
  • PD-75-X Power Supply
    PD-75-X
    Ø  No Load power consumption<0.5W Ø  Withstand 300VA surge input for 5 sec. Ø  High Efficiency, High reliability and long life Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temperature (-25℃~70℃) Ø  Operating altitude up to5000m Ø  All using105℃long life electrolytic capacitors. Ø  PCB soldering side with conformal coating Ø  100% full load burn-in test Ø  3 years warranty      SPECIFICATION                                              MODEL PD-75-5 PD-75-12 PD-75-15 PD-75-24 PD-75-48 OUTPUT DC Output 5V 12V 15V 24V 48V Rated Current 12A 6A 5A 3.2.A 1.6A Current Range     Note 1 0~12A 0~6A 0~5A 0~3.2A 0~1.6A Ripple and Noise Note 2 0~70℃ <50mV <80mV <80mV <80mV <120mV -25~0℃ <80mV <200mV <200mV <200mV <240mV Voltage ADJ.  Range 4.75~5.5V 11.4~13.2V 14.25~16.5V 22.8~26.4V 45.6~52.8V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time ≤1S(230Vac input, Full load) Hold up Time ≥20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   90Vac~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) 79% 84% 86% 86.5% 88% AC Current (max.) <2.5A Inrush Current (Typical) <60A@230Vac      Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA         (264Vac input, 63Hz) PROTECTION Over Load 12.6~18A 6.3~9A 5.25~7.5A 3.36~4.8A 1.7~2.43A Protection type: 5V, hiccup mode; others, constant power, Auto recovery Over Voltage 5.5~7.5V 13.2~18V 16.5~22.5V 26.4~36V 52.8~72V Protection type: constant voltage, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃;  20%~90%RH  No condensing((refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac/ 10mA .Primary-PG:1.5KVac/ 10mA. Secondary-PG:0.5KVDC/ 10mA. Isolation Resistance 100M ohms EMI Conduction& Radiation Compliance to EN55022 Class B / FCC Part15 B Harmonic Current Compliance to EN61000-3-2, Class A EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 129×98×38mm Packing 30PCS/CTN, 14.2KGS, 0.044CBM Cooling method Cooling by free air convection NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.        The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. 4.  Powerld offer accessories for Din-35 rail bar. Please contact sales staff for details. We always can deliver high-end quality industrial power supply products to our customers on time.Quality products,excellent service,we also welcome OEM and ODM industrial power supply orders.
  • VAT260UPXAA
    VAT260UPXAA
    Ø  Universal AC input (90~264Vac) Ø  With Active PFC, PF>0.95 Ø  Stand-by power consumption: 0.35W Ø  High Efficiency, long life and High reliability Ø  Output protections: OCP/OVP/SCP/OTP Ø  Wide operating ambient temperature (-30℃~65℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Fanless, quiet working Ø  PCB with conformal coating Ø  Low profile, 23mm Ø  3 years warranty    Ø  UL/CE/CCC/CB approved MODEL VAT260UP4.2AA VAT260UP5AA OUTPUT DC Output 4.2V 5V Rated Current 50A 50A CurrentRange    Note 1 0~50A 0~50A Ripple and Noise  Note 2 0~65℃ ≤250mV ≤300mV -30~0℃ ≤500mV ≤600mV Voltage Accuracy ±3% Set-up Time @25℃ ≤4S (220Vac input, 50A) Temperature Coefficient ±0.03%/℃ Overshoot ≤5.0% INPUT Voltage Range 90Vac~264Vac Rated input voltage range 100~240Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 90% @220Vac input, 50A ( 91% @220Vac, 60% load) AC Current (max.) <3.5A Inrush Current (Typical) <80A@220Vac     Cold start Power Factor @25℃ >0.95 (input 220Vac, 50A) Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA  (input 264Vac, 63Hz) Input Protection Under voltage protection point 55Vac~85Vac, shut down Under voltage recovery point 60Vac-90Vac, auto recovery, return difference≥5V Output PROTECTION Over Current ≥55A , auto recovery Over Voltage 4.6~6.5V, auto recovery 5.5~7V, auto recovery Over Temperature Test at40A Ambient temp. Protection when ambient temp. is over 65℃; auto recovery when ambient temp. is lower than 50℃ Housing temp. Protection when temp. of upper housing is over 85℃; auto recovery when it is less than 70℃ Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -30℃~65℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 4) Safety Standards IEC 62368-1, UL62368-1, EN62368-1 approved Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVdc/10mA. Isolation Resistance 10Mohms EMI Conduction & Radiation Compliance to EN55032  Class A EMSImmunity Compliance toEN61000-4-2,4,5,11; OTHERS MTBF >100000Hrs (25℃, Full load),MIL-217 Method 2 Components Stress Method Dimension (L*W*H) 165*55*23mm Packing 24pcs/CTN, 9.2Kgs/CTN Cooling method Power supply fixed on the aluminum plate of 450*450*3mm. NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttp://www.powerld.com.cn.
    A total of

    1

    pages
#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #