other
Search
Home Search
  • PS-45-SX power supply
    PS-45-SX
    Ø  Universal AC input/ Full range (90~264Vac) Ø  High Efficiency, long life and high reliability Ø  Output protections: SCP/OVP/ OLP/OPP Ø  Wide operating ambient temperature (-10℃~60℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  3 years warranty  MODEL PS-45-S12 PS-45-S24 PS-45-S48 OUTPUT DC Output 12V 24V 48V Rated Current 3.7A 1.9A 1A Ripple and Noise  Note 2 0~60℃ ≤120mV ≤120mV ≤120mV -10℃~0℃ ≤200mV ≤200mV ≤200mV Voltage ADJ. Range 11.4~13.2V 22.8~26.4V 45.6~52.8V Voltage Accuracy ±3.0% Line Regulation ±1.0% Load Regulation ±3.0% Set-up Time ≤0.8S @ 230Vac   full load Hold up Time ≥60mS @ 230Vac  full load Temperature Coefficient ±0.05%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange  Note 3 90Vac~264Vac FrequencyRange 47Hz-63Hz Efficiency ( Typical) 220Vac input ≥82% ≥85% ≥86% AC Current (max.) <1A(115VAC)  <0.6A(230VAC) Inrush Current (Typical) <20A@115Vac   <45A@230Vac     Cold start Leakage Current Input to Output:≤0.25mA ; Input to PG:≤3.5mA PROTECTION Over Load 3.9~6.2A 2.0~3.2A 1.1~1.56A Protection type: Hiccup mode, auto recovery Over Voltage 13.8~16.2V 27.6~32.4V 55.2~64.8V Protection type: Constant voltage, Auto recovery Over Power 46.8~75W 48~75W 53~75W Protection type: Hiccup mode, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -10℃~60℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -25℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 4) Safety Standards UL60950-1; EN60950-1:2006 Withstand Voltage Input-Output:3.0KVac/10mA ; Output-PG: 1.5KVac/10mA;Output-PG: 0.5KVdc/10mA Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022 Class B EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 101.6×51×28mm Packing 60PCS/CTN, 11KGS, 0.024CBM Cooling method Cooling by free air convection NOTE 1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.   We are Industrial power supply manufacturer with competitive price and good quality,which are widely recognized and trusted by users and can meet social needs.
  • LPD-150-X Power Supply
    LPD-150-X
    Ø  Universal AC input (90~264Vac) Ø  No load power consumption < 0.5W Ø  High efficiency, long life and high reliability Ø  Withstand 300Vac surge input for 5s Ø  Output protections: OLP/SCP/OVP/OPP Ø  Wide operating ambient temp (-30℃~70℃) Ø  Altitude up to 5000m Ø  All using 105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  1U low profile Ø  3 years warranty MODEL LPD-150-12 LPD-150-15 LPD-150-24 LPD-150-36 LPD-150-48 OUTPUT DC Output 12V 15V 24V 36V 48V Rated Current 12.5A 10A 6.25A 4.17A 3.125A Current Range     Note 1 0~12.5A 0~10A 0~6.25A 0~4.17A 0~3.125A Rated Power 150W 150W 150W 150W 150W Ripple and Noise @25C Note 2 150mV 150mV 200mV 200mV 200mV Voltage ADJ.  Range 10.8~13.2V 13.5~16.5V 21.6~26.4V 32.4~39.6V 43.2~52.8V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±0.5% Set-up Time ≤600ms/30ms (230Vac/115Vac input, Full load) Hold up Time ≥20mS(230Vac input, Full load)     Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT Voltage Range   90~264Vac  120-370VDC Frequency Range 47Hz~63Hz Efficiency ( Typical) @230Vac 84% 86% 88% 88% 89% AC Current (max.) ≤3A(115Vac)  /  ≤1.7A(230Vac) Inrush Current (Typical) ≤40A@220Vac   Cold start Leakage Current Input—output:<0.25mA ; Input—PG:<0.75mA   (Input 240Vac, 63Hz) PROTECTION Over current 120%~180% of rated current, Hiccup mode, auto recovery Over power 120%~180% of rated power, Hiccup mode, auto recovery Over voltage 120%~150% of rated output voltage, constant voltage, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -30℃~70℃;  20%~90%RH  No condensing Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards UL62368-1, IEC/EN62368-1 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance 100M ohms EMC Emission Compliance to EN55032 Class B EMC Immunity Compliance to EN61000-4-2,3,4,6,8,11 OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 159*97*30mm Packing 20pcs/CTN Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • LPD-350-X Power Supply
    LPD-350-X
    Ø  AC input selectable by switch (115Vac/230Vac) Ø  High efficiency, long life and high reliability Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temp (-25℃~70℃) Ø  Altitude up to 5000m Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  3 years warranty SPECIFICATION MODEL LPD-350-12 LPD-350-24 OUTPUT DC Output 12V 24V Rated Current 29.17A 14.58A Current Range     0~29.17A 0~14.58A Ripple and Noise  Note 2 0~70℃ ≤150mV ≤150mV -25℃ ≤300mV ≤300mV Voltage ADJ. Range 10.2~13.8V 21.6~28.8V Voltage Accuracy ±1.5% ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% ±0.5% Set-up Time ≤2.3S Full load Hold up Time ≥12mS/115Vac input, Full load; ≥16mS/230Vac input, Full load Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT VoltageRange   90Vac~132Vac/180Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency @230Vac input ≥85% ≥87% AC Current (max.) <6.8A/115Vac ; <3.4A/230Vac 2.5A Inrush Current ﹤60A@ 115Vac/230Vac  Cold start Leakage Current Input—output:<0.25mA    Input—PG:<2.0mA (Input 240Vac) PROTECTION Over Load 30.63~43.75A 15.31~21.88A Protection type: Hiccup mode, auto recovery Over Power 367.5~525W 367.5~525W Protection type: Hiccup mode, auto recovery Over voltage 13.8~16.2V 28.8~33.6V Protection type: Constant voltage, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards GB4943 / EN60950 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:2.0KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance 10M ohms EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 190*99*30mm Packing TBD Cooling method Cooling by forced air (Built-in DC fan) NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com
  • VAT-UP200U-X
    VAT-UP200U-X
    Ø  Universal AC input Ø  Built-in active PFC,PF>0.95 Ø  High efficiency, long life and high reliability Ø  Output protection: SCP/OLP/OVP/OPP Ø  Wide operating ambient temperature (-20~65℃) Ø  All using105℃long life electrolytic capacitor Ø  100% full load burn-in test Ø  3 years warranty MODEL VAT-UP200U-5 OUTPUT DC Output 5.0V Rated Current 40A CurrentRange    Note 1 0~40A Peak load 45A (50mS, 220Vac input) Ripple and Noise  Note 2 0~65℃ ≤250mV -20℃ ≤300mV Voltage ADJ. Range / Voltage Accuracy ±4.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2S (220VAC input, 40A) Hold up Time ≥5mS (220Vac input, 32A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac FrequencyRange 47Hz--63Hz Power Factor(Typical) PF>0.95/230VAC   full load Efficiency ( Typical) ≥89%(220VAC, 40A)    ≥87%(110VAC, 30A) AC Current (max.) <2A Inrush Current (Typical) <60A@230Vac Cold start Leakage Current Input—output:<0.25mA    Input—PG:<3.5Ma (264Vac, 63Hz) PROTECTION Over Load 44~65A, Hiccup mode, auto recovery Over power 220~320W, hiccup mode, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -20℃~65℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing Vibration 10 ~ 500Hz,2G10min./1cycle, period for 60min. each along X,Y, Z axes Withstand Voltage Primary-Secondary: 3.0KVac; ≤10mA .Primary-PG: 1.5KVac; ≤10mA. Secondary-PG: 0.5KVDC; ≤10mA. Isolation Resistance 10Mohms SAFETY&EMC (Note 3) EMI Conduction & Radiation Compliance to EN55022, EN55024, FCC PART 15  CLASS B Harmonic Current Compliance to EN61000-3-2, Class D EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 100,000Hrs (25℃, Full load) Dimension (L*W*H) 210×31.5×30mm Packing 49PCS/CTN, 15KGS, 0.04CBM Cooling method Cooling by air NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttp://www.powerld.com.cn.
  • VAT-HP260-X-C
    VAT-HP260-X-C
    Ø  High voltage input (176~264Vac) Ø  With Active PFC, PF>0.95 Ø  Surge 300Vac for 60S Ø  High Efficiency, long life and High reliability Ø  Output protections: OCP/SCP/OPP/OTP Ø  Wide operating ambient temperature (-40℃~50℃) Ø  Operating altitude up to5000m Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Fanless, quiet working Ø  PCB with conformal coating Ø  Low profile, 30mm        Ø  3 years warranty MODEL VAT-HP260-5.2-C OUTPUT DC Output 5.2V Rated Current 40A Current Range     Note 1 0~50A Peak load 55A Ripple and Noise  Note 2 0~50℃ ≤150mV -40~0℃ ≤400mV Voltage Accuracy@-40~50C ±3% Line Regulation ±0.5% Load Regulation ±2% Set-up Time @25℃ ≤2S (220Vac input,40A) Hold up Time ≥5mS (220Vac input,32A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <±5% INPUT Voltage Range   Note 3 176~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) 92%  (220Vac input,40A) AC Current (max.) <3.5A Inrush Current (Typical) <60A@220Vac      Cold start Power Factor @25℃ >0.95  (input 220Vac,40A) Stand by power consumption <4W Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA   (input 264Vac, 63Hz) PROTECTION Over Current 55~80A , hiccup mode, auto recovery Over Power 286~416W, hiccup mode, auto recovery Over Temperature 115℃+5℃(detect on temperature protector);shut down, auto recovery after ambient temperature goes down to 50℃(temperature protector goes down to 85℃+15℃) Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~50℃;  20%~90%RH  No condensing(refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC   (Note 3) Safety Standards GB4943 / EN60950 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 10M ohms EMI Conduction&Radiation Compliance to EN55022, EN55024, FCC PART 15   CLASS B Harmonic current Compliance to EN61000-3-2, Class D EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) >200000h (25℃, Full load) Dimension  (L*W*H) 133*55*30mm Packing 49PCS/CTN, 15KGS, 0.04CBM Cooling method Cooling by free air convection NOTE 1.   All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.   Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.