VAT-UP400S-X-60L-A
l AC input: 90-264Vac l Built-in Active PFC, PF>0.93 l Output protections: OLP/SCP/OTP/OPP l Wide operating ambient temperature (-40℃~80℃) l No fan suitable for quiet environment l 100% full load burn-in test l Long life and high reliability l High efficiency up to 90% l Conformal coating l Low profile, 30mm l 3 years warranty MODEL VAT-UP400S-5-60L-A OUTPUT DC Output 5V Output Pre set voltage 5.0-5.10V (220Vac input, load 0A) Rated Current 80A CurrentRange Note 1 0~80A Peak load 90A, last 50mS @ 220Vac Ripple and Noise 25~80℃ ≤150mV Voltage Adj. Range 4.15~5.10V Voltage Accuracy ±2.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2.5S (110Vac input, Full load), ≤1S (220Vac input, Full load) Hold up Time ≥10mS(220Vac input, 80% load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5% INPUT VoltageRange 90Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 90%(220Vac input ,full load) AC Current (max.) <5A Inrush Current (Typical) <80A@220Vac Cold start Power factor >0.93(220Vac input ,full load); >0.95/(110Vac input ,full load) PROTECTION Over Power 425W~550W, Hiccup mode, auto recovery Over Current 85A~110A, Hiccup mode, auto recovery Shorted Circuit Long-term mode, auto recovery Over Temperature 105℃+5℃(detect on Q1/D1 batten);shut down, auto recovery after the temperature goes down ENVIRONMENT Operating amb. Temp. & Hum. -40℃~80℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards GB4943-2001; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Leakage Current Input—output: ≤0.25mA Input—PG: ≤3.5mA (264Vac input,63Hz) Isolation Resistance 10Mohms EMI Conduction & Radiation EN55022, EN55024, FCC Part 15, Class B Harmonic Current EN61000-3-2 CLASS D EMSImmunity EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) >200,000Hrs,full load Dimension (L*W*H) 235*60*30mm Packing 18pcs/CTN Cooling method Free air flow (Fixed to aluminum heatshink of customer’s system) NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 100uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. We cannot guarantee that the final equipment will meet EMC directives, Final product manufactures must be re-confirm that their product meets EMC directives. We provide high-quality LED power supplies for indoor and outdoor, and a variety of specifications and models of LED power supplies are optional, suitable for specific lighting applications in multiple fields.