other
Search
Home Search
  • VAT-UP200S-X-P
    VAT-UP200S-X-P
    Ø  Universal AC input (90~264Vac) Ø  With Active PFC, PF>0.95 Ø  Surge 300Vac for 60S Ø  High Efficiency, long life and High reliability Ø  Output protections: OLP/OVP/SCP/OTP/OPP Ø  1+1 parallel function, current sharing Ø  Wide operating ambient temperature (-40℃~65℃) Ø  Operating altitude up to5000m Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Fanless, quiet working Ø  PCB with conformal coating        Ø  3 years warranty MODEL VAT-UP200S-4.6-P VAT-UP200S-5-P OUTPUT DC Output 4.6V 5V Rated Current 40A 40A CurrentRange    Note 1 0~40A 0~40A Peak load 50A(50mS, 220Vac input) 48A(50mS, 220Vac input) Ripple and Noise  Note 2 0~65℃ ≤150mV ≤150mV Voltage Accuracy@-20~65C ±3% ±3% Line Regulation/ ±0.5% Load Regulation ±2% Set-up Time @25℃ ≤2S (220Vac input,40A) Hold up Time ≥5mS (220Vac input,32A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% Parallel (current sharing) Current-unbalance< 10% (single PS drive40Aload, the voltage of current share bus is 5~6V) INPUT VoltageRange  Note 3 90Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 110Vac 87% 89% 220Vac 88% 90% AC Current (max.) <3.5A Inrush Current (Typical) <15A@220Vac     Cold start Power Factor @25℃ >0.95 (input 220Vac,40A) Stand by power consumption <4W (input 220Vac) Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA  (input 264Vac, 63Hz) PROTECTION Over Load 44~65A, hiccup mode, auto recovery 45~55A, hiccup mode, auto recovery Over Power 193~299W, hiccup mode, auto recovery 225~275W, hiccup mode, auto recovery Over Voltage 5.1~7V, hiccup mode, auto recovery 5.2~6.5V, hiccup mode, auto recovery Over Temperature 105℃+10℃(detect on temperature controller of PFC);shut down, auto recovery after the temperature goes down to75℃ Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~65℃; 20%~90%RH No condensing(refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 4) Safety Standards UL60950-1 2ndEd; IEC 60950-1:2005(2ndEd) ;EN60950-1:2006 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 10Mohms EMI Conduction&Radiation Compliance to EN55022, EN55024, FCC PART 15 CLASS B Harmonic current Compliance toEN61000-3-2CLASSD EMSImmunity Compliance toEN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) >200000h (25℃, Full load) Dimension (L*W*H) 210*50*29mm Packing 28PCS/CTN, 0.04CBM Power Good Signal Working properly: 3.3V Working abnormally: <0.7V Reverse voltage start 4.6V output When output reverse voltage is 5~5.1V, PS starts normally. 5V output When output reverse voltage is 5~10V, PS starts normally. Cooling method Cooling by free air convection NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and 25℃of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttp://www.powerld.com.cn.
  • VAT-HP260-X-C
    VAT-HP260-X-C
    Ø  High voltage input (176~264Vac) Ø  With Active PFC, PF>0.95 Ø  Surge 300Vac for 60S Ø  High Efficiency, long life and High reliability Ø  Output protections: OCP/SCP/OPP/OTP Ø  Wide operating ambient temperature (-40℃~50℃) Ø  Operating altitude up to5000m Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Fanless, quiet working Ø  PCB with conformal coating Ø  Low profile, 30mm        Ø  3 years warranty MODEL VAT-HP260-5.2-C OUTPUT DC Output 5.2V Rated Current 40A Current Range     Note 1 0~50A Peak load 55A Ripple and Noise  Note 2 0~50℃ ≤150mV -40~0℃ ≤400mV Voltage Accuracy@-40~50C ±3% Line Regulation ±0.5% Load Regulation ±2% Set-up Time @25℃ ≤2S (220Vac input,40A) Hold up Time ≥5mS (220Vac input,32A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <±5% INPUT Voltage Range   Note 3 176~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) 92%  (220Vac input,40A) AC Current (max.) <3.5A Inrush Current (Typical) <60A@220Vac      Cold start Power Factor @25℃ >0.95  (input 220Vac,40A) Stand by power consumption <4W Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA   (input 264Vac, 63Hz) PROTECTION Over Current 55~80A , hiccup mode, auto recovery Over Power 286~416W, hiccup mode, auto recovery Over Temperature 115℃+5℃(detect on temperature protector);shut down, auto recovery after ambient temperature goes down to 50℃(temperature protector goes down to 85℃+15℃) Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~50℃;  20%~90%RH  No condensing(refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC   (Note 3) Safety Standards GB4943 / EN60950 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 10M ohms EMI Conduction&Radiation Compliance to EN55022, EN55024, FCC PART 15   CLASS B Harmonic current Compliance to EN61000-3-2, Class D EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) >200000h (25℃, Full load) Dimension  (L*W*H) 133*55*30mm Packing 49PCS/CTN, 15KGS, 0.04CBM Cooling method Cooling by free air convection NOTE 1.   All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.   Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • VAT-H300S-X-60L
    VAT-H300S-X-60L
    Ø  High AC input (180-264Vac) Ø  Long life and High reliability Ø  High efficiency up to 89% Ø  Output protections: SCP/OPP/OLP Ø  Wide operating ambient temperature (-40℃~65℃) Ø  @-40C, PS can work normally Ø  Altitude up to 5000m Ø  PCB with conformal coating Ø  100% full load burn-in test Ø  2 years warranty MODEL VAT-H300S-5-60L OUTPUT DC Output 5V Rated Current 60A Current Range     Note 1 0~60A Peak load 65A, last 100mS /220Vac Ripple and Noise  Note 2 25~65℃ ≤150mV 0~25℃ ≤200mV Voltage ADJ.  Range 4.15~5.08V Voltage Accuracy ±2.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2S (220VAC input, Full load) Hold up Time ≥10mS (220VAC input, 80% load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   180Vac~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) 89%(220Vac input, full load) AC Current (max.) <3.5A Inrush Current (Typical) <100A@220Vac      Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Power 315~450W, hiccup mode, auto recovery Over Current 63~90A, hiccup mode, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~65℃;  20%~90%RH  No condensing Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards GB4943/ EN60950 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance 10M ohms EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11 OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 208*60*30mm Packing TBD Cooling method Free air convection NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.  The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
  • CMG-H150D5G+12-M
    CMG-H150D5G+12-M
    Features: Ø  High AC voltage input (176~264Vac) Ø  High Efficiency, and High reliability Ø  Output protections: SCP/OVP/OPP/OLP Ø  Wide operating ambient temperature (-25℃~65℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  2 years warranty              Ø  Isolated Dual Outputs MODEL CMG-H150D5G+12-M OUTPUT DC Output V1 V2 5V 12V Rated Current 10A 8A 1~10A 0.8~8A Ripple and Noise Note2 0~65℃ ≤50mV ≤120mV -25℃ ≤100mV ≤240mV Voltage ADJ.  Range 4.6~5.4V / Voltage Accuracy ±1.0% ±10.0% Line Regulation ±0.5% ±1.0% Load Regulation ±3.0% ±10.0% Set-up Time <1.5S (220Vac input, Full load) Hold up Time >20mS(220Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   176Vac~264Vac Frequency Range 47Hz--63Hz Efficiency ( Typical) 75% AC Current (max.) <1.9A Inrush Current (Typical) <50A@220Vac      Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Power 175~225W, Hiccup mode, auto recovery Over Current V1: 11~22A, hiccup mode, auto recovery Over Voltage V1: 5.25~7.5V, Hiccup mode, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~65℃;  20%~90%RH  No condensing Storage Temp. & Hum. -30℃~85℃;  10%~95%RH  No condensing SAFETY &EMC   (Note 5) Safety Standards GB4943/EN60950 Withstand Voltage Primary-Secondary: 3.0KVac/10mA ; Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA.  Output V1—V2: 0.5KVDC/10mA. Test time:1 min Isolation Resistance 10M ohms EMI Conduction&Radiation Compliance to EN55022 Class B Harmonic Current Compliance to EN61000-3-2, Class A EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 199×99×38mm Packing 20PCS/CTN, 15KGS, 0.04CBM Cooling method Cooling by free air convection NOTE   1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.  The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • CMG-H150D24G+12-M
    CMG-H150D24G+12-M
    Ø  High voltage input, 176~264Vac Ø  High Efficiency, long life and High reliability Ø  Output protections: SCP/OVP/OLP/OPP Ø  Wide operating ambient temperature (-25℃~65℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  2 years warranty             Ø  Isolated Dual Outputs MODEL CMG-H150D24G+12-M OUTPUT DC Output V1 24V V2 12V Rated Current V1 6A V2 5A      Current Range  Note 3 V1 0.5~5.0A(5.0Ais recommended) V2 0.3~3.0A(3.0Ais recommended) Ripple and Noise Note4 0~65℃ V1 240mV V2 120mV Ripple and Noise -25~0℃ V1 480mV V2 240mV Voltage ADJ.  Range 21.6~26.4V Voltage Accuracy V1 ±1.0% V2 ±10.0% Line Regulation V1 ±0.5% V2 ±1.0% Load Regulation V1 ±3.0% V2 ±10.0% Set-up Time <1.5S (220Vac input, V1 @ 5A, V2 @ 3.0A) Hold up Time >20mS(220Vac input, V1 @ 5A, V2 @ 3.0A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   176Vac~264Vac Frequency Range 47Hz--63Hz Efficiency ( Typical) ≥80% (220Vac input, V1 @5A, V2 @3.0A) AC Current (max.) <1.9A Inrush Current (Typical) <50A@220Vac      Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Power 157~225W, Hiccup mode, auto recovery Over Current V1: 5.5~8.0A, Hiccup mode, auto recovery Over Voltage V1: 25.2~36V, Hiccup mode, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~65℃;  20%~90%RH  No condensing Storage Temp. & Hum. -30℃~85℃;  10%~95%RH  No condensing SAFETY &EMC   (Note 5) Safety Standards GB4943/ EN60950 Withstand Voltage Primary-Secondary:3.0KVac /10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA.  Output V1—V2: 0.5KVDC/10mA. Test time:1 min Isolation Resistance 10M ohms EMI Conduction&Radiation Compliance to EN55022, CLASS B Harmonic Current Compliance to EN61000-3-2,CLASS A EMS Immunity Compliance to EN61000-4-2,4,5,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 199×99×38mm Packing 20PCS/CTN, 15KGS, 0.04cbm Cooling method Cooling by free air convection NOTE   1.     Total output power can’t exceed 150W, Label is marked by the Max current. Recommend the loading is 24V/5A,12V/3.0A.  2.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 3.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 4.        The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
  • GS-25-12II
    GS-25-12II
    Ø  Universal AC input range(90~264Vac) Ø  Miniature size, high power density, high efficiency, long life and high reliability Ø  Output protections: OLP/OPP/SCP Ø  Wide operating ambient temp (-10℃~45℃) Ø  Altitude up to5000m Ø  100% full load burn-in test Ø  1 year warranty     SPECIFICATION                                              MODEL GS-25-12II OUTPUT DC Output 12V Rated Current 2A Current Range      0~2A Ripple and Noise  Note 2 0~45℃ <100mV -10~0℃ <120mV Voltage ADJ.  Range 10.8~13.2V Voltage Accuracy ±3.0% Line Regulation ±0.25% Load Regulation ±3.0% Set-up Time ≤1.0S (220Vac input, Full load) Hold up Time >20mS(220Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   90Vac~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) 220Vac,full load ≥78% AC Current (max.) <0.8A 2.5A 0.7A 0.7A 0.7A Inrush Current (Typical) <50A@220Vac      Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Load 2.1~3A, hiccup mode, auto recovery Over power 25.2~36W, hiccup mode, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -10℃~45℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -25℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards GB4943/EN60950 Withstand Voltage Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance 100M ohms EMC Emission Compliance to EN55022 Class B EMC Immunity Compliance to EN61000-4-2,4,5,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 115×49×29mm Packing 72PCS/CTN, 16.0KGS, 0.04CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn. We always can deliver high-end quality industrial power supply to our customers on time.Welcome you to contact us for more power supply information and look forward to working with you!
  • GS-35-12 Power Supply
    GS-35-12
    Ø  Universal AC input range(90~264Vac) Ø  High efficiency, long life and high reliability Ø  Output protections: OLP/SCP/OPP Ø  Wide operating ambient temp (0℃~50℃) Ø  Altitude up to5000m Ø  100% full load burn-in test Ø  1 years warranty SPECIFICATION                                                           MODEL            GS-35-12             DC Output         12V         Rated Current          3A         Current Range     Note 1          0~3A         Ripple and Noise          Note 2          0~50℃         <120mV         Voltage ADJ.  Range         11.4V-12.6V         Voltage Accuracy         ±1.0%         Line Regulation           ±0.5%         Load Regulation         ±0.5%         Set-up Time         ≤1S (230Vac input, Full load) ; ≤2S (115Vac input, Full load)         Hold up Time         ≥20mS(230Vac input, Full load) ; ≥10mS(115Vac input, Full load)         Temperature Coefficient         ±0.03%/℃         Overshoot and Undershoot         <5.0%         INPUT         Voltage Range           90Vac~264Vac         Frequency Range         47Hz~63Hz         Efficiency ( Typical)     ≥82%         AC Current (max.)      <1 A         2.5A         Inrush Current (Typical)     ﹤45A@230Vac max   Cold start         Leakage Current         Input—output:<0.25mA     Input—PG:<3.5mA         PROTECTION         Over Load         3.3A~4.5A, Hiccup mode, auto recovery         Over power         110%~150% of rated power, hiccup mode, auto recovery         Shorted Circuit         Long-term mode, auto recovery         ENVIRONMENT         Operating amb. Temp. & Hum.         0℃~50℃;  20%~90%RH  No condensing         Storage Temp. & Hum. -       40℃~85℃;  10%~95%RH  No condensing         SAFETY &EMC   Note 3         Safety Standards         EN60950/UL60950         Withstand Voltage         Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-                            PG:0.5KVDC;≤10mA.         Isolation Resistance     ≥100M ohms         EMC Emission         Compliance to EN55022 Class B         EMC Immunity         Compliance to EN61000-4-2,3,4,5,6,8,11;         OTHERS         MTBF (MIL-HDBK-217F)         More than 200,000Hrs (25℃, Full load)         Dimension  (L*W*H)           98×81×35mm         Packing         45PCS/CTN, 17.2KGS, 0.04CBM         Cooling method         Cooling by free air convection          NOTE         1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature.         2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor.         3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn. We alwa...
  • GS-60-12Power Supply
    GS-60-12
    MODEL GS-60-12 ABS-75-12 ABS-75-24 ABS-75-48 OUTPUT DC Output 12V 12V 24V 48 Rated Current 5A 6A 3.2A 1.62A Current Range     Note 1 0~5A 0~6A 0~3.2A 0~1.62A Ripple and Noise  Note 2 0~50℃ <120mV Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±0.5% Set-up Time ≤1S /230Vac input, Full load) Hold up Time ≥20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   90Vac~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) ≥82% ≥84% ≥86.5% ≥88% AC Current (max.) <1.3 A 2.5A Inrush Current (Typical) ﹤45A@230Vac   Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Load 5.5~7.5A, hiccup mode, auto recovery Over power 110%~150% of rated power, hiccup mode, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. 0℃~50℃;  20%~90%RH  No condensing Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards EN60950 Withstand Voltage Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100M ohms EMC Emission / EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 99*82*35mm Packing 45PCS/CTN, 17.2KGS, 0.04CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. We always can deliver high-end quality industrial power supply to our customers on time.Welcome you to contact us for more power supply information and look forward to working with you!
    A total of

    10

    pages
#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #