other
Search
Home Search
  • DG-480-X Din rail power supply
    DG-480-X
    Ø  Universal AC input range(85~264Vac) Ø  Support 1+1 or N+1 redundant system(suggest to use redundancy modules.) Ø  Built-in active PFC,PF>0.95 Ø  High efficiency up to 94% Ø  Built-in current sharing function Ø  Built-in current limiting circuit Ø  Output protections: OVP/OLP/SCP/OTP Ø  Wide operating ambient temp (-25℃~70℃) Ø  150%(720W) peak load capacity Ø  Easy Fuse Tripping due to High Overload Current Ø  Built-in DC OK relay contact Ø  Can be installed on TS-35/7.5 or TS-35/15 Ø  100% full load burn-in test Ø  Suitable for critical applications Ø  Ultra-slim,70mm width Ø  Free air convection Ø  3 years warranty SPECIFICATION MODEL DG-480-24 ABS-75-12 DG-480-48 OUTPUT DC Output 24V 12V 48V Rated Current 20A 6A 10A CurrentRange    Note 1 0~20A 0~6A 0~10A Ripple and Noise  Note 2 0~70℃ ≤240mV ≤480mV -25℃ ≤480mV ≤480mV Voltage ADJ. Range 24~28V 48~56V Voltage Accuracy ±3.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <3S@230Vac  Hold up Time ≥20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   85Vac~264Vac, 130Vdc-350Vdc FrequencyRange 47Hz~63Hz Power Factor (typical) 0.99/110Vac    0.95/230Vac Efficiency ( Typical) 93.8% ≥84% 93.8% ≥88% AC Current (max.) <7.0 A/100Vac       <3.5A/230Vac Inrush Current (Typical) <20A/110Vac     <40A/230Vac  Cold start Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA PROTECTION Over Load 110%~150% of rated current, Constant current limiting for some time(150% of rated current, last 3S) then PS stop working for 7S,after 7S,if the load <=rated current, PS will work normally, auto recovery Over voltage 28.8~33V, constant voltage, Auto recovery 58~63V, constant voltage, Auto recovery Over temperature 115±5℃, detect on temperature controller; shut down O/P, auto recovery after temperature goes down. Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 5%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards meet UL508, UL60950, EN60950 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG: 2.5KVac/10mA. Secondary-PG:0.5KVac/20mA. Output-DC OK: 0.5KVac/1mA Isolation Resistance 10Mohms EMC Emission Compliance to EN55022, EN55024, FCC PART 15 Class B Harmonic Current Compliance to EN61000-3-2, CLASS A EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 300,000Hrs (25℃, Full load) Dimension (L*W*H) 70*124*127mm Packing 10pcs/CTN, 13Kgs/CTN, 0.04cbm Cooling method Cooling by free air convection Additional function Power boost 150% of rated current Parallel function support DC-OK V On: when output voltage is up to 90% of rated output voltage V Off: when output voltage is down to 80% of rated output voltage DC-OK relay contact rating Max 30V/1Aor 60V/0.3Aor 30Vac/0.3AResistive load NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com. We have a complete DIN rail power supply product catalog, providing reliable quality DIN rail power supply and affordable prices, fast delivery, customizable, please leave a message for consultation.
  • DG-U75SX Din rail power supply
    DG-U75SX
    Ø  Universal AC input range(90~264Vac) Ø  Long life, high reliability and high efficiency Ø  Built-in current limiting circuit Ø  Output protections: OVP/OLP/SCP/OTP Ø  Wide operating ambient temp (-20℃~70℃) Ø  Can be installed on TS-35/7.5 or TS-35/15 Ø  100% full load burn-in test Ø  Suitable for critical applications Ø  Ultra-slim,45mm width Ø  3 years warranty SPECIFICATION MODEL DG-U75S12 DG-U75S24 OUTPUT DC Output 12V 24V Rated Current 6.25A 3.2A CurrentRange    Note 1 0~6.25A 0~3.2A Ripple and Noise  Note 2 0~70℃ ≤120mV ≤120mV -20℃ ≤240mV ≤240mV Voltage ADJ. Range 12~14V 24~28V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <1.5S@230Vac ; <3.0mS@115Vac Hold up Time ≥10mS@115Vac;  ≥20mS@230Vac    Full load Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac, 127Vdc-370Vdc FrequencyRange 47Hz~63Hz Efficiency ( Typical) 82% 87% AC Current (max.) <2.0A/115VAC ; <1.0A/230VAC Inrush Current (Typical) 20A/115Vac  ;  35A/230Vac  Cold start Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA (264Vac input, 63Hz) PROTECTION Over Load 7.0~9.5A 5.25~6.5A Protection type: Constant current Over voltage 15~18V 29~33V Protection type: Shut down, re-power on. Over temperature 100±5℃, detect on heat sink of power transistor; shut down O/P, re-power on. Short Circuit Long-term mode, auto recovery Operating amb. Temp. & Hum. -20℃~70℃; 20%~90%RH No condensing (pls refer to derating curve) ENVIRONMENT Storage Temp. & Hum. -40℃~85℃; 5%~95%RH No condensing Safety Standards UL508, UL60950, EN60950 SAFETY &EMC Note 3 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG: 2.0KVac/10mA. Secondary-PG: 0.5KVac/10mA. Isolation Resistance 10Mohms EMC Emission Compliance to EN55022, EN55024, FCC PART 15 Class B Harmonic Current Compliance to EN61000-3-2, CLASS A EMC Immunity Compliance to EN61000-4-2,3,4,5,6,11; heavy industry level MTBF (MIL-HDBK-217F) More than 500,000Hrs (25℃, Full load) OTHERS Dimension (L*W*H) 124*119*45mm Packing 24pcs/CTN,15.0Kg, 0.04cbm Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com. We have a complete DIN rail power supply product catalog, providing reliable quality DIN rail power supply and affordable prices, fast delivery, customizable, please leave a message for consultation.
  • DG-U120SX Din rail power supply
    DG-U120SX
    Ø  Universal AC input range(90~264Vac) Ø  High efficiency up to 89% Ø  Built-in current limiting circuit Ø  Output protections: OVP/OLP/SCP/OTP Ø  Wide operating ambient temp (-20℃~70℃) Ø  Built-in DC OK function Ø  Can be installed on TS-35/7.5 or TS-35/15 Ø  100% full load burn-in test Ø  Suitable for critical applications Ø  Operating altitude up to6000m Ø  PCB with conformal coating Ø  Ultra-slim,45mm width Ø  3 years warranty SPECIFICATION                                               MODEL DG-U120S12 DG-U120S24 DG-U120S48 OUTPUT DC Output 12V 24V 48V Rated Current 10A 5A 2.5A CurrentRange    Note 1 0~10A 0~5A 0~2.5A Ripple and Noise  Note 2 0~70℃ ≤120mV ≤120mV ≤240mV -20℃~0 ≤240mV ≤240mV ≤480mV Voltage ADJ. Range 12~14V 24~28V 48~56V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <1.2S@230Vac ; <3.0mS@115Vac Hold up Time ≥10mS@115Vac; ≥20mS@230Vac    Full load Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac, 127Vdc-370Vdc FrequencyRange 47Hz~63Hz Efficiency ( Typical) 85% 88% 89% AC Current (max.) <2.7 A/115VAC ; <1.35A/230VAC Inrush Current (Typical) 20A/115Vac  ;  35A/230Vac  Cold start Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA (264Vac input, 63Hz) PROTECTION Over Load 10.5~13A 5.25~6.5A 2.75~3.25A Protection type: Constant current Over voltage 15~18V 29~33V 58~63V Protection type: Shut down, re-power on. Over temperature 100±5℃, detect on heat sink of power transistor; shut down O/P, re-power on. Short Circuit Long-term mode, auto recovery Operating amb. Temp. & Hum. -20℃~70℃; 20%~90%RH No condensing (pls refer to derating curve) ENVIRONMENT Storage Temp. & Hum. -40℃~85℃; 5%~95%RH No condensing Safety Standards UL508, UL60950, EN60950 SAFETY &EMC Note 3 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG: 1.5KVac/10mA. Secondary-PG: 0.5KVac/10mA. Isolation Resistance 10Mohms EMC Emission Compliance to EN55022, EN55024, FCC PART 15 Class B Harmonic Current Compliance to EN61000-3-2, CLASS A EMC Immunity Compliance to EN61000-4-2,3,4,5,6,11; heavy industry level MTBF (MIL-HDBK-217F) More than 500,000Hrs (25℃, Full load) OTHERS Dimension (L*W*H) 124*119*45mm Packing 24pcs/CTN,15.0Kg, 0.04cbm Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com. DIN rail power supply is a kind of switching power supply, which can convert unstable input voltage into stable output voltage. We can meet all industry standards of DIN rail power supply. Learn more, follow us, and leave us a message.
  • CMG-H150DXG+X power supply
    CMG-H150DXG+X
    Ø  High Efficiency, and High reliability Ø  Output protections: SCP/OVP/OPP/OLP Ø  Wide operating ambient temperature (-10℃~50℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  2 years warranty      Ø  Isolated Dual Outputs SPECIFICATION MODEL CMG-H150D12G+24 CMG-H150D24G+12 OUTPUT DC Output V1 12.0V 24.0V V2 24.0V 12.0V Rated Current V1 5A 6A       Note 2 V2 6A      Note 1 5A CurrentRange Note 3 V1 0.5~5.0A 0~6.0A V2 0.6~6.0A 0~5.0A Ripple and NoiseNote4 0~65℃ V1 120mV 240mV V2 240mV 120mV Ripple and Noise -25~0℃ V1 240mV 480mV V2 480mV 240mV Voltage ADJ. Range 11.4V~12.6V 22.8V~25.0V Voltage Accuracy V1 ±1.0% ±1.0% V2 ±10.0% ±10.0% Line Regulation V1 ±0.5% V2 ±1.0% Load Regulation V1 ±3.0% V2 ±10.0% Set-up Time <1.0S (230Vac input, Full load) Hold up Time >20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   176Vac~264Vac FrequencyRange 47Hz--63Hz Efficiency ( Typical) 80% 80% AC Current (max.) 2.0A/176VAC Inrush Current (Typical) 50A@220Vac     Cold start Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA PROTECTION Over Power 105%~150% of rated output current, auto recovery Over Current V1 110%~220%    Auto recovery 110%~150%    Auto recovery Over Voltage V1: 110%~150% of rated output voltage, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -10℃~50℃; 20%~90%RH No condensing Storage Temp. & Hum. -30℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 5) Safety Standards GB4943-2001; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA. Secondary-PG:0.5KVDC;≤10mA. Output V1—V2: 0.5KVDC;≤10mA. Test time:1 min Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022(CISPR22)ClassB Harmonic Current Compliance to EN61000-3-2,17625.1-2003 EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA OTHERS MTBF (MIL-HDBK-217F) More than 100,000Hrs (25℃, Full load) Dimension (L*W*H) 199×98×40mm Packing 0.75Kg/pcs,20PCS/CTN, 15KGS. Cooling method Cooling by free air convection NOTE 1.    CMG-H150D12G+24 Total output power can’t exceed 150W, Label is marked by the Max current. Recommend the loading is 12V/5A,24V/3.75A.   2.    CMG-H150D24G+12Total output power can’t exceed 150W, Label is marked by the Max current. Recommend the loading is 24V/5A,12V/3.0A.  3.    All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 4.    Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 5.    The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. Powerld enterprises is specialized in switching power supply since 1991, obtained ISO9001 certificate in 2002, ISO14001 certificate in 2006.As a professional switching power supply manufacturer,Powerld can supply a broad range of power supply,we can not only supply our customers with high quality products,but also our best service and fast delivery time.
  • VAT-UP400S-X-60L-P
    VAT-UP400S-X-60L-P
    l  AC input: 90VAC ~ 264VAC l  Built-in Active PFC, PF>0.95  l  High efficiency, long life and high reliability l  Output protections: OLP/SCP/OTP l  Wide operating ambient temperature  (-40℃~80℃) l  No fan suitable for quiet environment l  100% full load burn-in test l  1+1 and redundancy, current sharing function l  Conformal coating l  3 years warranty MODEL VAT-UP400S-5-60L-P OUTPUT DC Output 5V Output Pre set voltage 5.0-5.10V (220Vac input, load 0A) Rated Current 80A  ( PSU fixed on heat sink of square > 400*400*2mm aluminum plate) CurrentRange    Note 1 0~80A Ripple and Noise 25~80℃ ≤150mV 0-25C ≤200mV Voltage Adj. Range 4.15~5.10V Voltage Accuracy ±2.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2.5S (110VAC input, Full load) Hold up Time ≥8mS(220Vac input, 80% load) Temperature Coefficient ±0.03%/℃ Current sharing unbalance <10% (Current sharing bus voltage is 2.9-4V, single PS at 80A load) ) Overshoot and Undershoot <5% INPUT VoltageRange 90Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 88%(220Vac input ,full load) AC Current (max.) <5A Inrush Current (Typical) <80A@220Vac     Cold start Power factor >0.93(220Vac input ,full load);  >0.95/(110Vac input ,full load) PROTECTION Over Power 425W~550W, Hiccup, auto recovery Over Current 85A~110A, Hiccup, auto recovery Shorted Circuit Long-term mode, auto recovery Over Temperature 105℃+5℃(detect on Q1/D1 batten);shut down, auto recovery after the temperature goes down ENVIRONMENT Operating amb. Temp. & Hum. -40℃~80℃; 20%~90%RH No condensing  (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Leakage Current Input—output: ≤0.25mA    Input—PG: ≤3.5mA (264Vac input, 63Hz) Isolation Resistance 10Mohms EMI Conduction & Radiation Compliance to EN55022, EN55024, FCC PART 15  CLASS B Harmonic Current Compliance to EN61000-3-2 CLASS D EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 250*60*30mm Packing TBD Cooling method Free air convection PG SIGNAL Power indicator terminal voltage 1.       Power supply is normal, the signal voltage: 3.0V ~ 3.5V (current 0~1mA) 2.       Power supply is abnormal, the signal voltage: 0V ~ 0.7V, (pull-up resistor is greater than 10kΩ) 3.       Control card to detect POWER GOOD signal port, in order to prevent interference misoperation, Recommended MCU or FPGA detection port to add the 0.01uF decoupling capacitor. NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 100uF parallel capacitor. 3. he SPS is considered a component which will be installed into final equipment. We cannot guarantee that the final equipment will meet EMC directives, Final product manufactures must be re-confirm that their product meets EMC directives.
  • VAT260UPXAA
    VAT260UPXAA
    Ø  Universal AC input (90~264Vac) Ø  With Active PFC, PF>0.95 Ø  Stand-by power consumption: 0.35W Ø  High Efficiency, long life and High reliability Ø  Output protections: OCP/OVP/SCP/OTP Ø  Wide operating ambient temperature (-30℃~65℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Fanless, quiet working Ø  PCB with conformal coating Ø  Low profile, 23mm Ø  3 years warranty    Ø  UL/CE/CCC/CB approved MODEL VAT260UP4.2AA VAT260UP5AA OUTPUT DC Output 4.2V 5V Rated Current 50A 50A CurrentRange    Note 1 0~50A 0~50A Ripple and Noise  Note 2 0~65℃ ≤250mV ≤300mV -30~0℃ ≤500mV ≤600mV Voltage Accuracy ±3% Set-up Time @25℃ ≤4S (220Vac input, 50A) Temperature Coefficient ±0.03%/℃ Overshoot ≤5.0% INPUT Voltage Range 90Vac~264Vac Rated input voltage range 100~240Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 90% @220Vac input, 50A ( 91% @220Vac, 60% load) AC Current (max.) <3.5A Inrush Current (Typical) <80A@220Vac     Cold start Power Factor @25℃ >0.95 (input 220Vac, 50A) Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA  (input 264Vac, 63Hz) Input Protection Under voltage protection point 55Vac~85Vac, shut down Under voltage recovery point 60Vac-90Vac, auto recovery, return difference≥5V Output PROTECTION Over Current ≥55A , auto recovery Over Voltage 4.6~6.5V, auto recovery 5.5~7V, auto recovery Over Temperature Test at40A Ambient temp. Protection when ambient temp. is over 65℃; auto recovery when ambient temp. is lower than 50℃ Housing temp. Protection when temp. of upper housing is over 85℃; auto recovery when it is less than 70℃ Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -30℃~65℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 4) Safety Standards IEC 62368-1, UL62368-1, EN62368-1 approved Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVdc/10mA. Isolation Resistance 10Mohms EMI Conduction & Radiation Compliance to EN55032  Class A EMSImmunity Compliance toEN61000-4-2,4,5,11; OTHERS MTBF >100000Hrs (25℃, Full load),MIL-217 Method 2 Components Stress Method Dimension (L*W*H) 165*55*23mm Packing 24pcs/CTN, 9.2Kgs/CTN Cooling method Power supply fixed on the aluminum plate of 450*450*3mm. NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttp://www.powerld.com.cn.
  • VA-UP200-X-G
    VA-UP200-X-G
    l  AC input: 100 ~ 264Vac l  Built-in Active PFC, PF>0.95 l  Withstand input 300Vac for 60s l  High efficiency, long life and high reliability l  Output protections: OCP/SCP/OPP/OTP l  Wide operating ambient temperature  (-40℃~60℃) l  No fan suitable for quiet environment l  100% full load burn-in test l  PCB with conformal coating l 3 years warranty MODEL VAT-UP200-5-G OUTPUT DC Output 5V Rated Current 50A CurrentRange    Note 1 0~50A Ripple and Noise  Note 2 0~55℃ ≤150mV -40~0℃ ≤400mV Voltage Accuracy 4.9~5.2V Line Regulation 4.9~5.2V Load Regulation 4.9~5.2V Set-up Time ≤2.0S (220Vac input, Full load) Hold up Time ≥5mS(220Vac input, load32A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <±5% INPUT VoltageRange 100Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 88%(220Vac input ,load 50A)    AC Current (max.) <3.5A Inrush Current (Typical) <60A@220Vac     Cold start Power factor >0.95(220Vac input ,40A) Standby power <4W Leakage Current Input—output: ≤0.25mA    Input—PG: ≤3.5mA (264Vac input, 63Hz) PROTECTION Over Power 225~300W @ 100~170Vac input; 275~300W @ 180~264Vac, Hiccup, auto recovery  Over Current 45A-60A @100-170Vac; 55-70A @ 180-264Vac, Hiccup, auto recovery  Shorted Circuit Long-term mode, auto recovery Over Temperature 115℃+5℃(detect on PFC inductance);shut down, auto recovery after the temperature goes down ENVIRONMENT Operating amb. Temp. & Hum. -40℃~60℃; 20%~90%RH No condensing  (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 10Mohms EMI Conduction & Radiation Compliance toEN55022 Class B Harmonic Current Compliance toEN61000-3-2,CLASS D EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 145*60*30mm Packing 36pcs/CTN Cooling method Free air convection NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2.    Measured at 100MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 100uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
    A total of

    4

    pages
#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #