DG-30-SX
Ø Universal AC input range(90~264Vac) Ø High efficiency, long life and high reliability Ø Output protections: OVP/OLP/SCP Ø Wide operating ambient temp (-25℃~70℃) Ø Can be installed on TS-35/7.5 or 35/15 Ø 100% full load burn-in test Ø PCB with conformal coating Ø Suitable for critical applications Ø Cooling by free air convection Ø 3 years warranty SPECIFICATION MODEL DG-30-S12 DG-30-S24 OUTPUT DC Output 12V 24V Rated Current 2.5A 1.25A CurrentRange Note 1 0~2.5A 0~1.25A Ripple and Noise Note 2 10~50℃ ≤50mV ≤70mV -25~10℃ ≤100mV ≤140mV Voltage ADJ. Range 12~14V 24~28V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1% Set-up Time <1.5S @230Vac Full load Hold up Time ≥20mS @230Vac Full load Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange 90Vac~264Vac, 127VDC-370VDC(input V+ connect L, input V- connect N) FrequencyRange 47Hz~63Hz Efficiency ( Typical) 82% @230Vac input, full load 85% @230Vac input, full load AC Current (max.) <0.8A Inrush Current (Typical) 50A/230Vac Cold start Leakage Current Input—output:≤0.25mA Input—PE: ≤3.5mA (264Vac input, 63Hz) PROTECTION Over Load 3~4.0A, hiccup mode, auto recovery 1.5~2.5A, hiccup mode, auto recovery Over voltage 15.0~16.8V, Constant voltage, auto recovery 28.8~31.2V, Constant voltage, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 5%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards UL60950, EN60950 Withstand Voltage Primary-Secondary: 3KVac/10mA; Primary-PE: 1.5KVac/10mA; Secondary-PE: 0.5KVac/10mA Isolation Resistance >10Mohms EMC Emission Compliance to EN55022, EN55024 Class B Harmonic Current Compliance to EN61000-3-2,CLASS A EMC Immunity Compliance to EN61000-4-2,3,4,5,6,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) 590,000Hrs (25℃, Full load) Dimension (L*W*H) 103.7*32*97.5mm Packing 36pcs/CTN, 8Kgs/CTN, 0.04cbm Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttps://www.powerld.com. DIN rail power supply is a kind of switching power supply, which can convert unstable input voltage into stable output voltage. We can meet all industry standards of DIN rail power supply. Learn more, follow us, and leave us a message.