other
Search
Home Search
  • VAT-UP200-X-P-A power supply
    VAT-UP200-X-P-A
    Ø  Universal AC input (90~264Vac) Ø  With Active PFC, PF>0.95 Ø  Surge 300Vac for 60S Ø  High Efficiency, long life and High reliability Ø  Output protections: OLP/OVP/SCP/OPP Ø  1+1 parallel function, current sharing Ø  Wide operating ambient temperature (-40℃~65℃) Ø  Operating altitude up to5000m Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Fanless, quiet working Ø  PCB with conformal coating Ø  Low profile, 30mm Ø  3 years warranty MODEL VAT-UP200-4.2-P-A VAT-UP200-5-P-A OUTPUT DC Output 4.2V 5V Rated Current 40A 40A CurrentRange    Note 1 0~40A 0~40A Peak load 50A(50mS, 220Vac input) Ripple and Noise  Note 2 0~65℃ ≤150MV ≤200MV Voltage Accuracy@-40~65C 4.15~4.4V ±3% Line Regulation/ ±0.5% Load Regulation ±2% Set-up Time @25℃ ≤2S (220Vac input,40A) Hold up Time ≥5mS (220Vac input,32A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% Parallel (current sharing) Current-unbalance< 10% (single PS drive40Aload, the voltage of current share bus is 2.9~4V) INPUT VoltageRange  Note 3 90Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 86% (220Vac input,40A) 88% (220Vac input,40A) AC Current (max.) <3.5A Inrush Current (Typical) <60A@220Vac     Cold start Power Factor @25℃ >0.95 (input 220Vac,40A) Stand by power consumption <4W (input 220Vac) Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA  (input 264Vac, 63Hz) PROTECTION Over Load 44~65A, hiccup mode, auto recovery 44~65A, hiccup mode, auto recovery Over Power 184.8~252W, hiccup mode, auto recovery 220~325W, hiccup mode, auto recovery Over Voltage 4.5~6.5V, hiccup mode, auto recovery 5.2~6.5V, constant voltage Over Temperature 105℃+5℃(detect on temperature controller);shut down, auto recovery after the temperature goes down to65℃ Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~65℃; 20%~90%RH No condensing(refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 4) Safety Standards UL60950-1 2ndEd; IEC 60950-1:2005(2ndEd) ;EN60950-1:2006 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 10Mohms EMI Conduction&Radiation Compliance to EN55022  CLASS B EMSImmunity Compliance toEN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) >200000h (25℃, Full load) Dimension (L*W*H) 133*55*30mm Packing 49PCS/CTN, 15KGS, 0.04CBM Power Good Signal Working properly, port voltage: 3.0~3.5V(output current 0~1mA) Working abnormally, port voltage: 0~0.7V(pull-up resistor > 10K) Cooling method Cooling by free air convection NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttps://www.powerld.com. We provide high-quality LED power supplies for indoor and outdoor, and a variety of specifications and models of LED power supplies are optional, suitable for specific lighting applications in multiple fields.
  • VAT-UP400S-X-60L-A power supply
    VAT-UP400S-X-60L-A
    l  AC input: 90-264Vac l   Built-in Active PFC, PF>0.93 l   Output protections: OLP/SCP/OTP/OPP l   Wide operating ambient temperature  (-40℃~80℃) l   No fan suitable for quiet environment l   100% full load burn-in test l   Long life and high reliability l   High efficiency up to 90% l   Conformal coating l   Low profile, 30mm l   3 years warranty MODEL VAT-UP400S-5-60L-A OUTPUT DC Output 5V Output Pre set voltage 5.0-5.10V (220Vac input, load 0A) Rated Current 80A CurrentRange    Note 1 0~80A Peak load 90A, last 50mS @ 220Vac Ripple and Noise 25~80℃ ≤150mV Voltage Adj. Range 4.15~5.10V Voltage Accuracy ±2.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2.5S (110Vac input, Full load), ≤1S (220Vac input, Full load) Hold up Time ≥10mS(220Vac input, 80% load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5% INPUT VoltageRange 90Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 90%(220Vac input ,full load) AC Current (max.) <5A Inrush Current (Typical) <80A@220Vac     Cold start Power factor >0.93(220Vac input ,full load);  >0.95/(110Vac input ,full load) PROTECTION Over Power 425W~550W, Hiccup mode, auto recovery Over Current 85A~110A, Hiccup mode, auto recovery Shorted Circuit Long-term mode, auto recovery Over Temperature 105℃+5℃(detect on Q1/D1 batten);shut down, auto recovery after the temperature goes down ENVIRONMENT Operating amb. Temp. & Hum. -40℃~80℃; 20%~90%RH No condensing  (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards GB4943-2001; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Leakage Current Input—output: ≤0.25mA    Input—PG: ≤3.5mA (264Vac input,63Hz) Isolation Resistance 10Mohms EMI Conduction & Radiation EN55022, EN55024, FCC Part 15, Class B Harmonic Current EN61000-3-2 CLASS D EMSImmunity EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) >200,000Hrs,full load Dimension (L*W*H) 235*60*30mm Packing 18pcs/CTN Cooling method Free air flow (Fixed to aluminum heatshink of customer’s system) NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 100uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. We cannot guarantee that the final equipment will meet EMC directives, Final product manufactures must be re-confirm that their product meets EMC directives. We provide high-quality LED power supplies for indoor and outdoor, and a variety of specifications and models of LED power supplies are optional, suitable for specific lighting applications in multiple fields.
  • VAT-UP400S-X-60L-P
    VAT-UP400S-X-60L-P
    l  AC input: 90VAC ~ 264VAC l  Built-in Active PFC, PF>0.95  l  High efficiency, long life and high reliability l  Output protections: OLP/SCP/OTP l  Wide operating ambient temperature  (-40℃~80℃) l  No fan suitable for quiet environment l  100% full load burn-in test l  1+1 and redundancy, current sharing function l  Conformal coating l  3 years warranty MODEL VAT-UP400S-5-60L-P OUTPUT DC Output 5V Output Pre set voltage 5.0-5.10V (220Vac input, load 0A) Rated Current 80A  ( PSU fixed on heat sink of square > 400*400*2mm aluminum plate) CurrentRange    Note 1 0~80A Ripple and Noise 25~80℃ ≤150mV 0-25C ≤200mV Voltage Adj. Range 4.15~5.10V Voltage Accuracy ±2.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2.5S (110VAC input, Full load) Hold up Time ≥8mS(220Vac input, 80% load) Temperature Coefficient ±0.03%/℃ Current sharing unbalance <10% (Current sharing bus voltage is 2.9-4V, single PS at 80A load) ) Overshoot and Undershoot <5% INPUT VoltageRange 90Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 88%(220Vac input ,full load) AC Current (max.) <5A Inrush Current (Typical) <80A@220Vac     Cold start Power factor >0.93(220Vac input ,full load);  >0.95/(110Vac input ,full load) PROTECTION Over Power 425W~550W, Hiccup, auto recovery Over Current 85A~110A, Hiccup, auto recovery Shorted Circuit Long-term mode, auto recovery Over Temperature 105℃+5℃(detect on Q1/D1 batten);shut down, auto recovery after the temperature goes down ENVIRONMENT Operating amb. Temp. & Hum. -40℃~80℃; 20%~90%RH No condensing  (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Leakage Current Input—output: ≤0.25mA    Input—PG: ≤3.5mA (264Vac input, 63Hz) Isolation Resistance 10Mohms EMI Conduction & Radiation Compliance to EN55022, EN55024, FCC PART 15  CLASS B Harmonic Current Compliance to EN61000-3-2 CLASS D EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 250*60*30mm Packing TBD Cooling method Free air convection PG SIGNAL Power indicator terminal voltage 1.       Power supply is normal, the signal voltage: 3.0V ~ 3.5V (current 0~1mA) 2.       Power supply is abnormal, the signal voltage: 0V ~ 0.7V, (pull-up resistor is greater than 10kΩ) 3.       Control card to detect POWER GOOD signal port, in order to prevent interference misoperation, Recommended MCU or FPGA detection port to add the 0.01uF decoupling capacitor. NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 100uF parallel capacitor. 3. he SPS is considered a component which will be installed into final equipment. We cannot guarantee that the final equipment will meet EMC directives, Final product manufactures must be re-confirm that their product meets EMC directives.
    A total of

    1

    pages
#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #