other
Search
Home Search
  • PS-45-SX power supply
    PS-45-SX
    Ø  Universal AC input/ Full range (90~264Vac) Ø  High Efficiency, long life and high reliability Ø  Output protections: SCP/OVP/ OLP/OPP Ø  Wide operating ambient temperature (-10℃~60℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  3 years warranty  MODEL PS-45-S12 PS-45-S24 PS-45-S48 OUTPUT DC Output 12V 24V 48V Rated Current 3.7A 1.9A 1A Ripple and Noise  Note 2 0~60℃ ≤120mV ≤120mV ≤120mV -10℃~0℃ ≤200mV ≤200mV ≤200mV Voltage ADJ. Range 11.4~13.2V 22.8~26.4V 45.6~52.8V Voltage Accuracy ±3.0% Line Regulation ±1.0% Load Regulation ±3.0% Set-up Time ≤0.8S @ 230Vac   full load Hold up Time ≥60mS @ 230Vac  full load Temperature Coefficient ±0.05%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange  Note 3 90Vac~264Vac FrequencyRange 47Hz-63Hz Efficiency ( Typical) 220Vac input ≥82% ≥85% ≥86% AC Current (max.) <1A(115VAC)  <0.6A(230VAC) Inrush Current (Typical) <20A@115Vac   <45A@230Vac     Cold start Leakage Current Input to Output:≤0.25mA ; Input to PG:≤3.5mA PROTECTION Over Load 3.9~6.2A 2.0~3.2A 1.1~1.56A Protection type: Hiccup mode, auto recovery Over Voltage 13.8~16.2V 27.6~32.4V 55.2~64.8V Protection type: Constant voltage, Auto recovery Over Power 46.8~75W 48~75W 53~75W Protection type: Hiccup mode, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -10℃~60℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -25℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 4) Safety Standards UL60950-1; EN60950-1:2006 Withstand Voltage Input-Output:3.0KVac/10mA ; Output-PG: 1.5KVac/10mA;Output-PG: 0.5KVdc/10mA Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022 Class B EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 101.6×51×28mm Packing 60PCS/CTN, 11KGS, 0.024CBM Cooling method Cooling by free air convection NOTE 1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.   We are Industrial power supply manufacturer with competitive price and good quality,which are widely recognized and trusted by users and can meet social needs.
  • PS-60-X power supply
    PS-60-X
    Ø  Universal AC input/ Full range Ø  High Efficiency, low power consumption Ø  No load power comsumption<=0.5W Ø  Output protections: SCP/OVP/ OLP Ø  Wide operating ambient temperature (-25℃~70℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø 3 years warranty  MODEL PS-60-5 PS-60-12 PS-60-15 PS-60-24 PS-60-48 OUTPUT DC Output 5.0V 12.0V 15.0V 24.0V 48.0V Rated Current 8.0A 4.5A 3.6A 2.5 A 1.25A Ripple and Noise  Note 2 0~70℃ <50mV <120mV <120mV <120mV <240mV -25℃~0℃ <200mV <300mV <300mV <300mV <360mV Voltage ADJ. Range -5% ~ +10% of rated voltage Voltage Accuracy ±3.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤1.0S (230Vac input, Full load) Hold up Time ≥20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange  Note 3 90Vac~264Vac, 127Vdc~370Vdc FrequencyRange 47Hz-63Hz Efficiency ( Typical) 115Vac input 78% 83% 84% 87% 85% 230Vac input 82% 85% 85% 87% 88% AC Current (max.) <1.5A Inrush Current (Typical) <30A@120Vac   <60A@230Vac     Cold start Leakage Current <0.25mA PROTECTION Over Load 105%~180% of rated output current, hiccup mode,auto recovery Over Voltage 110%~150% of rated output voltage, Constant voltage, Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 4) Safety Standards UL60950-1; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA . Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022, ClassB Harmonic Current Compliance to EN61000-3-2,-3 EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 101.6×50.8×30mm Packing 60PCS/CTN, 12KGS, 0.024CBM Cooling method Cooling by free air convection NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.   We focus on your industrial power supply project needs, Offering reliable quality and high cost-effective products is always our top priority. Effective Communication within 24 hours.
  • PS-60-CX power supply
    PS-60-CX
    Ø  Universal AC input/ Full range (90~264Vac) Ø  High Efficiency, high reliability and long life Ø  Output protections: SCP/OVP/ OLP/OPP Ø  Wide operating ambient temperature (-10℃~65℃) Ø  When 176~264Vac input, free air convection, it is 60W; when 90~175Vac input, 10.5CFM, 60W Ø  When 90~175Vac, free air convection, 45W. Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  2*4 size Ø 2 years warranty     MODEL PS-60-C5 PS-60-C12 PS-60-C15 PS-60-C24 PS-60-C48 OUTPUT DC Output 5.0V 12.0V 15.0V 24.0V 48.0V Rated Current(175~264Vac) 8.0A 5.0A 4.0A 2.5 A 1.25A Ripple and Noise  Note 2 0~65℃ <80mV <120mV <150mV <240mV <300mV -10℃~0℃ <200mV <300mV <360mV <360mV <480mV Voltage ADJ. Range 4.75~5.5V 11.4~13.2V 14.25~16.5V 22.8~26.4V 45.6~52.8V Voltage Accuracy ±2.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time ≤1.0S (230Vac input, Full load) Hold up Time ≥50mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange  Note 3 90Vac~264Vac FrequencyRange 47Hz-63Hz Efficiency(Typical) 230Vac input 80% 83% 84% 85% 86% AC Current (max.) <1.5A Inrush Current (Typical) <30A@120Vac   <60A@230Vac     Cold start Leakage Current Input to Output: <0.25mA; Input to PG: <3.5mA PROTECTION Over Load 10.5~18A 5.25~9A 3.78~6.48A 2.625~4.5A 1.31~2.25A Protection type: Hiccup mode, Auto recovery Over Power 52.5~90W 63~108W 56.7~97.2W 63~108W 63~108W Protection type: Hiccup mode, Auto recovery Over Voltage 5.25~7.5V 12.6~18V 15.75~22.5V 25.2~36V 50.4~72V Protection type: Constant voltage, Auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -10℃~65℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -30℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 4) Safety Standards UL60950-1; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac/10mA; Primary-PG:1.5KVac/10mA;Secondary-PG:0.5KVdc/10mA Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022  Class B EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 101.6×51×29mm Packing 60PCS/CTN, 12KGS, 0.024CBM Cooling method Cooling by free air convection NOTE 1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. We are Industrial power supply manufacturer with competitive price and good quality,which are widely recognized and trusted by users and can meet social needs.
  • PD-H35SX power supply
    PD-H35SX
    Ø  No Load power consumption<0.5W Ø  High AC input Ø  Miniature size,high power density,high efficiency,long life and high reliability Ø  Withstand 300VA surge input for 5 sec. Ø  Output protections: OLP/OVP/SCP/OPP Ø  Wide operating ambient temp (-25℃~70℃),100% @50℃、70%@70℃ Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Suitable for critical applications Ø  3 years warranty     SPECIFICATION                                              MODEL PD-H35S12 OUTPUT DC Output   Rated Current 2.6A Current Range      0~2.6A Ripple and Noise  Note 2 -25~70℃   Voltage ADJ.  Range 11.4~12.6V Voltage Accuracy ±2.0% Line Regulation ±1.0% Load Regulation ±2.0% Set-up Time <1.0S (230Vac input, Full load) Hold up Time >20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range     Frequency Range 47Hz~63Hz Efficiency ( Typical) 82% AC Current (max.) 0.7A 2.5A Inrush Current (Typical) <40A@230Vac      Cold start Leakage Current Input—output:<3.5mA     Input—PG:<0.25mA PROTECTION Over Load   Over power 37.8~54W, constant power Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum.   Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards   Withstand Voltage Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022 ClassB; FCC PART15 B EMS Immunity Compliance to EN61000-4-2,4,5,8,11; OTHERS MTBF (MIL-HDBK-217F)   Dimension  (L*W*H) 94.5×51.5×29.5mm Packing 48PCS/CTN, 10.42KGS, 0.03CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. 4. Powerld offer accessories for Din-35 rail bar. Please contact sales staff for details. We are professional manufacturer engaged in the research, development, production, sale and service of Industrial power supply,We sincerely look forward to cooperating with you and creating the future together!
  • PS-100-X power supply
    PS-100-X
    Ø  High AC input 176~264Vac Ø  High power density,High effiency and reliability Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temperature (-20℃~70℃) Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø 3’’*5’’ compact size Ø  2 years warranty MODEL PS-100-12 PSGZM-H25S8.5 GZM-H25S12II PS-100-24 OUTPUT DC Output 12V 8.5V 12V 24V Rated Current 8.33A 3A 2 A 4.16A CurrentRange   Note 1 0~8.33A 0~3A 0~2A 0~4.16A Ripple and Noise Note 2 0~70C 100mV 120mV -20C~0 120mV 85mV 120mV 120mV Voltage ADJ. Range ±10% of rated output voltage Voltage Accuracy ±1.0% ±3.0% ±5.0% ±2.0% Line Regulation ±0.5% ±0.5% ±1.0% ±0.5% Load Regulation ±1.0% ±2.0% ±1.0% ±1.0% Set-up Time <2.0S (220Vac input, Full load) Hold up Time >10mS(220Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshootand Undershoot <5.0% INPUT VoltageRange   176Vac~264Vac FrequencyRange 47Hz--63Hz Efficiency ( Typical) 83% 85% AC Current (max.) 1.5A 0.5A 2.5A 0.3A 1.5A Inrush Current (Typical) <50A@220Vac    Cold start Leakage Current Input-Output: <0.25mA; Output-PG: <3.5mA PROTECTION Over Current 105%~150% of rated output current, hiccup mode, auto recovery Over Voltage 110%~140% of rated output voltage, hiccup mode, auto recovery Short Circuit Long term mode, Auto recovery ENVIRONMENT OperatingambTemp& Hum -20℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   Note 3 Safety Standards GB4943-2001; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA .Secondary-PG:0.5KVDC;≤10mA . Isolation Resistance 100M ohms EMI Conduction&Radiation Compliance to EN55022(CISPR22)ClassB EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8;ENV50204A, heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 127×76.2×32.5mm Packing 24PCS/CTN, 8.5KGS, 0.02CBM Cooling method Cooling by free air convection NOTE 1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. Focus on the development of Industrial power supply for many years,make efforts to meet customers' requirements and search for long-term cooperation.24 hours online service affiliates you to contact us.
  • PSF-125-X power supply
    PSF-125-X
    Ø  Universal AC input/ Full range Ø  High power density,High effiency and reliability Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temperature (-20℃~70℃) Ø  Build-in remote sense function Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  3 years warranty MODEL PSF-125-5 GZM-H25S8.5 PSF-125-12 GZM-H25S12II PSF-125-15 PSF-125-24 PSF-125-36 PSF-125-48 OUTPUT DC Output 5V 8.5V 12V 12V 15V 24V 36V 48V Rated Current 20A 3A 10.5A 2 A 8.4A 5.2A 3.5A 2.6A CurrentRange   Note 1 0~20A 0~3A 0~10.5A 0~2A 0~8.4A 0~5.2A 0~3.5A 0~2.6A Ripple and Noise Note 2 100mV 85mV 100mV 120mV 100mV 100 mV 120 mV 150 mV Voltage ADJ. Range ±10% of rated output voltage Voltage Accuracy ±2.0% ±3.0% ±2.0% ±5.0% ±2.0% ±2.0% ±2.0% ±2.0% Line Regulation ±0.5% ±0.5% ±0.5% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% Load Regulation ±2.0% ±2.0% ±2.0% ±1.0% ±2.0% ±2.0% ±2.0% ±2.0% Set-up Time <=1200mS (230Vac input, Full load)   <=2500mS (115Vac input, Full load) Hold up Time >=17mS(115/230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshootand Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac,127Vdc~370Vdc FrequencyRange 47Hz--63Hz Power Factor(Typical) PF>0.98/115VAC   PF>0.93/230VAC Efficiency ( Typical) 82%/115Vac 85%/115Vac 85%/115Vac 85%/20Vac 86%/115Vacin 86%/115Vac 84%/230Vac 87%/230Vac 87%/230Vac 87%/230Vac 88%/230Vac 88%/230Vac AC Current (max.) 1.5A 0.5A 2.5A 1.5A 0.3A 1.5A 1.5A 1.5A 1.5A Inrush Current (Typical) 60A@230Vac  30A@115Vac  Cold start Leakage Current <3.5mA PROTECTION Over Current 105%~150% of rated output current, hiccup mode, auto recovery Over Voltage 120%~150% of rated output voltage,hiccup mode Short Circuit Auto recovery ENVIRONMENT OperatingambTemp& Hum -20℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   Note 3 Safety Standards GB4943-2011; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA .Secondary-PG:0.5KVDC;≤10mA . Isolation Resistance 100M ohms EMI Conduction&Radiation Compliance to EN55022(CISPR22)ClassB Harmonic Current Compliance to EN61000-3-2,-3 EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA OTHERS MTBF (MIL-HDBK-217F) More than 100,000Hrs (25℃, Full load) Dimension (L*W*H) 127×76×30.5mm Packing 21PCS/CTN, 8.46KGS, 0.015CBM Cooling method Cooling by free air convection NOTE 1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com Focus on the development of Industrial power supply for many years,make efforts to meet customers' requirements and search for long-term cooperation.24 hours online service affiliates you to contact us.
  • PSF-200-X power supply
    PSF-200-X
    Ø  Universal AC input/ Full range Ø  Built-in Active PFC function Ø  Withstand 300Vac surge input for 5 sec. Ø  High efficiency up to 90%(typ) Ø  Output protections: OLP/OVP/SCP/OPP Ø  Wide operating ambient temperature (-20℃~70℃) Ø  All using105℃long life electrolytic capacitors. Ø  Free air convection for 150W and 200W with 20.5CFM forced air Ø  100% full load burn-in test Ø 5’’*3’’ compact size Ø  3 years warranty MODEL PSF-200-12 GZM-H25S12II PSF-200-24 PSF-200-27 PSF-200-48 OUTPUT DC Output 12V 8.5V 12V 12V 24V 27V 48V Rated Current 16.6A 3A 10.5A 2 A 8.4A 7.4A 4.167A CurrentRange(convection)    0~12.5A 0~3A 0~10.5A 0~2A 0~6.25A 0~5.5A 0~3.13A CurrentRange(20.5CFM fan) 0~16.6A 0~8.4A 0~7.4A 0~4.167A Ripple and Noise Note 20<Ta≤70℃ 0<Ta≤70℃ 120mVp-p 85mV 100mV 120mV 200 mVp-p 100 mVp-p 120 mVp-p -20≤Ta≤0℃ 200 mVp-p 200 mVp-p 150 mVp-p 240 mVp-p Voltage ADJ. Range ±10% of rated output voltage Voltage Accuracy ±1.0% ±3.0% ±5.0% ±2.0% ±2.0% Line Regulation ±0.5% ±0.5% ±1.0% ±0.5% ±0.5% Load Regulation ±1.0% ±2.0% ±1.0% ±2.0% ±2.0% Set-up Time ≤2S (230VAC input, Full load)& ≤4S (115VAC input, Full load) Hold up Time ≥16mS/150W 10mS/200W(115 / 230VAC IN AT FULL LOAD) Temperature Coefficient ±0.03%/℃ Overshootand Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac,127Vdc~370Vdc FrequencyRange 47Hz--63Hz Power Factor(Typical) PF>0.98/115VAC   PF>0.95/230VAC Efficiency ( Typical) ≥89% ≥89% ≥89% ≥90% AC Current (max.) <3A 2.5A 1.5A 0.3A 1.5A 1.5A 1.5A 1.5A Inrush Current (Typical) <50A@230Vac  <30A@115Vac  Cold start Leakage Current ≤3.5mA PROTECTION Over Current 105%~150% of rated output current, hiccup mode, auto recovery Over Power 105%~150% of rated output current, hiccup mode, auto recovery Over Voltage 125%~150% of rated output voltage, hiccup mode, auto recovery Short Circuit Long-term, Auto recovery ENVIRONMENT OperatingambTemp& Hum -20℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   Note 3 Safety Standards UL60950-1; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA .Secondary-PG:0.5KVDC;≤10mA . Isolation Resistance 100M ohms EMI Conduction&Radiation Compliance to EN55022,EN55024 ClassB Harmonic Current Compliance to EN61000-3-2,-3 EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11;EN55024,EN61000-6-2heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 128×76.5×34.6mm(5’’*3’’) Packing 21PCS/CTN, 8.46KGS, 0.015CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. We focus on your industrial power supply project needs, Offering reliable quality and high cost-effective products is always our top priority. Effective Communication within 24 hours.
  • DG-240-X power supply
    DG-240-X
    Ø  Universal AC input range(85~264Vac) Ø  Support 1+1 or N+1 redundant system(suggest to use redundancy modules.) Ø  Built-in active PFC,PF>0.95 Ø  High efficiency up to 94% Ø  Built-in current sharing function Ø  Built-in current limiting circuit Ø  Output protections: OVP/OLP/SCP/OTP Ø  Wide operating ambient temp (-25℃~70℃) Ø  150%(360W) peak load capacity Ø  Easy Fuse Tripping due to High Overload Current Ø  Excellent Partial Load Efficiency Ø  Built-in DC OK relay contact Ø  Can be installed on TS-35/7.5 or TS-35/15 Ø  100% full load burn-in test Ø  Suitable for critical applications Ø  Ultra-slim, 45mm width Ø  3 years warranty SPECIFICATION                                                MODEL DG-240-24 ABS-75-12 DG-240-48 OUTPUT DC Output 24V 12V 48V Rated Current 10A 6A 5A Current Range     Note 1 0~10A 0~6A 0~5A Ripple and Noise  Note 2 0~70℃ ≤240mV ≤480mV -25℃ ≤480mV ≤480mV Voltage ADJ.  Range 24~28V 48~56V Voltage Accuracy ±3.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <3S@230Vac  Hold up Time ≥20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   85Vac~264Vac, 127Vdc-375Vdc Frequency Range 47Hz~63Hz Power Factor (typical) 0.99/110Vac     0.95/230Vac Efficiency ( Typical) 94% ≥84% 93% ≥88% AC Current (max.) <3.0 A/100Vac        <1.5A/230Vac Inrush Current (Typical) <20A/110Vac      <40A/230Vac   Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Load 110%~150% of rated current, Constant current limiting for some time(150% of rated current, last 3S) then PS stop working for 7S,after 7S,if the load <=rated current, PS will work normally, auto recovery Over voltage 29~33V, constant voltage, Auto recovery 58~63V, constant voltage, Auto recovery Over temperature 105±5℃, detect on heat sink of power transistor; shut down O/P, auto recovery after temperature goes down. Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃;  20%~90%RH  No condensing Storage Temp. & Hum. -40℃~85℃;  5%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards meet UL508, UL60950, EN60950 Withstand Voltage Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:2.5KVac; ≤10mA. Secondary-PG:0.5KVac≤20mA. Isolation Resistance ≥100M ohms EMC Emission Compliance to EN55022, EN55024, FCC PART 15 Class B Harmonic Current Compliance to EN61000-3-2, CLASS A EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 300,000Hrs (25℃, Full load) Dimension  (L*W*H) 45*124*119mm Packing 24pcs/CTN, 21Kgs/CTN, 0.045cbm Cooling method Cooling by free air convection Additional function Power boost 150% of rated current Parallel function support DC-OK V On: when output voltage is up to 90% of rated output voltage V Off: when output voltage is down to 80% of rated output voltage DC-OK relay contact rating Max 30V/1A or 60V/0.3A or 30Vac/0.3A Resistive load NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • PD-75-X Power Supply
    PD-75-X
    Ø  No Load power consumption<0.5W Ø  Withstand 300VA surge input for 5 sec. Ø  High Efficiency, High reliability and long life Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temperature (-25℃~70℃) Ø  Operating altitude up to5000m Ø  All using105℃long life electrolytic capacitors. Ø  PCB soldering side with conformal coating Ø  100% full load burn-in test Ø  3 years warranty      SPECIFICATION                                              MODEL PD-75-5 PD-75-12 PD-75-15 PD-75-24 PD-75-48 OUTPUT DC Output 5V 12V 15V 24V 48V Rated Current 12A 6A 5A 3.2.A 1.6A Current Range     Note 1 0~12A 0~6A 0~5A 0~3.2A 0~1.6A Ripple and Noise Note 2 0~70℃ <50mV <80mV <80mV <80mV <120mV -25~0℃ <80mV <200mV <200mV <200mV <240mV Voltage ADJ.  Range 4.75~5.5V 11.4~13.2V 14.25~16.5V 22.8~26.4V 45.6~52.8V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time ≤1S(230Vac input, Full load) Hold up Time ≥20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   90Vac~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) 79% 84% 86% 86.5% 88% AC Current (max.) <2.5A Inrush Current (Typical) <60A@230Vac      Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA         (264Vac input, 63Hz) PROTECTION Over Load 12.6~18A 6.3~9A 5.25~7.5A 3.36~4.8A 1.7~2.43A Protection type: 5V, hiccup mode; others, constant power, Auto recovery Over Voltage 5.5~7.5V 13.2~18V 16.5~22.5V 26.4~36V 52.8~72V Protection type: constant voltage, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃;  20%~90%RH  No condensing((refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac/ 10mA .Primary-PG:1.5KVac/ 10mA. Secondary-PG:0.5KVDC/ 10mA. Isolation Resistance 100M ohms EMI Conduction& Radiation Compliance to EN55022 Class B / FCC Part15 B Harmonic Current Compliance to EN61000-3-2, Class A EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 129×98×38mm Packing 30PCS/CTN, 14.2KGS, 0.044CBM Cooling method Cooling by free air convection NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.        The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. 4.  Powerld offer accessories for Din-35 rail bar. Please contact sales staff for details. We always can deliver high-end quality industrial power supply products to our customers on time.Quality products,excellent service,we also welcome OEM and ODM industrial power supply orders.
    A total of

    4

    pages
#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #