  • VAT260UPXAA
    VAT260UPXAA
    Ø  Universal AC input (90~264Vac) Ø  With Active PFC, PF>0.95 Ø  Stand-by power consumption: 0.35W Ø  High Efficiency, long life and High reliability Ø  Output protections: OCP/OVP/SCP/OTP Ø  Wide operating ambient temperature (-30℃~65℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Fanless, quiet working Ø  PCB with conformal coating Ø  Low profile, 23mm Ø  3 years warranty    Ø  UL/CE/CCC/CB approved MODEL VAT260UP4.2AA VAT260UP5AA OUTPUT DC Output 4.2V 5V Rated Current 50A 50A CurrentRange    Note 1 0~50A 0~50A Ripple and Noise  Note 2 0~65℃ ≤250mV ≤300mV -30~0℃ ≤500mV ≤600mV Voltage Accuracy ±3% Set-up Time @25℃ ≤4S (220Vac input, 50A) Temperature Coefficient ±0.03%/℃ Overshoot ≤5.0% INPUT Voltage Range 90Vac~264Vac Rated input voltage range 100~240Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 90% @220Vac input, 50A ( 91% @220Vac, 60% load) AC Current (max.) <3.5A Inrush Current (Typical) <80A@220Vac     Cold start Power Factor @25℃ >0.95 (input 220Vac, 50A) Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA  (input 264Vac, 63Hz) Input Protection Under voltage protection point 55Vac~85Vac, shut down Under voltage recovery point 60Vac-90Vac, auto recovery, return difference≥5V Output PROTECTION Over Current ≥55A , auto recovery Over Voltage 4.6~6.5V, auto recovery 5.5~7V, auto recovery Over Temperature Test at40A Ambient temp. Protection when ambient temp. is over 65℃; auto recovery when ambient temp. is lower than 50℃ Housing temp. Protection when temp. of upper housing is over 85℃; auto recovery when it is less than 70℃ Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -30℃~65℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 4) Safety Standards IEC 62368-1, UL62368-1, EN62368-1 approved Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVdc/10mA. Isolation Resistance 10Mohms EMI Conduction & Radiation Compliance to EN55032  Class A EMSImmunity Compliance toEN61000-4-2,4,5,11; OTHERS MTBF >100000Hrs (25℃, Full load),MIL-217 Method 2 Components Stress Method Dimension (L*W*H) 165*55*23mm Packing 24pcs/CTN, 9.2Kgs/CTN Cooling method Power supply fixed on the aluminum plate of 450*450*3mm. NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttp://www.powerld.com.cn.
  • VA-UP200-X-G
    VA-UP200-X-G
    l  AC input: 100 ~ 264Vac l  Built-in Active PFC, PF>0.95 l  Withstand input 300Vac for 60s l  High efficiency, long life and high reliability l  Output protections: OCP/SCP/OPP/OTP l  Wide operating ambient temperature  (-40℃~60℃) l  No fan suitable for quiet environment l  100% full load burn-in test l  PCB with conformal coating l 3 years warranty MODEL VAT-UP200-5-G OUTPUT DC Output 5V Rated Current 50A CurrentRange    Note 1 0~50A Ripple and Noise  Note 2 0~55℃ ≤150mV -40~0℃ ≤400mV Voltage Accuracy 4.9~5.2V Line Regulation 4.9~5.2V Load Regulation 4.9~5.2V Set-up Time ≤2.0S (220Vac input, Full load) Hold up Time ≥5mS(220Vac input, load32A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <±5% INPUT VoltageRange 100Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 88%(220Vac input ,load 50A)    AC Current (max.) <3.5A Inrush Current (Typical) <60A@220Vac     Cold start Power factor >0.95(220Vac input ,40A) Standby power <4W Leakage Current Input—output: ≤0.25mA    Input—PG: ≤3.5mA (264Vac input, 63Hz) PROTECTION Over Power 225~300W @ 100~170Vac input; 275~300W @ 180~264Vac, Hiccup, auto recovery  Over Current 45A-60A @100-170Vac; 55-70A @ 180-264Vac, Hiccup, auto recovery  Shorted Circuit Long-term mode, auto recovery Over Temperature 115℃+5℃(detect on PFC inductance);shut down, auto recovery after the temperature goes down ENVIRONMENT Operating amb. Temp. & Hum. -40℃~60℃; 20%~90%RH No condensing  (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 10Mohms EMI Conduction & Radiation Compliance toEN55022 Class B Harmonic Current Compliance toEN61000-3-2,CLASS D EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 145*60*30mm Packing 36pcs/CTN Cooling method Free air convection NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2.    Measured at 100MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 100uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
  • VAT-UP300L-X-E
    VAT-UP300L-X-E
    Ø  Universal AC input (90~264Vac) Ø  With Active PFC, PF>0.95 Ø  High Efficiency, long life and High reliability Ø  Surge 300Vac for 60s Ø  Output protections: OLP/OVP/SCP/OPP Ø  Wide operating ambient temperature (-40℃~65℃) Ø  Operating altitude up to5000m Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Fanless, quiet working Ø  PCB both side with conformal coating        Ø  2 years warranty  MODEL VAT-UP300L-5-E VAT-UP300L-4.2-E OUTPUT DC Output 5V 4.2V Rated Current 60A 60A Current Range     Note 1 0~60A 3~60A Peak load 70A (50mS, 220Vac input) Ripple and Noise  Note 2 0~65℃ ≤200mV (100M bandwidth) ; ≤150MV (20M bandwidth) -40℃ ≤400mV (100M bandwidth) Voltage Accuracy ±3% Line Regulation/ ±0.5% Load Regulation ±2% Set-up Time ≤3S (220Vac input,60A) Hold up Time ≥4mS (220Vac input,60A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   Note 3 90Vac~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) 110Vac input ≥87% ≥86% 230Vac input ≥90% ≥88% AC Current (max.) <5A Inrush Current (Typical) <30A@220Vac      Cold start Power Factor @25℃ >0.95  (input 220Vac,60A) Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA   (input 264Vac, 63Hz) PROTECTION Over Load 63~80A, hiccup mode, auto recovery 63~90A, hiccup mode, auto recovery Over Power 350~450W, hiccup mode, auto recovery 264~378W, hiccup mode, auto recovery Over Voltage 5.2~6.5V, constant voltage 4.5~5.5V, constant voltage Over Temperature 95℃+5℃(detect on temperature controller);shut down, auto recovery after the temperature goes down to65℃ Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~65℃;  20%~90%RH  No condensing(refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC   (Note 4) Safety Standards UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 10M ohms EMI Conduction&Radiation Compliance to EN55022, EN55024, FCC PART 15   Class B Harmonic Current Compliance to EN61000-3-2  Class D EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11 OTHERS MTBF (MIL-HDBK-217F) >200000h (25℃, Full load) Dimension  (L*W*H) 190×99×29.8mm Packing TBD Cooling method Cooling by free air convection NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • VAT-HP260-X-C
    VAT-HP260-X-C
    Ø  High voltage input (176~264Vac) Ø  With Active PFC, PF>0.95 Ø  Surge 300Vac for 60S Ø  High Efficiency, long life and High reliability Ø  Output protections: OCP/SCP/OPP/OTP Ø  Wide operating ambient temperature (-40℃~50℃) Ø  Operating altitude up to5000m Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Fanless, quiet working Ø  PCB with conformal coating Ø  Low profile, 30mm        Ø  3 years warranty MODEL VAT-HP260-5.2-C OUTPUT DC Output 5.2V Rated Current 40A Current Range     Note 1 0~50A Peak load 55A Ripple and Noise  Note 2 0~50℃ ≤150mV -40~0℃ ≤400mV Voltage Accuracy@-40~50C ±3% Line Regulation ±0.5% Load Regulation ±2% Set-up Time @25℃ ≤2S (220Vac input,40A) Hold up Time ≥5mS (220Vac input,32A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <±5% INPUT Voltage Range   Note 3 176~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) 92%  (220Vac input,40A) AC Current (max.) <3.5A Inrush Current (Typical) <60A@220Vac      Cold start Power Factor @25℃ >0.95  (input 220Vac,40A) Stand by power consumption <4W Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA   (input 264Vac, 63Hz) PROTECTION Over Current 55~80A , hiccup mode, auto recovery Over Power 286~416W, hiccup mode, auto recovery Over Temperature 115℃+5℃(detect on temperature protector);shut down, auto recovery after ambient temperature goes down to 50℃(temperature protector goes down to 85℃+15℃) Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~50℃;  20%~90%RH  No condensing(refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC   (Note 3) Safety Standards GB4943 / EN60950 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 10M ohms EMI Conduction&Radiation Compliance to EN55022, EN55024, FCC PART 15   CLASS B Harmonic current Compliance to EN61000-3-2, Class D EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) >200000h (25℃, Full load) Dimension  (L*W*H) 133*55*30mm Packing 49PCS/CTN, 15KGS, 0.04CBM Cooling method Cooling by free air convection NOTE 1.   All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.   Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • VAT-H300S-X-60L
    VAT-H300S-X-60L
    Ø  High AC input (180-264Vac) Ø  Long life and High reliability Ø  High efficiency up to 89% Ø  Output protections: SCP/OPP/OLP Ø  Wide operating ambient temperature (-40℃~65℃) Ø  @-40C, PS can work normally Ø  Altitude up to 5000m Ø  PCB with conformal coating Ø  100% full load burn-in test Ø  2 years warranty MODEL VAT-H300S-5-60L OUTPUT DC Output 5V Rated Current 60A Current Range     Note 1 0~60A Peak load 65A, last 100mS /220Vac Ripple and Noise  Note 2 25~65℃ ≤150mV 0~25℃ ≤200mV Voltage ADJ.  Range 4.15~5.08V Voltage Accuracy ±2.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2S (220VAC input, Full load) Hold up Time ≥10mS (220VAC input, 80% load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   180Vac~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) 89%(220Vac input, full load) AC Current (max.) <3.5A Inrush Current (Typical) <100A@220Vac      Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Power 315~450W, hiccup mode, auto recovery Over Current 63~90A, hiccup mode, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~65℃;  20%~90%RH  No condensing Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards GB4943/ EN60950 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance 10M ohms EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11 OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 208*60*30mm Packing TBD Cooling method Free air convection NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.  The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
  • CMG-H150D24G+12-M
    CMG-H150D24G+12-M
    Ø  High voltage input, 176~264Vac Ø  High Efficiency, long life and High reliability Ø  Output protections: SCP/OVP/OLP/OPP Ø  Wide operating ambient temperature (-25℃~65℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  2 years warranty             Ø  Isolated Dual Outputs MODEL CMG-H150D24G+12-M OUTPUT DC Output V1 24V V2 12V Rated Current V1 6A V2 5A      Current Range  Note 3 V1 0.5~5.0A(5.0Ais recommended) V2 0.3~3.0A(3.0Ais recommended) Ripple and Noise Note4 0~65℃ V1 240mV V2 120mV Ripple and Noise -25~0℃ V1 480mV V2 240mV Voltage ADJ.  Range 21.6~26.4V Voltage Accuracy V1 ±1.0% V2 ±10.0% Line Regulation V1 ±0.5% V2 ±1.0% Load Regulation V1 ±3.0% V2 ±10.0% Set-up Time <1.5S (220Vac input, V1 @ 5A, V2 @ 3.0A) Hold up Time >20mS(220Vac input, V1 @ 5A, V2 @ 3.0A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   176Vac~264Vac Frequency Range 47Hz--63Hz Efficiency ( Typical) ≥80% (220Vac input, V1 @5A, V2 @3.0A) AC Current (max.) <1.9A Inrush Current (Typical) <50A@220Vac      Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Power 157~225W, Hiccup mode, auto recovery Over Current V1: 5.5~8.0A, Hiccup mode, auto recovery Over Voltage V1: 25.2~36V, Hiccup mode, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~65℃;  20%~90%RH  No condensing Storage Temp. & Hum. -30℃~85℃;  10%~95%RH  No condensing SAFETY &EMC   (Note 5) Safety Standards GB4943/ EN60950 Withstand Voltage Primary-Secondary:3.0KVac /10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA.  Output V1—V2: 0.5KVDC/10mA. Test time:1 min Isolation Resistance 10M ohms EMI Conduction&Radiation Compliance to EN55022, CLASS B Harmonic Current Compliance to EN61000-3-2,CLASS A EMS Immunity Compliance to EN61000-4-2,4,5,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 199×99×38mm Packing 20PCS/CTN, 15KGS, 0.04cbm Cooling method Cooling by free air convection NOTE   1.     Total output power can’t exceed 150W, Label is marked by the Max current. Recommend the loading is 24V/5A,12V/3.0A.  2.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 3.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 4.        The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
  • GST-H150S18-M Power supply
    GST-H150S18-M
    SPECIFICATION                                                       MODEL GST-H150S18-M OUTPUT DC Output 18V Rated Current 8.33A Current Range     Note 1 0~8.33A Ripple and Noise   Note 2 0≤Ta≤50℃ ≤180mVpp -25≤Ta≤0℃ ≤400mVpp Voltage ADJ.  Range 17~20V Voltage Accuracy ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% Load Regulation ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% Set-up Time ≤4S(220Vac input, Full load) Hold up Time ≥16mS(220Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   176-264Vac Frequency Range 47Hz--63Hz Efficiency ( Typical)@25℃ ≥84%@Typ. AC Current (max.) <2.5A (220Vac) Inrush Current (Typical) <50A@220Vac Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Load 8.75~12.5A, hiccup mode, auto recovery Over power 157.5~225W, hiccup mode, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~50℃;  20%~90%RH  No condensing;( refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC   (Note3) Safety Standards GB4943/EN60950 Withstand Voltage Primary-Secondary: 3.0KVac/10mA.Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 10M ohms EMS Immunity Compliance to EN61000-4-2,4,5,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 199×99×38mm Packing 20PCS/CTN, 15.2kgs, 0.053CBM Cooling method Cooling by free air convection NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.        The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. Our industrial power supply products enjoy great popularity among customers for our good quality and competitive price.We also welcome OEM and ODM orders.
  • VAT-UP200S-4.5-55L
    VAT-UP200S-4.5-55L
    AC input: 90~264Vac Built-in Active PFC, PF>0.95 High efficiency, long life and high reliability Output protections: OCP/OVP/SCP/OPP No fan suitable for quiet environment Wide operating ambient temperature  (-40℃~65℃) Altitude up to 5000m 100% full load burn-in test Conformal coating 3 years warranty MODEL VAT-UP200S-4.5-55L OUTPUT DC Output 4.5V Rated Current 40A   ( PSU bottom fixed on heat sink of square > 250*250*3mm aluminum plate) Current Range     Note 1 0~40A Ripple and Noise 25~65℃ ≤150mV 0~25C ≤200mV Voltage Adj. Range 2.8~5.10V Voltage Accuracy ±2.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2S (230Vac input, Full load) Hold up Time ≥10mS(220Vac input , 80% load) Temperature Coefficient ±0.03%/℃ Overshoot <5% INPUT Voltage Range 90Vac~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) 89%(230Vac input ,full load) AC Current (max.) <3A Inrush Current (Typical) <80A@220Vac      Cold start Power factor PF>0.98/120VAC    &    PF>0.95/230VAC   (at full load) PROTECTION Over Power 202.5W~270W, Hiccup, auto recovery Over Voltage 5.2~6V, constant voltage, auto recovery Over Current 45A~60A, Hiccup, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~65℃;  20%~90%RH  No condensing   (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Leakage Current Input—output: ≤0.25mA     Input—PG: ≤3.5mA  (264Vac input, 63Hz) Isolation Resistance 10M ohms EMI Conduction Compliance to EN55022, EN55024, FCC PART 15   CLASS A EMI Radiation Compliance to EN55022, EN55024, FCC PART 15   CLASS B Harmonic Current Compliance to EN61000-3-2  CLASS D EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25C, full load) Dimension  (L*W*H) 165*55*26.5mm Packing 16pcs/CTN Cooling method PSU bottom fixed on heat sink of square > 250*250*3mm aluminum plate or forced air convection NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 100uF parallel capacitor. 3.  The SPS is considered a component which will be installed into final equipment. We cannot guarantee that the final equipment will meet EMC directives, Final product manufactures must be re-confirm that their product meets EMC directives.
  • PSF-230S Medical power supply
    PSF-230S
    Ø Universal input 85~264Vac or 120~370Vdc Ø  Built-in Active PFC, PF>0.95 Ø  140W free air convection, 230W force air Ø  No load power consumption<0.3W Ø  Extremely low leakage current<0.1mA Ø  12V/0.5A fan supply Ø  Output protections: SCP/OVP/OCP/OTP Ø  Wide operating ambient temperature (-40℃~70℃) Ø  Operating altitude up to 5000m Ø  4.07’’*2’’ *1’’Compact size Ø  Suitable for BF applications Ø  Fit for Class I & Class II configuration        Ø 3 years warranty  MODEL PSF-230S-12 PSF-230S-24 PSF-230S-36 PSF-230S-48 OUTPUT DC Output 12V 24V 36V 48V Rated Current (free air convection) 11.7A (140.4W) 5.83A (139.92W) 3.9A (140.4W) 2.92A (140.16W) Rated Current (13CFM forced air) 19.2A (230.4W) 9.58A (229.92W) 6.39A (230.04W) 4.79A (229.92W) Ripple and Noise  Note 2 0~70℃ 100mV -40℃~0℃ 200mV Voltage ADJ.  Range 11.4~12.6V 22.8~25.2V 34.2~37.8V 45.6~50.4V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% ±0.5% Set-up Time ≤1.5S (230Vac input, Full load); ≤3.0S (115Vac input, full load) Hold up Time ≥12mS @115Vac input ;  ≥16mS @230Vac input   Full load Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT Voltage Range   Note 3 85~264Vac/120~370Vdc Rated input voltage range 100~240Vac Frequency Range 47Hz-63Hz Efficiency ( Typical) 93% 94% 94% 94% Power Factor(Typical) PF>0.99/115Vac, PF>0.95/230Vac  full load AC Current (max.) ≤3 A/115Vac   ≤1.5 A/230Vac  full load Inrush Current (Typical) 60A/230Vac      Cold start Leakage Current Input to PG: ≤0.25mA    Input to output: ≤0.1mA  PROTECTION Over Current 21.1~34.5A 10.5~17.2A 7~11.5A 5.27~8.62A Protection type: Hiccup mode, auto recovery Over Power 110%~180%, Hiccup mode, auto recovery Over Voltage ≤16V ≤32V ≤48V ≤60V Protection type: Re-power on Over temperature Shut down when temperature is too high; auto recovery when temperature is low Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~70℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing Operating altitude (Note 3) 5000 meters SAFETY &EMC   (Note 4) Safety Standards IEC62368 / IEC60601 Withstand Voltage Primary-Secondary: 4KVac/10mA; Primary to PG: 1.5KVac/10mA; Secondary-PG: 1.5Vac/10mA Isolation Resistance 50M ohms Isolation Level Input-output 2*MOPP Input-FG 1*MOPP Output-FG 1*MOPP EMI Conduction&Radiation Compliance to EN55032 Class B Harmonic Current Compliance to EN61000-3-2, Class D EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 103.5*50.8*25.4mm (4.07’’*2’’*1’’ inch) Packing TBD Cooling method 140W free air convection; 230W with 13CFM forced air NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.     The ambient temperature derating of 0.5℃/100m for operating altitude higher than 2000m. 4. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.