other
Search
Home Search
  • VAT-UP300S-X-60L-A power supply
    VAT-UP300S-X-60L-A
    l   AC input: 90 ~ 264Vac l   Built-in active PFC function, PF>0.95 l  High efficiency, long life and high reliability l   Output protections: OCP/SCP /OTP l   Wide operating ambient temperature (-40℃~65℃) l   Operating altitude up to 3000m l   100% full load burn-in test l   Conformal coating l   No fan suitable for quiet environment l   3 years warranty MODEL VAT-UP300S-5-60L-A VAT-UP300S-4.6-60L-A OUTPUT DC Output 5V 4.6V Rated Current 60A 60A CurrentRange    Note 1 0~60A 0~60A Peak load 70A, last 50mS at 220Vac Ripple and Noise 25~65℃ ≤150mV 0~25℃ ≤200mV Voltage Adj. Range 3.3~5.10V Voltage Accuracy ±2.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2.0S (220Vac input, Full load) Hold up Time ≥5mS(220Vac ,80% load) Temperature Coefficient ±0.03%/℃ Overshoot <5% INPUT VoltageRange 90Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 90% 90% AC Current (max.) <5A Inrush Current (Typical) <60A@220Vac     Cold start Power factor >0.95(220Vac input ,full load) PROTECTION Over Power 325W~450W, Hiccup mode, auto recovery Over Current 65A~90A, Hiccup mode, auto recovery Shorted Circuit Long-term mode, auto recovery Over Temperature 115℃+5℃(detect on L4/C1);shut down, auto recovery after the temperature goes down ENVIRONMENT Operating amb. Temp. & Hum. -40℃~65℃; 20%~90%RH No condensing  (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Leakage Current Input—output: ≤0.25mA    Input—PG: ≤3.5mA (264Vac input, 63Hz) Isolation Resistance 10Mohms EMI Conduction&Radiation Compliance toEN55022, EN55024, FCC PART 15  Class B Harmonic Current Compliance toEN61000-3-2 Class D EMSImmunity Compliance toEN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs(25℃, Full load) Dimension (L*W*H) 208*60*30mm Packing 32pcs/CTN Cooling method Free air flow(PSU fixed to aluminum heat-sink of 400mm*400mm*2mm) NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 100uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. We cannot guarantee that the final equipment will meet EMC directives, Final product manufactures must be re-confirm that their product meets EMC directives. We provide high-quality LED power supplies for indoor and outdoor, and a variety of specifications and models of LED power supplies are optional, suitable for specific lighting applications in multiple fields.
  • VAT-UP200U-X
    VAT-UP200U-X
    Ø  Universal AC input Ø  Built-in active PFC,PF>0.95 Ø  High efficiency, long life and high reliability Ø  Output protection: SCP/OLP/OVP/OPP Ø  Wide operating ambient temperature (-20~65℃) Ø  All using105℃long life electrolytic capacitor Ø  100% full load burn-in test Ø  3 years warranty MODEL VAT-UP200U-5 OUTPUT DC Output 5.0V Rated Current 40A CurrentRange    Note 1 0~40A Peak load 45A (50mS, 220Vac input) Ripple and Noise  Note 2 0~65℃ ≤250mV -20℃ ≤300mV Voltage ADJ. Range / Voltage Accuracy ±4.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2S (220VAC input, 40A) Hold up Time ≥5mS (220Vac input, 32A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac FrequencyRange 47Hz--63Hz Power Factor(Typical) PF>0.95/230VAC   full load Efficiency ( Typical) ≥89%(220VAC, 40A)    ≥87%(110VAC, 30A) AC Current (max.) <2A Inrush Current (Typical) <60A@230Vac Cold start Leakage Current Input—output:<0.25mA    Input—PG:<3.5Ma (264Vac, 63Hz) PROTECTION Over Load 44~65A, Hiccup mode, auto recovery Over power 220~320W, hiccup mode, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -20℃~65℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing Vibration 10 ~ 500Hz,2G10min./1cycle, period for 60min. each along X,Y, Z axes Withstand Voltage Primary-Secondary: 3.0KVac; ≤10mA .Primary-PG: 1.5KVac; ≤10mA. Secondary-PG: 0.5KVDC; ≤10mA. Isolation Resistance 10Mohms SAFETY&EMC (Note 3) EMI Conduction & Radiation Compliance to EN55022, EN55024, FCC PART 15  CLASS B Harmonic Current Compliance to EN61000-3-2, Class D EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 100,000Hrs (25℃, Full load) Dimension (L*W*H) 210×31.5×30mm Packing 49PCS/CTN, 15KGS, 0.04CBM Cooling method Cooling by air NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttp://www.powerld.com.cn.
  • VAT-HP260-X-C
    VAT-HP260-X-C
    Ø  High voltage input (176~264Vac) Ø  With Active PFC, PF>0.95 Ø  Surge 300Vac for 60S Ø  High Efficiency, long life and High reliability Ø  Output protections: OCP/SCP/OPP/OTP Ø  Wide operating ambient temperature (-40℃~50℃) Ø  Operating altitude up to5000m Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Fanless, quiet working Ø  PCB with conformal coating Ø  Low profile, 30mm        Ø  3 years warranty MODEL VAT-HP260-5.2-C OUTPUT DC Output 5.2V Rated Current 40A Current Range     Note 1 0~50A Peak load 55A Ripple and Noise  Note 2 0~50℃ ≤150mV -40~0℃ ≤400mV Voltage Accuracy@-40~50C ±3% Line Regulation ±0.5% Load Regulation ±2% Set-up Time @25℃ ≤2S (220Vac input,40A) Hold up Time ≥5mS (220Vac input,32A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <±5% INPUT Voltage Range   Note 3 176~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) 92%  (220Vac input,40A) AC Current (max.) <3.5A Inrush Current (Typical) <60A@220Vac      Cold start Power Factor @25℃ >0.95  (input 220Vac,40A) Stand by power consumption <4W Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA   (input 264Vac, 63Hz) PROTECTION Over Current 55~80A , hiccup mode, auto recovery Over Power 286~416W, hiccup mode, auto recovery Over Temperature 115℃+5℃(detect on temperature protector);shut down, auto recovery after ambient temperature goes down to 50℃(temperature protector goes down to 85℃+15℃) Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~50℃;  20%~90%RH  No condensing(refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC   (Note 3) Safety Standards GB4943 / EN60950 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 10M ohms EMI Conduction&Radiation Compliance to EN55022, EN55024, FCC PART 15   CLASS B Harmonic current Compliance to EN61000-3-2, Class D EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) >200000h (25℃, Full load) Dimension  (L*W*H) 133*55*30mm Packing 49PCS/CTN, 15KGS, 0.04CBM Cooling method Cooling by free air convection NOTE 1.   All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.   Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • PSF-230S Medical power supply
    PSF-230S
    Ø Universal input 85~264Vac or 120~370Vdc Ø  Built-in Active PFC, PF>0.95 Ø  140W free air convection, 230W force air Ø  No load power consumption<0.3W Ø  Extremely low leakage current<0.1mA Ø  12V/0.5A fan supply Ø  Output protections: SCP/OVP/OCP/OTP Ø  Wide operating ambient temperature (-40℃~70℃) Ø  Operating altitude up to 5000m Ø  4.07’’*2’’ *1’’Compact size Ø  Suitable for BF applications Ø  Fit for Class I & Class II configuration        Ø 3 years warranty  MODEL PSF-230S-12 PSF-230S-24 PSF-230S-36 PSF-230S-48 OUTPUT DC Output 12V 24V 36V 48V Rated Current (free air convection) 11.7A (140.4W) 5.83A (139.92W) 3.9A (140.4W) 2.92A (140.16W) Rated Current (13CFM forced air) 19.2A (230.4W) 9.58A (229.92W) 6.39A (230.04W) 4.79A (229.92W) Ripple and Noise  Note 2 0~70℃ 100mV -40℃~0℃ 200mV Voltage ADJ.  Range 11.4~12.6V 22.8~25.2V 34.2~37.8V 45.6~50.4V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% ±0.5% Set-up Time ≤1.5S (230Vac input, Full load); ≤3.0S (115Vac input, full load) Hold up Time ≥12mS @115Vac input ;  ≥16mS @230Vac input   Full load Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT Voltage Range   Note 3 85~264Vac/120~370Vdc Rated input voltage range 100~240Vac Frequency Range 47Hz-63Hz Efficiency ( Typical) 93% 94% 94% 94% Power Factor(Typical) PF>0.99/115Vac, PF>0.95/230Vac  full load AC Current (max.) ≤3 A/115Vac   ≤1.5 A/230Vac  full load Inrush Current (Typical) 60A/230Vac      Cold start Leakage Current Input to PG: ≤0.25mA    Input to output: ≤0.1mA  PROTECTION Over Current 21.1~34.5A 10.5~17.2A 7~11.5A 5.27~8.62A Protection type: Hiccup mode, auto recovery Over Power 110%~180%, Hiccup mode, auto recovery Over Voltage ≤16V ≤32V ≤48V ≤60V Protection type: Re-power on Over temperature Shut down when temperature is too high; auto recovery when temperature is low Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~70℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing Operating altitude (Note 3) 5000 meters SAFETY &EMC   (Note 4) Safety Standards IEC62368 / IEC60601 Withstand Voltage Primary-Secondary: 4KVac/10mA; Primary to PG: 1.5KVac/10mA; Secondary-PG: 1.5Vac/10mA Isolation Resistance 50M ohms Isolation Level Input-output 2*MOPP Input-FG 1*MOPP Output-FG 1*MOPP EMI Conduction&Radiation Compliance to EN55032 Class B Harmonic Current Compliance to EN61000-3-2, Class D EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 103.5*50.8*25.4mm (4.07’’*2’’*1’’ inch) Packing TBD Cooling method 140W free air convection; 230W with 13CFM forced air NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.     The ambient temperature derating of 0.5℃/100m for operating altitude higher than 2000m. 4. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
  • PSF-550S industry power supply
    PSF-550S
    Ø  Universal input 80~264Vac or 113~370Vdc Ø  Built-in Active PFC, PF≥0.95 Ø  400W convention, 550W forced air Ø  No load power consumption<0.5W by PS­_ON/OFF Ø  Extremely low leakage current≤0.1mA Ø  12V/0.5A fan supply Ø  Output protections: SCP/OVP/OCP/OTP Ø  Wide operating ambient temperature (-40℃~70℃) Ø  Operating altitude up to 5000m Ø  5’’*3’’ Compact size Ø  Meet medical safety(2*MOPP) Ø  Fit for Class I & Class II configuration Ø  3 years warranty MODEL PSF-550S-12 PSF-550S-24 PSF-550S-36 PSF-550S-48 PSF-550S-54 OUTPUT DC Output 12V 24V 36V 48V 54V Rated Current (Convection) 33.4A 16.7A 11.1A 8.34A 7.4A Rated Current (16CFM forced air) 41.7A 22.9A 15.3A 11.46A 10.2A Rate Power(Convection) 400.8W 400.8W 399.6W 400.3W 399.6W Rate Power(16CFM forced air) 500.4W 549.6W 550.8W 550W 550.8W Ripple and Noise @25℃ Note 2 ≤200mVp-p Voltage ADJ.  Range 11.4~12.6V 22.8~25.2V 34.2~37.8V 45.6~50.4V 50.5~54V Voltage Accuracy ±2% Line Regulation ±1.0% Load Regulation ±1.0% Set-up Time ≤1.0S (230Vac input, Full load) Hold up Time 8mS @115/230Vac input   Full load Temperature Coefficient ±0.02%/℃ Overshoot <5.0% INPUT Voltage Range   Note 3 80~264Vac or 113~370Vdc Rated input voltage range 100~240Vac Frequency Range 47Hz-63Hz Efficiency ( Typical) 93.5% 94% 94% 94% 94% Power Factor(Typical) ≥0.95 @ 100~240Vac  full load AC Current (max.) <6.5A Inrush Current (Typical) <40A@115Vac ; <80A @ 230Vac      Cold start Leakage Current Touch current ≤0.1mA   @ ac input to dc output PROTECTION Over Current 110%~150%, hiccup mode, recovers automatically after fault condition is removed Over Voltage 110%~130%, constant voltage, recovers automatically after fault condition is removed Over temperature Shut down o/p voltage, recovers automatically after temperature goes down Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~70℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing Operating altitude (Note 3) 5000 meters SAFETY &EMC   (Note 4) Safety Standards IEC62368 / IEC60601 Withstand Voltage Primary-Secondary: 4KVac/5mA; Primary to PG: 2.0KVac/5mA; Secondary-PG: 1.5Vac/5mA Isolation Resistance 100M ohms EMI Conduction&Radiation Compliance to EN55032 Class B(Class I); Harmonic Current Compliance to EN61000-3-2, Class A EMS Immunity Compliance to EN61000-4-2,3,4,6,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃) 5V standby 5V/1A,tolerance ±2%, ripple : 120mVp-p(max.) PS_ON/OFF Power ON: PS-ON/OFF, "Hi" or " > 2 ~ 5V" ; Power OFF: PS-ON/OFF,"Low" or " < 0 ~ 0.5V" POWER GOOD / POWER FAIL 500ms>PG>10ms ; The TTL signal goes high with 10ms to 500ms delay after power set up ; The TTL signal goes low at least 1ms before Vo below 90% of rated value Dimension  (L*W*H) 127*76.2*40.5mm (5’’*3’’*1.59’’ inch) Packing TBD Cooling method 400W free air convection; 550W with 16CFM forced air NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.     The ambient temperature derating of 0.5℃/100m for operating altitude higher than 2000m. 4. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 
    A total of

    3

    pages
#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #