other
Search
Home Search
  • PDF-350-X power supply
    PDF-350-X
    Ø  Universal AC input (90~264Vac) Ø  Built-in active PFC,PF>0.95 Ø  No load power consumption<5W Ø  Withstand 300Vac surge input Ø  High efficiency up to 90% Ø  Output protection: SCP/OLP/OPP/OVP/OTP Ø  Wide operating ambient temperature (-30~70℃) Ø  Operating altitude up to5000m Ø  PCB soldering side with conformal coating Ø  All using105 ℃long life electrolytic capacitor Ø  100% full load burn-in test Ø  Cooling by free air convection Ø  3 years warranty SPECIFICATION                                                       MODEL PDF-350-12 PDF-350-24 PDF-350-48 OUTPUT DC Output 12V 24V 48V Rated Current 25A 14.6A 7.3A CurrentRange    Note 1 0~25A 0~14.6A 0~7.3A Peak Load 30A(last 60S, 230Vac input) 18A(last 60S, 230Vac input) 9A(last 60S, 230Vac input) Ripple and Noise  Note 2 0~70℃ ≤150mV ≤240mV ≤240mV -30℃ ≤240mV ≤480mV ≤480mV Voltage ADJ. Range 11.6~13.2V 23.5~26.5V 47~52.8V Voltage Accuracy ±3.0% Line Regulation ±1.0% Load Regulation ±2.0% Set-up Time ≤3S (230Vac input, Full load) Hold up Time ≥10mS (230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac FrequencyRange 47Hz--63Hz Power Factor(Typical) PF>0.98/115VAC   PF>0.95/230VAC Efficiency ( Typical) ≥90% (230Vac input, full load) ≥90% (230Vac input, full load) ≥93% (230Vac input, full load) AC Current (max.) <5.0A Inrush Current (Typical) <40A@230Vac  <20A@115Vac  Cold start Stand by power consumption <5W Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA PROTECTION Over Load 26.3~37.5A, constant current 15.33~21.9A, constant current 7.7~11A, constant current Over Power 315~450W, constant current 368~525W, constant current 368~525W, constant current Over Voltage 13.8~16.0V 26.5~36V 50~63V Constant voltage, auto recovery Over Temperature 95℃±5℃(detect on temperature controller) shut down o/p voltage, auto recovery after temperature goes down to50C Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -30℃~70℃; 20%~90%RH No condensing(refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 3) Safety Standards UL60950-1 ;EN60950-1:2006 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 10Mohms EMI Conduction & Radiation Compliance to EN55022,FCC PART 15 Class B Harmonic current Compliance to EN61000-3-2,CLASS D EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 199×99×50mm Packing 12PCS/CTN, 13.5KGS, 0.04CBM Cooling method Free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com
  • PD-35-X Power Supply
    PD-35-X
    Ø  No Load power consumption<0.5W Ø  Universal AC input range Ø  Miniature size, high power density, high efficiency, long life and high reliability Ø  Withstand 300VA surge input for 5 sec. Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temp (-25℃~70℃),100% @50℃& 60%@70℃ Ø  Operating altitude up to 5000M Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Easy assembling from top side Ø  PCB soldering side with conformal coating Ø  Suitable for critical applications Ø  3 years warranty    SPECIFICATION                                              MODEL PD-35-5 PD-35-12 PD-35-15 PD-35-24 PD-35-48 OUTPUT DC Output 5V 12V 15V 24V 48V Rated Current 6A 3A 2.4A 1.5A 0.76A Current Range      0~6A 0~3A 0~2.4A 0~1.5A 0~0.76A Ripple and Noise   Note 2 0~70℃ <50mV <80mV <120mV <120mV <180 mV -25~0℃ <80mV <180mV <200mV <200mV <240mV Voltage ADJ.  Range 4.75V-5.5V 11.4V-13.2V 14.25V-16.5V 22.8V-26.4V 45.6V-52.8V Voltage Accuracy ±3.0% ±3.0% ±3.0% ±3.0% ±3.0% Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% Load Regulation ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% Set-up Time <1S (230Vac input, Full load); Hold up Time >20mS(230Vac input, Full load); >10mS(120Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   90Vac~264Vac,127~370Vdc Frequency Range 47Hz~63Hz Efficiency ( Typical) 115Vac input 79% 83% 85% 86% 87% 230Vac input 80% 84% 86% 87% 88% AC Current (max.) <1A(max) Inrush Current (Typical) <50A@230Vac     Cold start Leakage Current Input—output:<3.5mA     Input—PG:<0.25mA PROTECTION Over Load 105%~150% of rated output current, constant power,auto recovery Over Voltage 105%~150% of rated output voltage, Constant Voltage Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100M ohms EMC Emission Compliance to EN55022,EN55024 ClassB Harmonic Current Compliance to EN61000-3-2,-3 EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11;EN55024,EN61000-6-2 heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 101.6×63.5×33mm Packing 60PCS/CTN, 15.18KGS, 0.06CBM Cooling method Cooling by free air convection NOTE 1.     All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.        The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. 4.        Powerld offer accessories for Din-35 rail bar. Please contact sales staff for details. Quality industrial power supply products, excellent service, hope to establish the long-term business relationship with you.
  • LPD-50-X Power Supply
    LPD-50-S
    Ø  No Load power consumption≤0.3W Ø  Universal AC input range (90~264Vac) Ø  Withstand 300Vac surge input for 5 sec. Ø  High efficiency, long life and high reliability Ø  Efficiency up to 90% Ø  Output protections: OCP/OVP/OPP/SCP Ø  Wide operating ambient temp (-30℃~70℃) Ø  Operating altitude up to 5000m Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  3 years warranty      MODEL LPD-50-S5 LPD-50-S12 LPD-50-S15 LPD-50-S24 LPD-50-S36 LPD-50-S48 OUTPUT DC Output 5V 12V 15V 24V 36V 48V Rated Current 10A 4.2A 3.4A 2.2 1.45A 1.1A Current Range      0~10A 0~4.2A 0~3.4A 0~2.2A 0~1.45A 0~1.1A Rated Power 50W 50.4W 51W 52.8W 52.2W 52.8W Ripple and Noise   note2 0~70℃ 80mV 120mV 120mV 200mV 200mV 200mV -30~0℃ 120mV 300mV 360mV 360mV 360mV 500mV Voltage ADJ.  Range 4.5~5.5V 10.8~13.2V 13.5~16.5V 21.6~26.4V 32.4~39.6V 43.2~52.8V Voltage Accuracy ±3.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time ≤1S (230Vac input, Full load) Hold up Time ≥30mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT Voltage Range   90Vac~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) 83% 86% 85% 88% 89% 90% AC Current (max.) <1.0A @ 115Vac Inrush Current (Typical) 60A@230Vac      Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Current 11~18A 4.62~7.5A 3.74~6A 2.42~3.75A 1.6~2.5A 1.21~1.875A Protection type: hiccup mode, auto recovery Over power 55~90W 55.5~90W 56.1~90W 58~90W 57.4~90W 58~90W Protection type: hiccup mode, auto recovery Over Voltage 5.75~6.9V 13.8~16.2V 18.75~21.75V 28.8~33.6V 41.4~48.6V 55.2~64.8V Protection type: hiccup mode, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Amb. Temp. & Hum. -30℃~70℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards GB4943/IEC62368  EN60335-1, EN61558-1/-2-16,CCC GB4943 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance 100M ohms EMC Emission Compliance to EN55032 Class B(Note 3) EMC Immunity Compliance to EN61000-4-2, 3, 4, 5, 6, 11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 99*82*30mm Packing 36pcs/CTN Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. Power supply is installed on a baseplate of 360*360*1mm for EMC test.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • PWF-150L-X Power Supply
    PWF-150L-X
    Ø  Universal AC input range(85~264Vac) Ø  Built-in Active PFC function, PF>0.95 Ø  Miniature size, high power density, high efficiency, long life and high reliability Ø  Output protections: OLP/SCP/OPP Ø  Wide operating ambient temp (-20℃~65℃) Ø  Operating altitude up to5000M Ø  100% full load burn-in test Ø  Easy assembling from top side Ø  PCB soldering side with conformal coating Ø  Suitable for critical applications Ø  3 years warranty       SPECIFICATION                                              MODEL PWF-150L-12 PWF-150L-24 PWF-150L-27.6 PWF-100L-48 OUTPUT DC Output 12V 24V 27.6V 48V Rated Current 12.5A 6.3A 5.4A 3.2A CurrentRange    Note 1 0~12.5A 0~6.3A 0~5.4A 0~3.2A Ripple and Noise  Note 2 0~65℃ ≤100mV ≤150mV ≤240mV ≤240mV -20~0℃ ≤200mV ≤300mV ≤480mV ≤480mV Voltage ADJ. Range ±10% of rated output voltage Voltage Accuracy ±1.0% ±1.0% ±1.0% ±1.0% Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% Load Regulation ±1.0% ±0.5% ±1.0% ±0.5% Set-up Time ≤2S (230VAC input, Full load) ; ≤4S (115VAC input, Full load) Hold up Time ≥15mS(115 / 230VAC , FULL LOAD) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   85Vac~264Vac FrequencyRange 47Hz~63Hz Power factor (typical) PF>0.98/115VAC  PF>0.95/230VAC    full load Efficiency (Typical)230Vac input ≥86% ≥86% ≥86% ≥87% Efficiency (Typical)120Vac input ≥83% ≥83% ≥83% ≥84% AC Current (max.) 1.7A/115Vac 0.8A/230Vac Inrush Current (Typical) <50A@230VAC Cold start & <30A@115VAC    Cold start Leakage Current Input—output: ≤0.25mA   Input—PG: ≤3.5mA PROTECTION Over Load 105%~150% of rated output current, hiccup mode, auto recovery Over power 105%~150% of rated output current, hiccup mode, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -20℃~65℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -20℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1 2ndEd; IEC 60950-1:2005(2ndEd) ;EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance 100Mohms EMSEmission Compliance to EN55022, EN55024, FCC PART 15 CLASS B Harmonic Current Compliance to EN61000-3-2, Class D EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 199×99×38mm Packing 20PCS/CTN, 15KGS, 0.04CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com Powerld enterprises is specialized in switching power supply since 1991, obtained ISO9001 certificate in 2002, ISO14001 certificate in 2006.As a professional switching power supply manufacturer,Powerld can supply a broad range of power supply,we can not only supply our customers with high quality products,but also our best service and fast delivery time.
  • VAT-UP200U-X
    VAT-UP200U-X
    Ø  Universal AC input Ø  Built-in active PFC,PF>0.95 Ø  High efficiency, long life and high reliability Ø  Output protection: SCP/OLP/OVP/OPP Ø  Wide operating ambient temperature (-20~65℃) Ø  All using105℃long life electrolytic capacitor Ø  100% full load burn-in test Ø  3 years warranty MODEL VAT-UP200U-5 OUTPUT DC Output 5.0V Rated Current 40A CurrentRange    Note 1 0~40A Peak load 45A (50mS, 220Vac input) Ripple and Noise  Note 2 0~65℃ ≤250mV -20℃ ≤300mV Voltage ADJ. Range / Voltage Accuracy ±4.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2S (220VAC input, 40A) Hold up Time ≥5mS (220Vac input, 32A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac FrequencyRange 47Hz--63Hz Power Factor(Typical) PF>0.95/230VAC   full load Efficiency ( Typical) ≥89%(220VAC, 40A)    ≥87%(110VAC, 30A) AC Current (max.) <2A Inrush Current (Typical) <60A@230Vac Cold start Leakage Current Input—output:<0.25mA    Input—PG:<3.5Ma (264Vac, 63Hz) PROTECTION Over Load 44~65A, Hiccup mode, auto recovery Over power 220~320W, hiccup mode, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -20℃~65℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing Vibration 10 ~ 500Hz,2G10min./1cycle, period for 60min. each along X,Y, Z axes Withstand Voltage Primary-Secondary: 3.0KVac; ≤10mA .Primary-PG: 1.5KVac; ≤10mA. Secondary-PG: 0.5KVDC; ≤10mA. Isolation Resistance 10Mohms SAFETY&EMC (Note 3) EMI Conduction & Radiation Compliance to EN55022, EN55024, FCC PART 15  CLASS B Harmonic Current Compliance to EN61000-3-2, Class D EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 100,000Hrs (25℃, Full load) Dimension (L*W*H) 210×31.5×30mm Packing 49PCS/CTN, 15KGS, 0.04CBM Cooling method Cooling by air NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttp://www.powerld.com.cn.
    A total of

    1

    pages
#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #