  • DG-120-X  din rail power supply
    DG-120-X
    Ø  Universal AC input range(85~264Vac) Ø  Support 1+1 or N+1 redundant system(suggest to use redundancy modules.) Ø  Built-in active PFC,PF>0.95 Ø  High efficiency up to 92% Ø  Built-in current sharing function Ø  Built-in current limiting circuit Ø  Output protections: OVP/OLP/SCP/OTP Ø  Wide operating ambient temp (-25℃~70℃) Ø  150%(180W) peak load capacity Ø  Easy Fuse Tripping due to High Overload Current Ø  Excellent Partial Load Efficiency Ø  Built-in DC OK relay contact Ø  Can be installed on TS-35/7.5 or TS-35/15 Ø  100% full load burn-in test Ø  Suitable for critical applications Ø  Ultra-slim,32mm width Ø  3 years warranty SPECIFICATION MODEL DG-120-12 DG-120-24 DG-120-48 OUTPUT DC Output 12V 24V 48V Rated Current 10A(pls refer to derating curve) 5A 2.5A CurrentRange Note  0~10A 0~5A 0~2.5 Ripple and Noise  Note 2 0~70℃ ≤100mV ≤120mV ≤240mV -25℃ ≤200mV ≤240mV ≤240mV Voltage ADJ. Range 12~14V 24~28V 48~56V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <250mS@230Vac ; <500mS@100Vac Hold up Time ≥20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   85Vac~264Vac, 127Vdc-360Vdc FrequencyRange 47Hz~63Hz Power Factor (typical) 0.99/100Vac    0.95/230Vac Efficiency ( Typical) 89.5% 91% 92% AC Current (max.) <1.5 A/100Vac       <0.65A/230Vac Inrush Current (Typical) <30A/100Vac     <60A/230Vac  Cold start Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA PROTECTION Over Load 110%~150% of rated current, Constant current limiting for some time(150% of rated current, last 3S) then PS stop working for 7S,after 7S,if the load <=rated current, PS will work normally, auto recovery Over voltage 15~18V 29~33V 58~65V Protection type: Hiccup mode, Auto recovery Over temperature 100±5℃, detect on heat sink of power transistor; shut down O/P, auto recovery after temperature goes down. Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 5%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards meet UL508, UL60950, EN60950 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:2.5KVac;≤10mA. Secondary-PG:0.5KVac≤10mA. Isolation Resistance 10M ohms EMC Emission Compliance to EN55022, EN55024, FCC PART 15 Class B Harmonic Current Compliance to EN61000-3-2, CLASS A EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 300,000Hrs (25℃, Full load) Dimension (L*W*H) 124*119*32mm Packing 28pcs/CTN,18.02Kgs, 0.04cbm Cooling method Cooling by free air convection Additional function Power boost 150% of rated current DC OK V On: when output voltage is up to 90% of rated output voltage V Off: when output voltage is down to 80% of rated output voltage DC OK relay contact rating Max 30V/1Aor 60V/0.3Aor 30Vac/0.3AResistive load Parallel function support NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com. We have a complete DIN rail power supply product catalog, providing reliable quality DIN rail power supply and affordable prices, fast delivery, customizable, please leave a message for consultation.
  • PSF-200-X power supply
    PSF-200-X
    Ø  Universal AC input/ Full range Ø  Built-in Active PFC function Ø  Withstand 300Vac surge input for 5 sec. Ø  High efficiency up to 90%(typ) Ø  Output protections: OLP/OVP/SCP/OPP Ø  Wide operating ambient temperature (-20℃~70℃) Ø  All using105℃long life electrolytic capacitors. Ø  Free air convection for 150W and 200W with 20.5CFM forced air Ø  100% full load burn-in test Ø 5’’*3’’ compact size Ø  3 years warranty MODEL PSF-200-12 GZM-H25S12II PSF-200-24 PSF-200-27 PSF-200-48 OUTPUT DC Output 12V 8.5V 12V 12V 24V 27V 48V Rated Current 16.6A 3A 10.5A 2 A 8.4A 7.4A 4.167A CurrentRange(convection)    0~12.5A 0~3A 0~10.5A 0~2A 0~6.25A 0~5.5A 0~3.13A CurrentRange(20.5CFM fan) 0~16.6A 0~8.4A 0~7.4A 0~4.167A Ripple and Noise Note 20<Ta≤70℃ 0<Ta≤70℃ 120mVp-p 85mV 100mV 120mV 200 mVp-p 100 mVp-p 120 mVp-p -20≤Ta≤0℃ 200 mVp-p 200 mVp-p 150 mVp-p 240 mVp-p Voltage ADJ. Range ±10% of rated output voltage Voltage Accuracy ±1.0% ±3.0% ±5.0% ±2.0% ±2.0% Line Regulation ±0.5% ±0.5% ±1.0% ±0.5% ±0.5% Load Regulation ±1.0% ±2.0% ±1.0% ±2.0% ±2.0% Set-up Time ≤2S (230VAC input, Full load)& ≤4S (115VAC input, Full load) Hold up Time ≥16mS/150W 10mS/200W(115 / 230VAC IN AT FULL LOAD) Temperature Coefficient ±0.03%/℃ Overshootand Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac,127Vdc~370Vdc FrequencyRange 47Hz--63Hz Power Factor(Typical) PF>0.98/115VAC   PF>0.95/230VAC Efficiency ( Typical) ≥89% ≥89% ≥89% ≥90% AC Current (max.) <3A 2.5A 1.5A 0.3A 1.5A 1.5A 1.5A 1.5A Inrush Current (Typical) <50A@230Vac  <30A@115Vac  Cold start Leakage Current ≤3.5mA PROTECTION Over Current 105%~150% of rated output current, hiccup mode, auto recovery Over Power 105%~150% of rated output current, hiccup mode, auto recovery Over Voltage 125%~150% of rated output voltage, hiccup mode, auto recovery Short Circuit Long-term, Auto recovery ENVIRONMENT OperatingambTemp& Hum -20℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   Note 3 Safety Standards UL60950-1; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA .Secondary-PG:0.5KVDC;≤10mA . Isolation Resistance 100M ohms EMI Conduction&Radiation Compliance to EN55022,EN55024 ClassB Harmonic Current Compliance to EN61000-3-2,-3 EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11;EN55024,EN61000-6-2heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 128×76.5×34.6mm(5’’*3’’) Packing 21PCS/CTN, 8.46KGS, 0.015CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. We focus on your industrial power supply project needs, Offering reliable quality and high cost-effective products is always our top priority. Effective Communication within 24 hours.
  • DG-240-X power supply
    DG-240-X
    Ø  Universal AC input range(85~264Vac) Ø  Support 1+1 or N+1 redundant system(suggest to use redundancy modules.) Ø  Built-in active PFC,PF>0.95 Ø  High efficiency up to 94% Ø  Built-in current sharing function Ø  Built-in current limiting circuit Ø  Output protections: OVP/OLP/SCP/OTP Ø  Wide operating ambient temp (-25℃~70℃) Ø  150%(360W) peak load capacity Ø  Easy Fuse Tripping due to High Overload Current Ø  Excellent Partial Load Efficiency Ø  Built-in DC OK relay contact Ø  Can be installed on TS-35/7.5 or TS-35/15 Ø  100% full load burn-in test Ø  Suitable for critical applications Ø  Ultra-slim, 45mm width Ø  3 years warranty SPECIFICATION                                                MODEL DG-240-24 ABS-75-12 DG-240-48 OUTPUT DC Output 24V 12V 48V Rated Current 10A 6A 5A Current Range     Note 1 0~10A 0~6A 0~5A Ripple and Noise  Note 2 0~70℃ ≤240mV ≤480mV -25℃ ≤480mV ≤480mV Voltage ADJ.  Range 24~28V 48~56V Voltage Accuracy ±3.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <3S@230Vac  Hold up Time ≥20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   85Vac~264Vac, 127Vdc-375Vdc Frequency Range 47Hz~63Hz Power Factor (typical) 0.99/110Vac     0.95/230Vac Efficiency ( Typical) 94% ≥84% 93% ≥88% AC Current (max.) <3.0 A/100Vac        <1.5A/230Vac Inrush Current (Typical) <20A/110Vac      <40A/230Vac   Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Load 110%~150% of rated current, Constant current limiting for some time(150% of rated current, last 3S) then PS stop working for 7S,after 7S,if the load <=rated current, PS will work normally, auto recovery Over voltage 29~33V, constant voltage, Auto recovery 58~63V, constant voltage, Auto recovery Over temperature 105±5℃, detect on heat sink of power transistor; shut down O/P, auto recovery after temperature goes down. Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃;  20%~90%RH  No condensing Storage Temp. & Hum. -40℃~85℃;  5%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards meet UL508, UL60950, EN60950 Withstand Voltage Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:2.5KVac; ≤10mA. Secondary-PG:0.5KVac≤20mA. Isolation Resistance ≥100M ohms EMC Emission Compliance to EN55022, EN55024, FCC PART 15 Class B Harmonic Current Compliance to EN61000-3-2, CLASS A EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 300,000Hrs (25℃, Full load) Dimension  (L*W*H) 45*124*119mm Packing 24pcs/CTN, 21Kgs/CTN, 0.045cbm Cooling method Cooling by free air convection Additional function Power boost 150% of rated current Parallel function support DC-OK V On: when output voltage is up to 90% of rated output voltage V Off: when output voltage is down to 80% of rated output voltage DC-OK relay contact rating Max 30V/1A or 60V/0.3A or 30Vac/0.3A Resistive load NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • PD-75-X Power Supply
    PD-75-X
    Ø  No Load power consumption<0.5W Ø  Withstand 300VA surge input for 5 sec. Ø  High Efficiency, High reliability and long life Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temperature (-25℃~70℃) Ø  Operating altitude up to5000m Ø  All using105℃long life electrolytic capacitors. Ø  PCB soldering side with conformal coating Ø  100% full load burn-in test Ø  3 years warranty      SPECIFICATION                                              MODEL PD-75-5 PD-75-12 PD-75-15 PD-75-24 PD-75-48 OUTPUT DC Output 5V 12V 15V 24V 48V Rated Current 12A 6A 5A 3.2.A 1.6A Current Range     Note 1 0~12A 0~6A 0~5A 0~3.2A 0~1.6A Ripple and Noise Note 2 0~70℃ <50mV <80mV <80mV <80mV <120mV -25~0℃ <80mV <200mV <200mV <200mV <240mV Voltage ADJ.  Range 4.75~5.5V 11.4~13.2V 14.25~16.5V 22.8~26.4V 45.6~52.8V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time ≤1S(230Vac input, Full load) Hold up Time ≥20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   90Vac~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) 79% 84% 86% 86.5% 88% AC Current (max.) <2.5A Inrush Current (Typical) <60A@230Vac      Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA         (264Vac input, 63Hz) PROTECTION Over Load 12.6~18A 6.3~9A 5.25~7.5A 3.36~4.8A 1.7~2.43A Protection type: 5V, hiccup mode; others, constant power, Auto recovery Over Voltage 5.5~7.5V 13.2~18V 16.5~22.5V 26.4~36V 52.8~72V Protection type: constant voltage, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃;  20%~90%RH  No condensing((refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac/ 10mA .Primary-PG:1.5KVac/ 10mA. Secondary-PG:0.5KVDC/ 10mA. Isolation Resistance 100M ohms EMI Conduction& Radiation Compliance to EN55022 Class B / FCC Part15 B Harmonic Current Compliance to EN61000-3-2, Class A EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 129×98×38mm Packing 30PCS/CTN, 14.2KGS, 0.044CBM Cooling method Cooling by free air convection NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.        The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. 4.  Powerld offer accessories for Din-35 rail bar. Please contact sales staff for details. We always can deliver high-end quality industrial power supply products to our customers on time.Quality products,excellent service,we also welcome OEM and ODM industrial power supply orders.
  • LPD-50-X Power Supply
    LPD-50-S
    Ø  No Load power consumption≤0.3W Ø  Universal AC input range (90~264Vac) Ø  Withstand 300Vac surge input for 5 sec. Ø  High efficiency, long life and high reliability Ø  Efficiency up to 90% Ø  Output protections: OCP/OVP/OPP/SCP Ø  Wide operating ambient temp (-30℃~70℃) Ø  Operating altitude up to 5000m Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  3 years warranty      MODEL LPD-50-S5 LPD-50-S12 LPD-50-S15 LPD-50-S24 LPD-50-S36 LPD-50-S48 OUTPUT DC Output 5V 12V 15V 24V 36V 48V Rated Current 10A 4.2A 3.4A 2.2 1.45A 1.1A Current Range      0~10A 0~4.2A 0~3.4A 0~2.2A 0~1.45A 0~1.1A Rated Power 50W 50.4W 51W 52.8W 52.2W 52.8W Ripple and Noise   note2 0~70℃ 80mV 120mV 120mV 200mV 200mV 200mV -30~0℃ 120mV 300mV 360mV 360mV 360mV 500mV Voltage ADJ.  Range 4.5~5.5V 10.8~13.2V 13.5~16.5V 21.6~26.4V 32.4~39.6V 43.2~52.8V Voltage Accuracy ±3.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time ≤1S (230Vac input, Full load) Hold up Time ≥30mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT Voltage Range   90Vac~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) 83% 86% 85% 88% 89% 90% AC Current (max.) <1.0A @ 115Vac Inrush Current (Typical) 60A@230Vac      Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Current 11~18A 4.62~7.5A 3.74~6A 2.42~3.75A 1.6~2.5A 1.21~1.875A Protection type: hiccup mode, auto recovery Over power 55~90W 55.5~90W 56.1~90W 58~90W 57.4~90W 58~90W Protection type: hiccup mode, auto recovery Over Voltage 5.75~6.9V 13.8~16.2V 18.75~21.75V 28.8~33.6V 41.4~48.6V 55.2~64.8V Protection type: hiccup mode, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Amb. Temp. & Hum. -30℃~70℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards GB4943/IEC62368  EN60335-1, EN61558-1/-2-16,CCC GB4943 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance 100M ohms EMC Emission Compliance to EN55032 Class B(Note 3) EMC Immunity Compliance to EN61000-4-2, 3, 4, 5, 6, 11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 99*82*30mm Packing 36pcs/CTN Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. Power supply is installed on a baseplate of 360*360*1mm for EMC test.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • LPD-100-X Power Supply
    LPD-100-X
    Ø        Universal AC input: 90~ 264Vac Ø        Can bear 300Vac for 5s Ø        No load power consumption<0.5W Ø        High efficiency, long life and high reliability Ø        Output protections: OCP/OVP/SCP Ø        Wide operating ambient temperature (-30℃~70℃) Ø        Altitude up to 5000m Ø        All using 105℃ long life electrolytic capacitors. Ø        100% full load burn-in test Ø        1 U low profile Ø        3 years warranty MODEL LPD-100-5 LPD-100-12 LPD-100-15 LPD-100-24 LPD-100-36 LPD-100-48 OUTPUT DC Output 5V 12V 15V 24V 36V 48V Rated Current 18A 8.5A 7A 4.5A 3A 2.3A Current Range 0~18A 0~8.5A 0~7A 0~4.5A 0~3A 0~2.3A Rated Power 90W 102W 105W 108W 108W 110.4W Ripple and Noise (note1) 120 mV 150mV 150mV 200mV 200mV 200mV Voltage ADJ.  Range 4.5~5.5V 10.8~13.2V 13.5~16.5V 21.6~26.4V 32.4~39.6V 43.2~52.8V Voltage Accuracy ±30% ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time ≤500mS  (230Vac/115Vac, Full load) Hold up Time ≥20mS(230Vac, Full load)  ≥10mS(115Vac, Full load) Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT Voltage Range   Note 3 90Vac~264Vac Frequency Range 47Hz-63Hz Efficiency ( Typical) 230Vac input 86% 87% 88 % 90% 90.5% 91% AC Current (max.) <1.9A@115Vac  <1.2A@230Vac Inrush Current (Typical) <65A@230Vac      Cold start PROTECTION Over Power 110%~180% rated power, hiccup mode, auto recovery Over Current 110%~160% of rated current, hiccup mode, auto recovery Over Voltage 5.75~6.9V 13.8~16.2V 18.75~21.75V 28.8~33.6V 41.4~48.6V 55.2~64.8V Protection type: Constant voltage, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -30℃~70℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC   (Note 4) Safety Standards UL62368-1, IEC/EN62368-1 Withstand Voltage Primary-Secondary:3..0KVac/10mA.; Primary-PE:1.5KVac/10mA; Secondary-PE:0.5KVdc/10mA . Leakage Current Input—output:<0.25mA     Input—PE:<0.75mA  (@240Vac/63Hz) Isolation Resistance 100M ohms EMI Conduction&Radiation Compliance to EN55032 Class B Harmonic Current Compliance to EN61000-3-2,CLASS A EMS Immunity Compliance to EN61000-4-2,3,4,6,8,11 OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 129*97*30mm Packing 30pcs/CTN Cooling method Cooling by free air flow NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • LPD-150-X Power Supply
    LPD-150-X
    Ø  Universal AC input (90~264Vac) Ø  No load power consumption < 0.5W Ø  High efficiency, long life and high reliability Ø  Withstand 300Vac surge input for 5s Ø  Output protections: OLP/SCP/OVP/OPP Ø  Wide operating ambient temp (-30℃~70℃) Ø  Altitude up to 5000m Ø  All using 105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  1U low profile Ø  3 years warranty MODEL LPD-150-12 LPD-150-15 LPD-150-24 LPD-150-36 LPD-150-48 OUTPUT DC Output 12V 15V 24V 36V 48V Rated Current 12.5A 10A 6.25A 4.17A 3.125A Current Range     Note 1 0~12.5A 0~10A 0~6.25A 0~4.17A 0~3.125A Rated Power 150W 150W 150W 150W 150W Ripple and Noise @25C Note 2 150mV 150mV 200mV 200mV 200mV Voltage ADJ.  Range 10.8~13.2V 13.5~16.5V 21.6~26.4V 32.4~39.6V 43.2~52.8V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±0.5% Set-up Time ≤600ms/30ms (230Vac/115Vac input, Full load) Hold up Time ≥20mS(230Vac input, Full load)     Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT Voltage Range   90~264Vac  120-370VDC Frequency Range 47Hz~63Hz Efficiency ( Typical) @230Vac 84% 86% 88% 88% 89% AC Current (max.) ≤3A(115Vac)  /  ≤1.7A(230Vac) Inrush Current (Typical) ≤40A@220Vac   Cold start Leakage Current Input—output:<0.25mA ; Input—PG:<0.75mA   (Input 240Vac, 63Hz) PROTECTION Over current 120%~180% of rated current, Hiccup mode, auto recovery Over power 120%~180% of rated power, Hiccup mode, auto recovery Over voltage 120%~150% of rated output voltage, constant voltage, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -30℃~70℃;  20%~90%RH  No condensing Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards UL62368-1, IEC/EN62368-1 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance 100M ohms EMC Emission Compliance to EN55032 Class B EMC Immunity Compliance to EN61000-4-2,3,4,6,8,11 OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 159*97*30mm Packing 20pcs/CTN Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • LPD-200-X Power Supply
    LPD-200-X
    Ø  AC input selectable by switch (115Vac/230Vac) Ø  High efficiency, long life and high reliability Ø  Output protections: OLP/SCP/OVP/OPP Ø  Wide operating ambient temp (-25℃~70℃) Ø  100% full load burn-in test Ø  Altitude up to 5000m Ø  1U low profile Ø  Cooling by free air convection Ø  3 years warranty MODEL LPD-200-12 LPD-200-24 LPD-200-36 LPD-200-48 OUTPUT DC Output 12V 24V 36V 48V Rated Current 16.67A 8.33A 5.56A 4.17A Current Range     Note 1 0~16.67A 0~8.33A 0~5.56A 0~4.17A Rated Power 200W 200W 200W 200W Ripple and Noise  Note 2 0~70℃ ≤150mV ≤150mV ≤200mV ≤200mV -25℃ ≤300mV ≤300mV ≤400mV ≤400mV Voltage ADJ.  Range 10.2~13.8V 21.6~28.8V 32.4~39.6V 43.2~52.8V Voltage Accuracy ±1.5% ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% ±0.5% Set-up Time ≤2.0S/50mS (230/115Vac input, Full load) Hold up Time ≥16mS(230Vac input, Full load)    ≥12mS(115Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT Voltage Range   90Vac~132Vac/180Vac~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) @230Vac ≥86.5% ≥88.5% ≥89% ≥89.5% AC Current (max.) <4.0 A@ 115Vac   ;   <2.2A @ 230Vac 2.5A Inrush Current (Typical) <60A@ 115/230Vac   Cold start Leakage Current Input—output:<0.25mA ; Input—PG:<2.0mA   (Input 240Vac) PROTECTION Over current 18.33~30.0A 9.17~15.0A 6.11~10A 4.58~7.5A Protection type: Hiccup mode, auto recovery Over power 220~360W 220~360W 220~360W 220~360W Protection type: Hiccup mode, auto recovery Over voltage 13.8~16.2V 28.8~33.6V 41.4~46.8V 55.2~64.8V Protection type: Constant voltage, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃;  20%~90%RH  No condensing Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards UL62368-1, IEC/EN62368-1 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:2.0KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance 10M ohms EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11 OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 190*99*30mm Packing 20pcs/CTN Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • LPD-350-X Power Supply
    LPD-350-X
    Ø  AC input selectable by switch (115Vac/230Vac) Ø  High efficiency, long life and high reliability Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temp (-25℃~70℃) Ø  Altitude up to 5000m Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  3 years warranty SPECIFICATION MODEL LPD-350-12 LPD-350-24 OUTPUT DC Output 12V 24V Rated Current 29.17A 14.58A Current Range     0~29.17A 0~14.58A Ripple and Noise  Note 2 0~70℃ ≤150mV ≤150mV -25℃ ≤300mV ≤300mV Voltage ADJ. Range 10.2~13.8V 21.6~28.8V Voltage Accuracy ±1.5% ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% ±0.5% Set-up Time ≤2.3S Full load Hold up Time ≥12mS/115Vac input, Full load; ≥16mS/230Vac input, Full load Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT VoltageRange   90Vac~132Vac/180Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency @230Vac input ≥85% ≥87% AC Current (max.) <6.8A/115Vac ; <3.4A/230Vac 2.5A Inrush Current ﹤60A@ 115Vac/230Vac  Cold start Leakage Current Input—output:<0.25mA    Input—PG:<2.0mA (Input 240Vac) PROTECTION Over Load 30.63~43.75A 15.31~21.88A Protection type: Hiccup mode, auto recovery Over Power 367.5~525W 367.5~525W Protection type: Hiccup mode, auto recovery Over voltage 13.8~16.2V 28.8~33.6V Protection type: Constant voltage, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards GB4943 / EN60950 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:2.0KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance 10M ohms EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 190*99*30mm Packing TBD Cooling method Cooling by forced air (Built-in DC fan) NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com