other
Search
Home Search
  • VAT-UP200-X-P-A power supply
    VAT-UP200-X-P-A
    Ø  Universal AC input (90~264Vac) Ø  With Active PFC, PF>0.95 Ø  Surge 300Vac for 60S Ø  High Efficiency, long life and High reliability Ø  Output protections: OLP/OVP/SCP/OPP Ø  1+1 parallel function, current sharing Ø  Wide operating ambient temperature (-40℃~65℃) Ø  Operating altitude up to5000m Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Fanless, quiet working Ø  PCB with conformal coating Ø  Low profile, 30mm Ø  3 years warranty MODEL VAT-UP200-4.2-P-A VAT-UP200-5-P-A OUTPUT DC Output 4.2V 5V Rated Current 40A 40A CurrentRange    Note 1 0~40A 0~40A Peak load 50A(50mS, 220Vac input) Ripple and Noise  Note 2 0~65℃ ≤150MV ≤200MV Voltage Accuracy@-40~65C 4.15~4.4V ±3% Line Regulation/ ±0.5% Load Regulation ±2% Set-up Time @25℃ ≤2S (220Vac input,40A) Hold up Time ≥5mS (220Vac input,32A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% Parallel (current sharing) Current-unbalance< 10% (single PS drive40Aload, the voltage of current share bus is 2.9~4V) INPUT VoltageRange  Note 3 90Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 86% (220Vac input,40A) 88% (220Vac input,40A) AC Current (max.) <3.5A Inrush Current (Typical) <60A@220Vac     Cold start Power Factor @25℃ >0.95 (input 220Vac,40A) Stand by power consumption <4W (input 220Vac) Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA  (input 264Vac, 63Hz) PROTECTION Over Load 44~65A, hiccup mode, auto recovery 44~65A, hiccup mode, auto recovery Over Power 184.8~252W, hiccup mode, auto recovery 220~325W, hiccup mode, auto recovery Over Voltage 4.5~6.5V, hiccup mode, auto recovery 5.2~6.5V, constant voltage Over Temperature 105℃+5℃(detect on temperature controller);shut down, auto recovery after the temperature goes down to65℃ Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~65℃; 20%~90%RH No condensing(refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 4) Safety Standards UL60950-1 2ndEd; IEC 60950-1:2005(2ndEd) ;EN60950-1:2006 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 10Mohms EMI Conduction&Radiation Compliance to EN55022  CLASS B EMSImmunity Compliance toEN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) >200000h (25℃, Full load) Dimension (L*W*H) 133*55*30mm Packing 49PCS/CTN, 15KGS, 0.04CBM Power Good Signal Working properly, port voltage: 3.0~3.5V(output current 0~1mA) Working abnormally, port voltage: 0~0.7V(pull-up resistor > 10K) Cooling method Cooling by free air convection NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttps://www.powerld.com. We provide high-quality LED power supplies for indoor and outdoor, and a variety of specifications and models of LED power supplies are optional, suitable for specific lighting applications in multiple fields.
  • VAT-UP300S-X-60L-A power supply
    VAT-UP300S-X-60L-A
    l   AC input: 90 ~ 264Vac l   Built-in active PFC function, PF>0.95 l  High efficiency, long life and high reliability l   Output protections: OCP/SCP /OTP l   Wide operating ambient temperature (-40℃~65℃) l   Operating altitude up to 3000m l   100% full load burn-in test l   Conformal coating l   No fan suitable for quiet environment l   3 years warranty MODEL VAT-UP300S-5-60L-A VAT-UP300S-4.6-60L-A OUTPUT DC Output 5V 4.6V Rated Current 60A 60A CurrentRange    Note 1 0~60A 0~60A Peak load 70A, last 50mS at 220Vac Ripple and Noise 25~65℃ ≤150mV 0~25℃ ≤200mV Voltage Adj. Range 3.3~5.10V Voltage Accuracy ±2.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2.0S (220Vac input, Full load) Hold up Time ≥5mS(220Vac ,80% load) Temperature Coefficient ±0.03%/℃ Overshoot <5% INPUT VoltageRange 90Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 90% 90% AC Current (max.) <5A Inrush Current (Typical) <60A@220Vac     Cold start Power factor >0.95(220Vac input ,full load) PROTECTION Over Power 325W~450W, Hiccup mode, auto recovery Over Current 65A~90A, Hiccup mode, auto recovery Shorted Circuit Long-term mode, auto recovery Over Temperature 115℃+5℃(detect on L4/C1);shut down, auto recovery after the temperature goes down ENVIRONMENT Operating amb. Temp. & Hum. -40℃~65℃; 20%~90%RH No condensing  (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Leakage Current Input—output: ≤0.25mA    Input—PG: ≤3.5mA (264Vac input, 63Hz) Isolation Resistance 10Mohms EMI Conduction&Radiation Compliance toEN55022, EN55024, FCC PART 15  Class B Harmonic Current Compliance toEN61000-3-2 Class D EMSImmunity Compliance toEN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs(25℃, Full load) Dimension (L*W*H) 208*60*30mm Packing 32pcs/CTN Cooling method Free air flow(PSU fixed to aluminum heat-sink of 400mm*400mm*2mm) NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 100uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. We cannot guarantee that the final equipment will meet EMC directives, Final product manufactures must be re-confirm that their product meets EMC directives. We provide high-quality LED power supplies for indoor and outdoor, and a variety of specifications and models of LED power supplies are optional, suitable for specific lighting applications in multiple fields.
  • EPS4860-1U Power Supply
    EPS4860-1U
    Main Specifications Model Output Voltage Range(V) Output Current Range(A) Ripple(p-p) (Rated Load, Width Limited20MHz) EPS4860-1U 53.5±0.25V 0—60 200mV Environmental Conditions No. Items Technical Specifications Unit Remarks 1 Operating Temperature -20—+55 ℃ Full load 2 Storage Temperature -40—+70 ℃ 3 Relative Humidity 5—95 % No condensation 4 Altitude 0-5000 m derate1℃with every 200 meters’ rising at 2000-5000m 5 Cooling Forced cooling,Draw air from the front and exhausts heat from the behind and this module has temperature-sensing timing function. Electrical Characteristics No. Item Technical Requirement Unit Remark 1、Input Characteristics 1.1 Rated input voltage 200—240 Vac Max AC input voltage 310VAC(static state),no damage to the unit for long time AC Input voltage range 90—286 1.2 Frequency 45—65(typical 50/60) Hz 1.3 Power factor ≥0.99 Rated input, rated load 1.4 Power transformation point 160-175 Vac The details refer to power transform characteristic curve diagram 1.5 Max input current ≤30 A Low voltage full load 1.6 Inrush current ≤30 A 220Vac 2、Output Characteristics 2.1 Rated output voltage 53.5±0.25 Vdc Input220Vac 2.2 Output power 3210 W 175—286Vac input 1605 W 90—174Vac input 2.3 Efficiency ≥90 % 220Vac/rated load current 2.4 Temperature coefficient ≤±0.02 %/℃ 2.5 Ripple and noise ≤200 mVp-p Oscillograph band width is 20MHz.Parallel 10u+104 Capacitor with probe 2.6 Starting up output delay ≤8 S 0VDCfrom rated input voltage to42VDC 2.7 Turn on/off overshoot amplitude ≤±5 % 2.8 Dynamic response Overshoot range △V:≤±5 % Load change at 25%—50%—25% or 50%—75%—50%, jumping rate is0.1A/us; and the jumping period is 4ms; the two half periods are the same Recovery time  △t:≤200 µS 2.9 Combined regulation ≤±1% 2.10 Current sharing imbalance ≤±5 % At the range of 50~100%load 2.11 The output rise time 500 ms Rated input, rated load 3、Protection Characteristics 3.1 Input under voltage protection point ≤85 Vac Can auto recover, 3.2 Input under voltage recovery point ≤88 Vac The return difference≥5V 3.3 Input over voltage protection ≥312 Vac Can auto recover Output Current0A(Test by AC SOURCE+ booster) 3.4 Input over voltage recovery point ≥302 Vac The return difference≥5V 3.5 Input over current protection              - - The AC input L and N wire have fuse 3.6 Output over voltage protection point 58.5—60.5 Vdc Constant voltage 3.7 Output current limit protection point          63≤I≤75 A Can auto recover 3.8 Short circuit protection Endure long time short circuit without damage and auto recover. The module will hiccup 5 minutes before it locked itself. 3.9 Over temperature protection Auto-recoverable when temperature is less than65℃ Powerld enterprises is specialized in switching power supply since 1991, obtained ISO9001 certificate in 2002, ISO14001 certificate in 2006.As a professional switching power supply manufacturer,Powerld can supply a broad range of power supply,we can not only supply our customers with high quality products,but also our best service and fast delivery time.
  • DG-U120SX Din rail power supply
    DG-U120SX
    Ø  Universal AC input range(90~264Vac) Ø  High efficiency up to 89% Ø  Built-in current limiting circuit Ø  Output protections: OVP/OLP/SCP/OTP Ø  Wide operating ambient temp (-20℃~70℃) Ø  Built-in DC OK function Ø  Can be installed on TS-35/7.5 or TS-35/15 Ø  100% full load burn-in test Ø  Suitable for critical applications Ø  Operating altitude up to6000m Ø  PCB with conformal coating Ø  Ultra-slim,45mm width Ø  3 years warranty SPECIFICATION                                               MODEL DG-U120S12 DG-U120S24 DG-U120S48 OUTPUT DC Output 12V 24V 48V Rated Current 10A 5A 2.5A CurrentRange    Note 1 0~10A 0~5A 0~2.5A Ripple and Noise  Note 2 0~70℃ ≤120mV ≤120mV ≤240mV -20℃~0 ≤240mV ≤240mV ≤480mV Voltage ADJ. Range 12~14V 24~28V 48~56V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <1.2S@230Vac ; <3.0mS@115Vac Hold up Time ≥10mS@115Vac; ≥20mS@230Vac    Full load Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac, 127Vdc-370Vdc FrequencyRange 47Hz~63Hz Efficiency ( Typical) 85% 88% 89% AC Current (max.) <2.7 A/115VAC ; <1.35A/230VAC Inrush Current (Typical) 20A/115Vac  ;  35A/230Vac  Cold start Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA (264Vac input, 63Hz) PROTECTION Over Load 10.5~13A 5.25~6.5A 2.75~3.25A Protection type: Constant current Over voltage 15~18V 29~33V 58~63V Protection type: Shut down, re-power on. Over temperature 100±5℃, detect on heat sink of power transistor; shut down O/P, re-power on. Short Circuit Long-term mode, auto recovery Operating amb. Temp. & Hum. -20℃~70℃; 20%~90%RH No condensing (pls refer to derating curve) ENVIRONMENT Storage Temp. & Hum. -40℃~85℃; 5%~95%RH No condensing Safety Standards UL508, UL60950, EN60950 SAFETY &EMC Note 3 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG: 1.5KVac/10mA. Secondary-PG: 0.5KVac/10mA. Isolation Resistance 10Mohms EMC Emission Compliance to EN55022, EN55024, FCC PART 15 Class B Harmonic Current Compliance to EN61000-3-2, CLASS A EMC Immunity Compliance to EN61000-4-2,3,4,5,6,11; heavy industry level MTBF (MIL-HDBK-217F) More than 500,000Hrs (25℃, Full load) OTHERS Dimension (L*W*H) 124*119*45mm Packing 24pcs/CTN,15.0Kg, 0.04cbm Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com. DIN rail power supply is a kind of switching power supply, which can convert unstable input voltage into stable output voltage. We can meet all industry standards of DIN rail power supply. Learn more, follow us, and leave us a message.
  • VAT-UP400S-X-60L-A power supply
    VAT-UP400S-X-60L-A
    l  AC input: 90-264Vac l   Built-in Active PFC, PF>0.93 l   Output protections: OLP/SCP/OTP/OPP l   Wide operating ambient temperature  (-40℃~80℃) l   No fan suitable for quiet environment l   100% full load burn-in test l   Long life and high reliability l   High efficiency up to 90% l   Conformal coating l   Low profile, 30mm l   3 years warranty MODEL VAT-UP400S-5-60L-A OUTPUT DC Output 5V Output Pre set voltage 5.0-5.10V (220Vac input, load 0A) Rated Current 80A CurrentRange    Note 1 0~80A Peak load 90A, last 50mS @ 220Vac Ripple and Noise 25~80℃ ≤150mV Voltage Adj. Range 4.15~5.10V Voltage Accuracy ±2.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2.5S (110Vac input, Full load), ≤1S (220Vac input, Full load) Hold up Time ≥10mS(220Vac input, 80% load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5% INPUT VoltageRange 90Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 90%(220Vac input ,full load) AC Current (max.) <5A Inrush Current (Typical) <80A@220Vac     Cold start Power factor >0.93(220Vac input ,full load);  >0.95/(110Vac input ,full load) PROTECTION Over Power 425W~550W, Hiccup mode, auto recovery Over Current 85A~110A, Hiccup mode, auto recovery Shorted Circuit Long-term mode, auto recovery Over Temperature 105℃+5℃(detect on Q1/D1 batten);shut down, auto recovery after the temperature goes down ENVIRONMENT Operating amb. Temp. & Hum. -40℃~80℃; 20%~90%RH No condensing  (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards GB4943-2001; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Leakage Current Input—output: ≤0.25mA    Input—PG: ≤3.5mA (264Vac input,63Hz) Isolation Resistance 10Mohms EMI Conduction & Radiation EN55022, EN55024, FCC Part 15, Class B Harmonic Current EN61000-3-2 CLASS D EMSImmunity EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) >200,000Hrs,full load Dimension (L*W*H) 235*60*30mm Packing 18pcs/CTN Cooling method Free air flow (Fixed to aluminum heatshink of customer’s system) NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 100uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. We cannot guarantee that the final equipment will meet EMC directives, Final product manufactures must be re-confirm that their product meets EMC directives. We provide high-quality LED power supplies for indoor and outdoor, and a variety of specifications and models of LED power supplies are optional, suitable for specific lighting applications in multiple fields.
  • DG-U240SX Din rail power supply
    DG-U240SX
    Ø  Universal AC input range(90~264Vac) Ø  Built-in active PFC,PF>0.94 Ø  High efficiency up to 87% Ø  Built-in current limiting circuit Ø  Output protections: OVP/OLP/SCP/OTP Ø  Wide operating ambient temp (-20℃~70℃) Ø  Can be installed on TS-35/7.5 or TS-35/15 Ø  100% full load burn-in test Ø  PCB soldering side with conformal coating Ø  Suitable for critical applications Ø  Altitude up to6000m Ø  Ultra-slim,70mm width Ø  Cooling by free air convection Ø  3 years warranty SPECIFICATION MODEL DG-U240S24 DG-U240S48 OUTPUT DC Output 24V 48V Rated Current 10A 5A CurrentRange    Note 1 0~10A 0~5A Ripple and Noise  Note 2 0~70℃ ≤120mV ≤240mV -20℃ ≤240mV ≤480mV Voltage ADJ. Range 24~28V 48~56V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <2S@230Vac Hold up Time ≥20mS@230Vac    Full load Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac, 127Vdc-370Vdc FrequencyRange 47Hz~63Hz Efficiency ( Typical) @ 230Vac 87% 88% AC Current (max.) <3A/115Vac ; <2.5 A/230Vac <3.5A/115Vac; <2.5A/230Vac Inrush Current (Typical) <30A/115Vac; <60A/230Vac  Cold start Power Factor 0.98/110VAC,  0.94/230VAC Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA (264Vac input, 63Hz) PROTECTION Over Load 10.3~11.5A 5.5~6.5A Protection type: Constant current Over voltage 28~35V 58~63V Protection type: Shut down, auto recovery Over temperature 100±5℃, detect on heat sink of power transistor; shut down O/P, auto recovery after fault condition removed. Short Circuit Long-term mode, auto recovery Operating amb. Temp. & Hum. -20℃~70℃; 20%~90%RH No condensing (pls refer to derating curve) ENVIRONMENT Storage Temp. & Hum. -40℃~85℃; 5%~95%RH No condensing Safety Standards UL508, UL60950, EN60950 SAFETY &EMC Note 3 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG: 1.5KVac/10mA. Secondary-PG: 0.5KVdc/10mA. Isolation Resistance 100Mohms EMC Emission Compliance to EN55022, EN55024  CLASS B Harmonic Current Compliance to EN61000-3-2, CLASS A EMC Immunity Compliance to EN61000-4-2,3,4,5,6,11; heavy industry level MTBF (MIL-HDBK-217F) More than 300,000Hrs (25℃, Full load) OTHERS Dimension (L*W*H) 70*124*127mm Packing 10pcs/CTN, 11.5Kgs,0.04cbm Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttps://www.powerld.com. We have a complete DIN rail power supply product catalog, providing reliable quality DIN rail power supply and affordable prices, fast delivery, customizable, please leave a message for consultation.
  • EPS4890 Power Supply
    EPS4890
    Main Specifications Model Output Voltage Range(V) Output Current Range(A) Ripple(p-p) (Rated Load, Width Limited20MHz) EPS4875-3U 48±0.25V 0—75 200mV Environmental Conditions No. Items Technical Specifications Unit Remarks 1 Operating Temperature -20—+55 ℃ Full load 2 Storage Temperature -40—+70 Powerld enterprises is specialized in switching power supply since 1991, obtained ISO9001 certificate in 2002, ISO14001 certificate in 2006.As a professional switching power supply manufacturer,Powerld can supply a broad range of power supply,we can not only supply our customers with high quality products,but also our best service and fast delivery time.
#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #